durodee:Finally someone who has walked the same path I am walking. I have a manual changeover switch, thanks for the suggestion. I have always felt that it is a grid backflow issue |
GloriousGbola:Valid point, my neighbor has never recharged the meter since I came unless she is using the wireless module to recharge. When I saw a house metered the other day, the official asked the houseowner for N20,000.00 to make the meter read slowly. I am now more emboldened to tear apart those boards and really check what is going on behind them |
My neighbor is asking that |I supply them power from my alternative to AEDC. Please recommend a cheap but functional meter that I can use to ensure that I can monitor their consumption if anyone has been through this situation before. Do we have it in the country or will I have to import? |
favouredbymercy:Will have to tear apart the board housing the fuses/breakers and changeover since those wires are all 1 color which makes it difficult to who what wire is which from just looking. I will also need to be this because of a less than intuitive arrangement of wires, in my former residence, from just looking one would know these are the incoming wires and these are the outgoing wires. It doesn't help that we also have 2 meters which sort of complicates the wiring setup. Will report back when I do |
gbadexy:Thanks. Lots of greys these days I missed that |
Gbadexy why do Nigerians seem to paint nearly every house white, off-white and cream? Tell me about the more common colors your clients purchase and the less common colors. I am trying to find out why because we are having an argument here and I would like the input of a professional and manufacturer |
SolomonGrundy:Apparently, the world has moved on, or more importantly we are more power hungry than we thought. Apparently, in the future 3.0kW will be the new baseline model |
Trippledots:Additional notes on the issue: Since turning off the distribution board (DB) didn't work, I'm trying a new approach to figure out this constant power draw. When my inverter is running the house, I'm seeing a continuous load of about 2kW. This happens even when the AC input is plugged in but there's no grid power. The same issue occurs when there is mains power, and it's simultaneously charging the inverter and the inverter is powering the house. However, the load drops dramatically—from 1.6-2.0kW down to around 0.20kW—if the mains power is charging the inverter but the inverter isn't supplying power to the house. My next step is to disconnect everything at the source, not just at the DB. I'll then connect each device or circuit back one by one while monitoring the inverter's power draw until I identify the source of the problem. I'm pretty sure this is a wiring, circuit, or device issue, and I'll report back once I've isolated it. One more thing: Breaking the AC IN connection to the inverter allows it to successfully run overnight, indicating that the issue isn't with the inverter's ability to operate on battery power. Instead, the problem likely stems from the AC IN circuit itself, or the inverter's interaction with the AC grid. This suggests a potential issue with one of the following: AC IN power source AC IN wiring or breaker Inverter's AC transfer switch |
topsy23:Rather than listing all the items, I'm trying a different approach since disconnecting the distribution board (DB) didn't work. There's a constant load of almost 2kW on the inverter when it's powering the house, even when the AC input used to charge the inverter is connected but there's no mains power. This situation persists even when there is mains power, and it's both charging the inverter and the inverter is powering the house. However, if there's mains power charging the inverter and the inverter is not powering the house, that is, the knife switch is in the mains supply position, the inverter load drops significantly from 1.6-2.0kW to around 0.20kW. I'm now going to use a new method: I'll disconnect everything at the source—not at the DB—and then reconnect them one by one. I'll monitor the inverter's power draw until I find the problem device or circuit. I'll provide an update later. This seems to be a wiring issue, a problematic circuit, or a faulty device on one of the circuits, and I believe this isolation method will help me find it. |
topsy23:- How many distribution board do you have in the house? 2 distribution boards (main house and self-con) - Where is the outgoing cable from inverter feeding? Outgoing cable from the inverter goes into the 3-phase 4 pole changeover knife switch, up is AEDC and down is the inverter - What are the loads on the inverter? all the loads of the house. Which are not turned on except as needed, because like right now the inverter does not even read up to 25% power draw Additional points, the house has an earthing problem, every metallic device shocks, and we were supposed to install a new earth today but the electrical contractor has rescheduled to tomorrow due to health issues. |
