Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 2:58pm On Jan 16, 2018 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 12:11pm On Jan 11, 2018 |
efuro: My oga, you're on point, Energy efficiency is the key to successes in R.E. However, some of us are discouraged by (not necessarily cheap) fake/poor led bulbs whitewashing Nigerian market. As a matter of fact, I have many energy bulbs waiting to replace unreliable led bulb that goes out. Thus requiring more power to run - more power to harvest. You are very correct! What I am doing now is that I have bought 3 different types of bulbs (all in 3.3 w). Two are still serving (8 months), one just lasted 6 months. I use them for my security lighting, which stays on for 11 hrs each day. When I conclude on my tests, I will recommend it. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 12:03pm On Jan 11, 2018 |
bigrovar: I use microwave, energy efficiency does not mean live like a monk. Juo uses electric Iron. Energy efficiency is about doing more with less.. If you have the money and AC is a priority then by all means but at least save energy in other areas. For me and I know many do not have the luxury here.. Energy conservation is at the back of my mind .. its one of the most important parameter I choose when I want to pick an apartment. Well ventilated windows. In the construction of my house I made sure to use large windows that are located to the north side to reduce impart of the sun. Colour of your roof, creation of roof attic ventilation to prevent build up of heat in the root attic which then sips into the house via the "man hole" I was going to use hydraulic compressed bricks due to their excellent thermal resistance but lack of know how in my area. But I intend to plant flowers and trees that will help in keeping the house cool requiring less need for AC. Worked on a design of the plumbing of the house so that grey water from the washing machine, kitchen and bathroom can be channelled into drip irrigation for the house trees, garden and flowers. will help to reduce my energy footprint.
Lastly, I made sure the kitchen used white tiles so that a 6w LED bulb will provide sufficient illumination due to the whites bouncing lights amplifying it's intensity. 90% of outdoor lights are small solar motion controlled lights are are dim by default and brightens when there sense motion. They come with their own batteries and tiny solar modules and are as such disconnected from the house. They come on at night and go off automatically.
All the above I did to ensure I use less energy in the house. It doesn't mean I won't have operate my washing machine or microwave on solar. but at least I spent some time in tweaking and optimising the energy needs. Good points my brother. You just save me a lot of grammar by composing this! Building and positioning of your house very important. The hight of each room and kitchen is paramount. I watched a video back then of an energy efficient building, that was the turning point for me. Since I moved into my house (going to 3yrs) I can't remember the last time I used all my standing Fans! Never switched it on cos of the room(s) heating up. In fact, I have to battle cold during the raining and the current seasons we are in (I need to block my windows with mattresses). During the heat period, I open two windows out of three in the master's bedroom, by 1 am, I would need to stand up to close the windows. So, you need to be very smart when going green/off grid. Except you intend selling back to the grid, then you can start generating 'crazy KW'. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 4:20pm On Jan 10, 2018 |
All my security light bulbs (11) is just 36.3 watts (3.3 w each) and quite bright too. The highest bulb wattage in the house is 10 w, just that one, the rest ~5 - 7 w. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 4:12pm On Jan 10, 2018 |
JUO: if you tell them, they don't need huge battery bank to enjoy 24/7 light it looks as if you don't know what you are saying. Imagine one person generating 18kwh in a 3-4 bed room apartment. What for, are you selling energy? Energy conservation is the only solution Lol! That is what I call; Ile se bread fa  |
Business › Re: How To Make 100k Profit Monthly As A VTU Airtime Vendor by Oshomo12(m): 2:53pm On Jan 07, 2018 |
Interested toptomeee@yahoo.com |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 4:35am On Dec 15, 2017 |
Barezzi: A better option might be to keep the fridge door open  I am considering this option seriously!  Note: No fund yet to do what Pranil did and man must cool down fa! |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 10:17am On Dec 08, 2017 |
amen69: Hello house. Please can anyone help me with this issue. I have a Solar system setup made up of 2 panels 130w and 150w, 2 batteries of 100A each, 2 solar fans which uses DC current and light bulbs for all my bedrooms, sitting room and kitchen. The engineer run a separate connection for the system meaning I can be using both PHCN and the solar concurrently. The guy cut off Inverter. Then for me to watch TV, he said I need a converter box to convert the DC to AC. He brought the first one of 500w but could not power my 42" LG TV. He brought 1000w but still could not power my TV. Then he said I should go and buy solar TV, and I can't go for that since I will still have to power other equipment with the solar system. Any suggestions for me? Double check if your TV is working using normal Phcn source. LG Tvs( I no de near that one again!) |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 10:30am On Dec 02, 2017 |
