Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:56am On Mar 09, 2019
earthrealm:
errrrm think, he needs to state his load, and probablly charging pattern/frequency etc. and he said 6months..not 2months....


grin grin@kiekie..savage you are!!.. posting your WE BUY DEAD BATTS ADVERTS immediately,..lolz..guess na coincidence, grin grin grin
Two or three ways a battery cell could go bad(shorted cell); 1. Battery is old and shading materials(this settled at d bottom and eventually brigades d cell) 2. Sulphation due to poor charging algorithm, this takes time, not within 6months. 3. Most important one(for his case) manufacturing error(shit happens).

Don't mind kiekie jor! He wants to give the battery funeral asap(inevitable eventually)
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 5:55pm On Mar 08, 2019
bodeface:
Good morning house.

Please, I need help one of the 4 AGM 200AH (make is hidden for now as I haven't discussed with the seller) I bought about six months ago is giving 10.5V while the rest 3 is giving 12.6V. Desulphator is connected and correct battery setup performed on the Solar charge controller.

Please what are the causes and is there any remedy to salvage the situation.

All info / help appreciated. I will also reach out to the seller. Will update the house.
The battery probably have one or two cells shorted. Remedy, none(get it replaced if there is warranty on it).
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 5:43pm On Mar 08, 2019
Braaad:
Hello good people of this forum, please, I urgently need a link to buy Tesla power wall here in Nigeria.

I've tried some companies including PSC solar, they don't have in stock.

I would really appreciate a link to buy it here or to get it directly from the company abroad.

Any help is highly appreciated.

PS: if there is any other alternative of comparable quality to the power wall, I'd like to know.

Thanks in advance
Contact solardepot in Ibadan, he has BYD lithium batteries, and very good product too.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 6:12pm On Mar 02, 2019
ojeysky:
Ah! I used FedEx based on the experience shared by duwdu who used FedEx as well and got delivery of the same inverter (just that mine is 3kva). Now I am worried!!!
This people and their hopelessness, duwdu should have info on the payment. Kindly let us know how much u pay at the end. Good luck!
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 4:15am On Jan 17, 2019
Malevonent:
is there any more wrong in runing 2 x 250w panels in series to an mppt charge controller on a 48v inverter, my instaler is insisting there is no harm/loss of charging potential, i feel a 3 x 250w series setup is better, so as to have enough headroom to charge the smf batts.

what do u guys think?
You can be right IF and Only IF your mppt max voltage is 150V and not 100V confirm that first.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 6:55pm On Jan 16, 2019
Trippledots:
I just stumbled on this post. I want to ask a question.

I am building a very small system....i am rarely at home during the day and so i feel my battery(s) will charge well during the day.

Panels are;
3pcs of 100w, with one salvaged 300w panel all in parallel (its a 24v panel tho, why not just add it rather than leave it idle).

200ahr battery; and a an average load of 150w through the night (max 250w briefly).

Since im not always at home during the day, can i get/add a very small chest freezer to my system? any idea of any easy-to-get brand? Say 100-200ltrs and very efficient too.

Hope my question isnt long and winded.

Thanks
You need to answer so many questions,
NO U CAN NOT ADD IT! (I am at home will not work o)
From d little details u gave. U have a 12v 200ahr and u re pulling 12.5a already(150w) instead of 10a(120w max, C20 rule). U now want to kill d donkey by adding small chest freezer. How long does the battery last over night?. Under 50%Dod, u can't do more than 7hrs, except u have started killing the battery already.

Note: why put a 300w panel in parallel with 100w panels, are u an installer?
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 4:18pm On Jan 15, 2019
mank1234:
Another huddle: The seller is saying they ship from Taiwan. That if the shipper is receiving in China, that she'll have to pay tax in China. Any idea of Chinese tax rate?
I want to belief that d shipper should give u that info. Have you discussed with him on this, when he gave u quotation, is he aware that it's coming from Taiwan?
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 7:51am On Jan 03, 2019
mank1234:
Between mains and inverter.
If this is the case, my brother, in Nigeria with phcn, you MUST use a stab. Otherwise, garbage in, garbage out. Secondly, your inverter will not charge the batteries if mains is lower than~170v.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 5:07pm On Dec 22, 2018
pheleix:
Was of the thought it would drop to say 70 to 80% soc.
More calculated, practical and experience inputs please.
Thanks
My guy, Dam5reey has given u both practical and theoretical end of your batteries, why ask again? undecided
@ 24v 200ah u re supposed to pull 10a savely from ur batteries, u re now talking of pulling around 84a! After such successful pull, d life of ur batteries will never remain the same. I may be wrong though, since this is a DIY, kindly do that experiment on ur batteries and report back to the house, who knows u can be right.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 10:00pm On Dec 21, 2018
ojeysky:
It didn't indicate the wattage, they just have various number of LEDs, do you know the one equivalent to 5watts?