topsy23:I re-read your comments, I am addressing the bolded It doesn't charge but it starts doing a very abnormal discharge even with my loads disconnected until the breakers I discussed above are turned off |
topsy23:I have a Longi 3 phase meter, My neighbor uses a Longi 1 phase Meter. The Meter has L1 in and L1 out. L2 in and L2 out. L3 in and L2 out. Neutral in and out I tapped the neutral from the Neutral Out. I tapped the Live from the common Live Out. One has to be careful where to tap the Live and Neutral to charge the inverter so that the disco does not think one is trying to play a fast one and not pay bills, so I tapped the Live and Neutral after it exits the meter but before it enters the DB (house) and not before it enters the meter. In my previous residence I also tapped it at the RCCB just before the power goes into the DB, but the inverter was indoors close to the DB In my current residence, I am tapping the power closer to the meter just after it exits the meter and the inverter is now outside next to the meter. I am wondering if there is a house wiring problem because this situation only stops if I shut off the circuit breaker that is part of the meter or if I shut off the circuit breaker that I installed between the AC in and the inverter. Thanks. |
favouredbymercy:Your explanation makes the most sense. I have a Longi 3 phase meter, My neighbor uses a Longi 1 phase Meter. The Meter has L1 in and L1 out. L2 in and L2 out. L3 in and L2 out. Neutral in and out I tapped the neutral from the Neutral out. I tapped the Live from the common Live Out. I guess I need to change where the Live to AC in comes and revert. Thanks. |
I relocated and then I noticed my inverter no longer could hold a charge overnight. After some troubleshooting This is what we found: Whenever the power trips off, the power from the inverter seems to be coming back to the inverter to charge the inverter causing the inverter to run constantly at 50% load and the batteries to self discharge (that is without any applied load from my end) in less than 3 hours. Even after all appliances are switched off at the db level the 50% load remains. Has anyone ever experienced this? Initial thoughts was someone is tapping the electricity illegally but our investigation has eliminated this as a possible reason. Will continue troubleshooting tomorrow |
I and my technicians are troubleshooting an issue in which whenever the power trips off, the power from the inverter seems to be coming back to the inverter to charge the inverter causing the inverter to run constantly at 50% load. It does not help that they decided to use one color of wire to wire the entire house. I am not saying that that is the reason why we have this issue though. I have also decided to set up a brand new earthing installation since the earth I met seems to have issues. Hopefully we get a hang over it. The only way to stop that problem is to switch of the AC IN breaker between the mains and the inverter. I even went to the NERC website to take a look at the codes and regulations found these
|
bixton:On the core issue we share these same point of view. The differences are immaterial as they are purely semantics and pedantics |
GloriousGbola:So the companies respond to the market and the market drives demand and supply, An informed clientele will demand all the colors and the companies will not run at a loss providing all colors. No wonder everyone had just 1 color of 6mm the other day in the market |
topsy23:Likely because of the predominance of the wrong practices. |
bixton:This was the prompt, what was your own prompt? Define cutting corners In my line of business, we learn a lot by comparing definitions. I am also aware that people who study scripture benefit a lot by comparing the same verse in different translations. Do you realise that not considering more than 1 definition you leave yourself at risk of being considered close minded? If there is something wrong about the definition from my own AI, critique it and point it out. Let everyone learn. I'm lazy. I cheat once more by answering your first question with AI. Using the same color for both terminals (positive and negative) does not reduce the quality of the electricity itself, assuming the cables are of the same size and value. The electrical current will flow just as it should, with no degradation in power or signal. However, it is an extremely dangerous and non-compliant practice that creates severe risks for anyone working on the electrical system. While using a single color for both terminals doesn't affect the physical quality of the electricity, it creates an extreme safety hazard and is a practice of "cutting corners" that no professional would ever endorse. |
twinskenny:I deeply appreciate your input |
GloriousGbola:I use 6mm from my inverter to the db. Thanks very much |
Please what is the correct wire gauge to run between the pole and the house if the house uses a single phase and will not run appliances higher than 1 AC and 1 deep freezer? is it 6mm or 10mm or 16mm? So I can advise my friend whose house has just been metered? Thanks |