Hello house, anybody has an idea where I can get 100ah 12V flooded battery? Someone asked me to get it for him. I have looked around and couldn't find one yet. |
Education › Re: A Nairalander Convocating At University Of Ibadan Today (pics) by Oshomo12(m): 9:46pm On Nov 13, 2017*. Modified: 10:10pm On Nov 13, 2017 |
UI convocation today or Wednesday(15/11/2017)? Cos someone told me today to come for his' on Wednesday. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 5:56pm On Oct 10, 2017 |
Dam5reey: Sell the 150W and buy 2 200W 24 volts panel my 2 cent, I think I posted how to add mismatched panels sometimes ago This is the most preferred wayout anyway. It's saves one lots of headache. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 5:52pm On Oct 10, 2017 |
Valto: i cant get the pix of the 150w for now Ok, but the spec of the 150w is important before one can advice on the connection config/buying of the one panel needed. Secondly, what is the max voltage for your Mppt controller? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 1:13pm On Oct 10, 2017 |
Valto: pls house. i have 2pcs 200w(sunshine) and 1pc 150w(focus) mono panels. i want to buy one more panel to make it 4 pcs, to be connected to a 30amps mppt cc with a 24v pure sine inverter. whats the best option for me? should i buy 1 more 150w or 200w panel? whats the best series connection for me? Upload the specs of the two panels, stating all voltages and the currents u see at back of the panels. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 9:12am On Sep 06, 2017 |
earthrealm: HAHAHHAHAHAHAHAHAHAHAH!, in this buhari era, kai..this man no like me, though you have a point, max instantenous harvest i hv seen is 1290w and abt 41amps , so its likely the additional 2 x 250w panels will generate additional 10 to 13amps....since my placement isnt optimal.
would be very glad if i can revive these batteries, am hopeful i would. think most of the damage was done this present rainy season/bad weather, since in good weather i generate 7kwh, and use abt 2.5kwh daily, so within 3days, the excess 4.5kwh x 3 would try to keep the batt bank happy I pray u get those batteries back up and running. That's y most of my calculations I use maximum of 3hrs of insolation(when budget is tight), ordinarily, I use 2hrs. The reason is just for this period. The sun is not smiling this time. Add d 500w as pointed out by JUO. It will save u around this period next year, good luck. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:37am On Aug 18, 2017 |
Saipro: We're luckier in Ilorin. The sky was overcast throughout yesterday as it rained/drizzled from the previous night all the way to yesterday night giving me just 3.1kW. Still got My least sunny day this year has yielded about 2.9kW (3kW of panels). I've had as low as 1.3kW on some days (paradoxically very sunny days) due to minimal use, not lack of sunshine.
My polycrystalline (not to be confused with the older but now distinct multicrystalline) PV modules seemingly now outperform my monocrystalline modules in low light conditions. Replicated the results over the past year. Ilorin is a good place for solar even around this period. Anybody complaining should come to Akure and see worse! I am thinking of small wind turbine for this period (around 400W). The ones I ve seen so far on aliexpress, the feedback not good (imagine 400w not producing even 100w). |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 3:21pm On Aug 04, 2017 |
battleaxe: @house, Also, is it typical to loop two separate solar arrays together and terminate just one cable instead of two for both arrays on the breaker?
I have my thoughts on these but looking for individual experiences on this.
Thanks house. I want to assume that u are talking about two or more strings( eg, 2*250 watts in series make a string. And you want to connect two of this in parallel and terminate this on a single breaker?) pls don't do that, use a breaker for each string. That's the function of a combiner box, get one or improvised. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 6:31pm On Jul 27, 2017 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 7:07am On Jul 27, 2017 |
GeorgeD1: dunka, my candid opinion is to get an independent tower to install your water heater. however, if you insist on installing it on your aluminium roof, make sure you consult your carpenter for proper reinforcement of your roof polines and beams. i had similar thoughts like yours when i was going to acquire my own 300l but after it arrived and i had it assembled, i was like "wow!" "there is no way i'm going to place that massive frame filled with water on my roof!" so, i instantly began discussions with my welder for a separate water tower. Can you share pics of the installation? I would love to have an idea of how it looks like, thank u. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 6:29pm On Jul 26, 2017 |
damola1: I am ikeja. Off oba akran. Right now. I need to buy or not buy. Should I buy? After you have confirmed the shipping cost as pointed out by other guys. Pls do buy it, though I am not anywhere near Lagos. I am sure u will see people to help u out here. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 12:42pm On Jul 26, 2017 |
@Demola1, state ur location so that any pro close to u will help u out once u have those batteries in place. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 11:21am On Jul 26, 2017 |
damola1: ----------------- The seller stated:
These LiFePO4 need to be run with a BMS (Battery management system) . If you haven't worked with lithium cells then it would be better to use Lead Acid Deep Cycle Batteries which are more forgiving to accidental mistakes.