Thanks
Sorry, I forgot to add
It is about:
56LEDs -- 4.5w
69LEDs -- 5.5w
72LEDs -- 6w this ones measured around 5.5w on my meter.
The least leds(24, is around 3w)
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 2:30pm On Dec 21, 2018
ojeysky:
Can I know this low watt LED bulks, the least I have been able to get is 15w AKT bulb. Where can I get the lower wattage and are they bright enough?
Look what I found on AliExpress
https://s.click.aliexpress.com/e/eij95GM

I have used them for up to 2yrs.
Note: I always choose the cold white type, it's brighter.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:43am On Dec 19, 2018
pitodenz:
Thanks everyone that contributed
PV max current is 60A and my configuration is 40.5A max
So on Sunday I went back as early as 8am to observe I also contacted Mustpower company about the issue which they told me that it never happened before but as well render some assistance so I was able to resolve it after running a factory reset and setting battery full charge to 58v which match the AGM in the manufacturer manual
There was no cut in charge again so I decided to monitor the process all Sunday
As am speaking the client told me he run on AC all night
Good to know that its resolved.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 10:17am On Dec 18, 2018
Morning guys,
I just took delivery of the Fangpusun replacement CC from DHL today. No charges or what so ever. Maybe because it was tagg a girt. I will update the house to what led to this. So @ oga Niyi, no be only you dey enjoy super customer service o, we Fangpusun team too dey represent. Wonderful customer service and they keep to their warranty!
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 11:48am On Dec 17, 2018
nonoski:
Yes i have increased capacity from 4.5kw to 6kw by next week i will add the final panels which will bring it to 6.75kw.

But i'm not bothered about the absorption stage coz from Monday morning to Friday evening we usually have 100% lite from PHED so the batteries remain in float mode.
Basically the solar system works starts working from Friday evenings.
Better then, all correct!
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:29pm On Dec 16, 2018
nonoski:
Observation Nr 1:
Avoid the temptation of mixing old and new batteries u will eventually regret it.

Observation Nr 2:
Try as much as possible to have a battery voltage indicator connected to all the batteries so u can always see the voltage of each battery and know when one is under performing so as not to drag the entire bank along with it.

Observation Nr 3:
I am still wondering if one can truly sustain on solar. (My saving grace is that when PHED lite is on it can stay as much as 2 weeks without blinking but when it goes off it takes another 1 week for it to be restored.)

In Port Harcourt during the raining season harvest was very very low. My 4.5kw solar array usually puts out about 5kwh – 8kwh on good days and as low as 3kwh on bad days.

Initially I tot there was something wrong with my connections but on some VERY rare occasions when the sun shines all day it puts out about 14.5-15kwh with instantaneous power at average 3.4KWp - 4.1KWp.

Since the coming of dry season here in PH, my KWp has reduced to Max 2.6KWp for a 4.5kw solar array but the daily harvest moved up to about 14.5+kwh.

I am a little confused coz I was hoping that my KWp will remain high now that the sun is here

Pic 1 & 2: are from today and yesterday

While

Pix 3 & 4: are from early November during tbe raining season.

Is it safe to assume that Kwp is better during the racing season than during the dry season?
What a beautiful setup and a wonderful journey so far, it is not easy o.
From the 4pix u uploaded, I could only see that ur batteries enter absorption stage 1 out of 4 times, no float at all. is this a regular thing?
If yes, then u do not need any more panels, the ones u ve is okay. What you need now is ENERGY CONSERVATION not generation. Bigrov, where are you?
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:14pm On Dec 16, 2018
mcTrinity:
Also, most times, the suppliers doesn't help matter. If a client demands I supply him 12 batteries. if 12 batteries of same brand are not available at that moment, I'll simply tell him to either go for 8 or just wait.

But then, I've discovered that even most of them don't know any single nothing. They just know "pay and I'll supply". whether you're buying 5 different brands to use on one bank, they don't know the consequences

yet, even those that are fully aware of the consequences will still go ahead with the transaction... after all, what's their business. tomorrow when you start complaining, they'll put all blame on you. that's when you'll know that asking for warranty from our dealers is like asking PMB to resign...