bixton:Here is the definition and additional notes on cutting corners from my own AI: "Cutting corners" is an idiom that describes the act of doing something in the easiest, cheapest, or fastest way possible, often by neglecting proper procedures, standards, or quality. This shortcut typically results in a lower-quality outcome, potential risks, or future problems. Here's a breakdown of what it implies: Sacrificing Quality: The primary characteristic of cutting corners is a reduction in the quality of the work or product. This is done to save resources. Saving Time, Money, or Effort: The motivation behind cutting corners is usually to complete a task more quickly, with less expense, or with less physical or mental effort. Ignoring Rules or Standards: It often involves deviating from established guidelines, best practices, or safety regulations. Potential for Negative Consequences: While the immediate goal is efficiency, cutting corners often leads to negative repercussions such as: Poor performance: The final product or service may not function as intended. Safety hazards: In critical areas like construction or electrical work, this can lead to dangerous situations. Durability issues: The item or system may break down prematurely. Increased future costs: Problems arising from shortcuts may be more expensive to fix later. Legal or ethical violations: In some cases, cutting corners can be illegal or unethical. Origin: The idiom likely originates from the literal act of taking a shortcut by "cutting" across a corner instead of following the proper, longer route. While this might save a little time or distance, it could also lead to damage (e.g., trampling grass) or an increased risk of accidents. In essence, cutting corners is about prioritizing expediency over thoroughness and quality, often with detrimental long-term effects. So hope this helps the discourse |
bixton:Warning: this is going to be a long read! I think that I will disagree with you. Because I do not have the time to draft a response, i asked AI to help me explain why using one color of wire for total house wiring is indeed cutting corners. First, I asked, What is wrong about using one color of wire to wire an entire house? Using only one color of wire to wire an entire house is dangerous, against electrical codes, and makes troubleshooting extremely difficult. Safety and Code Compliance Electrical wiring color codes exist for safety. Different colors are used to identify the function of each wire: hot wires that carry current, neutral wires that return current to the source, and ground wires that provide a safe path for stray electricity to prevent shocks. Without this color-coding system, a person working on the electrical system—whether it's the homeowner or a professional electrician—cannot easily tell which wire is which. This drastically increases the risk of touching a live wire, leading to electric shock, burns, or even death. The National Electrical Code (NEC) in the U.S. and similar standards internationally mandate these color codes to ensure safety. Using a single color would be a violation of these codes and could cause an inspection to fail. Troubleshooting When an electrical problem occurs, such as a tripped breaker or a malfunctioning outlet, the color-coded wires provide a universal language for diagnosing the issue. An electrician can quickly identify the purpose of each wire at a glance. If all wires are the same color, every wire would have to be tested individually with a multimeter to determine its function, which is a tedious and time-consuming process that can add significant cost to a repair. Common Color Codes While a single color is a major issue, it's also important to know the standard colors. In the United States, common residential wiring includes: Black and red wires for hot wires. White or gray for neutral wires. Green, green with a yellow stripe, or bare copper for ground wires. The video below explains the significance of different wire colors in a home's electrical system. https://www.youtube.com/watch?v=Far1jkipwdc Next, I asked Would it be correct to say such a practice is cutting corners? Yes, using a single color of wire to wire an entire house is a classic example of "cutting corners" and is considered an unsafe, non-compliant, and dangerous practice in the electrical industry. ⚠️ It's a huge risk that can lead to severe consequences. Why It's a Dangerous Practice Safety Hazard: The primary function of wire color coding is to identify the purpose of each wire instantly. Without it, you can't tell which wire is live (hot), which is the neutral return path, and which is the ground safety wire. This puts anyone working on the electrical system—including future homeowners, inspectors, or electricians—at a high risk of electric shock, electrocution, or starting a fire. Code Violation: Electrical codes, like the National Electrical Code (NEC), mandate specific color codes for wiring for safety and uniformity. Using one color for all wires is a direct violation of these codes. A property wired this way would fail inspection, making it