-------------- Me, I don't know anything about BMS. But do I know anything about inverter before? what we need is un interrupted power. so, am sure if need be , one can overcome it, is this something to worry about?
Normally, as long as I put my battery in a ventilated area. and make sure it works fine. Is there any other factor to work on? OR do I need to engage the services of a local professional? in installation and on going usage. Do a YouTube search on Lifepo4 BMS, also read about it. This is very important if you intend to use this battery chemistry. It's the best for now and also expensive too. So you cannot afford a mistake on them. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 7:36am On Jul 05, 2017 |
foonshur: Who made this inverter? Sorry about ur batteries, I can't just imagine it. For this Buhari's time! The maker of that inverter should be shòt. Next time when u need to test an inverter, do equip urself with a clamp meter, test both the voltage and current(charging). Pls avoid this mistake, it is too costly. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:39pm On Jun 23, 2017 |
DMerciful: My LiFeO4 is performing excellent. My confidence level on my batteries is solid....still counting time sha What is the spec of ur LiFePo4? That's the battery I am saving toward. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 7:13pm On Jun 21, 2017 |
Saipro: That's why RE is no joke. Takes lots of planning and serious consideration. Money doesn't always come easy but time is about the most expensive currency we humans deal in. You have to do a delicate balancing act between your needs and desires. My own recommendation: if you want more time out of your batteries, size them appropriately or get the right chemistry type. I totally agree with you. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 7:04pm On Jun 21, 2017 |
tivta: Simpliphi has a dod of 80% with over 10000 cycles but cost about $3800 per 64amps at 48volts I beg no talk this battery! Na to sell my landed properties before I can afford 200ah.  |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 11:55pm On Jun 20, 2017 |
DMerciful: What he meant is overall at 50%, you draw out more returns on investment that at 30%. He is a very good economist however sometimes availability outweighs cost! For instance d 30% discharge plan gives more longevity before replenishment as opposed to more 'harvest' from d system. All this solar wahala tire me, can't we just get a perfect battery? Batteries are the most expensive part of the system. I need a battery @90% DoD and 15000 cycles!  |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:53pm On Jun 20, 2017 |
Ferdiwar: The logic is that @ 30% you can charge and discharge it 2750 times while @ 50% you can charge and discharge it 1750 times.
That means that while discharging it to 30% the battery lasts longer than when you discharge it to 50%. Thank you. More power less life span, less power taken out of the batteries more life span. Hope this is logical? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 7:32pm On Jun 20, 2017 |
Dam5reey: So technically it better to discharge 50% than 30% of battery capacity 
@30% I will only get 165,000AH from my battery.. whereas @50% I will get 175,000AH.
Abeg what's the logic here? No! Technically it's better @30% you get longer battery life than @50% |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 2:22pm On Jun 19, 2017 |
pranil: Even the charts differs one shows 100 cycles at 80 % dod and one shows 500 cycles at 80 % DOD 
Exact cycle life is important when calculating the battery size and load requirements
Wbr
Anil Yes, one is from a research lab and the other is from the battery data sheet ( company's claim). |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 5:31am On Jun 19, 2017 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 5:23am On Jun 19, 2017 |
pranil: What is the cycle life on 80 % and 50 % DOD . No info on the website of the company I want to believe that these batteries are lead acid chemistry, so same cycle life applies to 80 and 50% DoD.
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 11:22pm On Jun 13, 2017 |
emmaniche: Please help house.
Can a 5Kva inverter support 16X12V/200AH batteires, how long can it take to chargethe whole batteries? Ideally, max number of strings should be 3. If u have a 48v inverter. 1 string will have 4 batteries to make it 48v. So 3 strings in parallel should contain 12 batteries. Others may have a different view though. What is ur input voltage for the 5kva inverter? |