difficult to sell or insure. Troubleshooting Nightmare: When an issue arises, such as a short circuit or a non-working outlet, an electrician uses the wire colors to quickly diagnose the problem. A system with a single color would require extensive, time-consuming testing of every wire to determine its function, which increases repair costs and prolongs the outage. Properly color-coded wiring is the standard for a reason: it's a critical safety measure that makes electrical systems safer to install, maintain, and troubleshoot. Cutting this corner is not just a shortcut; it's a serious hazard that can have deadly consequences. You can see an electrician discuss the importance of wire color coding in Electrical Wire Color Coding Used By Electricians. This video explains how electricians rely on color coding to understand a circuit and ensure safety. https://www.youtube.com/watch?v=LhZcWykPWQc Conclusion my words not AI this time around I am a hobbyist. I fix electrical issues at home, I have even studied a bit of electronics so I can troubleshoot circuits on my state of the art in its day vintage amplifiers (Kenwood KA-907s). I even got the service manuals for all of them, so I know that color coding was done for standardization so anyone can just look at a circuit and understand in minutes what the circuit designers built, as far as I am concerned, using one wire to build an entire building's electrical circuit is electrical heresy and blasphemy and everyone who does that should be sent to the gallows as they have no business playing with electricity and its circuits. What twinskenny said is entirely plausible |
@gloriousgbola @twinskenny @bixton Today I was privileged to see a house being metered. The problem seems to be that even the representatives of the electricity distribution authority (AEDC) do the wrong thing. They used black wires for both the live and the neutral. It was a one phase meter by the way. I also noticed that the housing contractor (it was a house in an estate built for civil servants somewhere in Abuja) used red wires for both the live and the neutral for the wiring of the house. As I watched closely, after installing the meter, he taped one of the black wires likely to indicate that it is live wire. Last week one of the companies in my office building installed a 5kva Felicity inverter and 7.5kva lithium battery. The installer used red wires all through. So this is where the problem is. The contractors, the electricity distribution company, the home owners who do not know any better and nearly everyone else is cutting corners. Unless you know better, because whenever I want to buy wires for installing my solar panels, I insist on double wire with different colors, and when I want to wire a house I insist we buy 3 different wires, red, black and green. The installers often say no need for the earth, I insist on earthing everything. I noticed that in my own house (the new house I spoke of in my last post) that has a three phase meter, the wire from the pole is black but has all the proper color markings for all the phases, neutral and earth. But it is when the wires from the meter leave into the house that the wiring is done wrong. This is why one needs to know a bit of something and not leave every fine detail to contractors. |
bixton:Excellent suggestion that will save me a ton of cash, those cables are pricey. Thanks. Especially as the property does not belong to me! |
GloriousGbola:Thank you! |
GloriousGbola:I moved to a new house and all the wires from the pole to the house are black. All the wires from the meter into the house are black. All the wires to and from the phases are black. The wires into the ELCB is black, live and neutral out of the ELCB into the DB are red. I went to market yesterday to buy 6mm wire and they say they have only red, I said I want black and white, they said use tape to make the red black that they have only red. I think that for my sanity I will keep looking for the wires of the proper colors and rewire the wiring. I literally had to go to youtube before I could connect my inverter to the house because of this nonsense I will also replace the ELCB with my own RCCB. I have seen it trip off in response to an overload that caused a fire and also trip off when water got into one of the circuits of the freezer wires, so I am a convert through and through. The house even has an earth fault and I wonder how easy it is going to be to troubleshoot |
Excuse my ignorance but it is ok to use one color say red or black to wire an entire house? |
gbadexy:Please what is the current price of your 20L pail of putty? Do you have someone who knows how to apply it in Abuja (not someone who has to travel here)? Asking because most people opt for cement or pop application which means they might not know how to apply it properly |
favouredbymercy:If it trips off, I allow the battery to discharge a bit through usage and then you can turn the breaker on again, failing which you will simply run down your battery. Or discover that the remaining runtime has been severely limited |