It is well o
My brother, this country na so so gain gain, even if it's going to destroy my neighbors, I don't care! Just for me and my family to be okay, another's can die. All we care about is money, which ever way u make it, not our business(sadly our religions support that now). I discovered recently that the common 2.5mm2 single core wire they sell now is not upto 1.35mm2. How? I want to get a 6mm2 wire, my customer told me to go for 4mm2 one particular product; he says it's better than that 6mm2 I asked for. I was confused and I bought the 4mm2. His reason was that, in meters, the one he recommended is better, but I don't believe that. I bought a little piece of the other one. Got home, brought out my micro meter screw gauge and measured the wire diameter to be sure. I discovered that the 4mm2 diameter correspond to the actual 4mm2, while the 6mm2 diameter correspond to around 3.5mm2.
So, must of this guys selling this stuff know nothing about what they re selling. And the people that do know are in one stupid office chasing after papers(I am not excluded from this). Mixing of batteries of different maker: No No No No.... That little internal resistance difference will sink a whole ship! It's just physics my brother.
nonoski:
grin
If only u knew the nr of days I soaked Garri to be able to afford 12 batteries (N1.3m) within 6 weeks.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 1:51pm On Dec 16, 2018
@NiyiOmoIyunade thanks so much for the diagram, I trust u will definitely respond grin


Note: I just noticed that, this is the way I wired most of my batteries bank. For the 24V setup, I use just one balancer and 2 volts reading indicators instead of 4.
Properties › Re: Legal Advice Needed, My Landlord Just Brought Quit Notice For All Tenants. by Oshomo12(m): 9:51am On Dec 16, 2018
My guy, u re getting too comfortable in another man's house! I have a principle that help me in life; NEVER BEG/DRAG ANYTHING WITH A LANDLORD. If you tell me to move, I initiate moving mode immediately, even when u come back to ur senses(landlord), I move. This has helped me in life, after facing three idiot landlords, last one, I move to my own small apartment. It never going to be easy though, but it will pay u in the long run.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:53pm On Dec 15, 2018
pitodenz:
The PV voltage is range 64-145v for 48v system which am installing
I have gone through the manual the only thing I couldn't find is where to select battery type as it's on SLA by default and am using AGM battery
I even brought another inverter same product from my shop n test it in the same client house it still cutting off charge from solar array
The electric charging system is perfect but something keep disrupting the mppt system
I have contacted Mustpower factory in China but I have to wait till Monday to get assistance from them
Hello, what is the maximum input current for the inverter(pv section, we know d max pv voltage is 145v, u need to know d max input current too)?
Go back there and start with 3*2 config and see what happens. If it works fine, go to 3*3. My guess is, maybe 3*4 config current is high for the pv input of d inverter. Good luck.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 4:23pm On Dec 14, 2018
olaade21:
Sir, still waiting for the diagram and more details. Trust you have been busy and actually forgot to upload it.
@NiyiOmoIyunade upload now! angry

I don't know you for hoarding valuable info fa! Do the needful
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 4:15pm On Dec 14, 2018
DMerciful:
Feed us back on the outcome. I only use FedEx to avoid duty
I will do that bro. That's very nice then, plan B is established for next transaction.
dejidotun2000:
No charge whatsoever.
It was delivered to my home address.
Better then, thanks for sharing

UPS got me very 'afraid', I try to avoid anything to do with those guys! Post office or nothing principle was activated over two years ago.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 9:58pm On Dec 13, 2018
dejidotun2000:
I have successfully received a Fangpusun
controller sent via DHL
Thank you for that reassurance. It was sent yesterday via DHL.
How was the charges, hope no DSS, FIRS, police et al issues? undecided
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 12:56pm On Dec 12, 2018
Alejob:
Bros if you carry out due diligence but testing appropriately.....the probability of getting value for money is high. Sometimes the only option just a fairly used battery as funny as that may sound!
out of 10 used batteries buyers, how many know how to carryout this due diligence test? will the seller give you/them room for that test? by the time you factored in all this and that, most buyers will just end up paying for crap batteries. so my brother, used batteries is not for the general public, it is for those that know what they are doing(the 1% remaining). grin
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:27pm On Dec 11, 2018
DMerciful:
UPS is a criminal organization, they will rob you with fraudulent duties by lumping packages together and then use estimated charges. I personally recommend FEDEX, they collect the import duty from the seller rather than the buyer!
Lol!
Thank you for the response
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:08pm On Dec 11, 2018
chris81964:
Charge controller and inverters. UPS engages in robbery. Avoid them at all cost. DHL is a legitimate business. If the value is too low no fees.
Thank you so much chris81964, that UPS issue was a real robbery! Thank God the client had experience such with them before.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:01pm On Dec 11, 2018
Evening Guys, I need urgent reply on this;
Fangpusun wants to give me a replacement CC(bluesolar), they requested to send it through DHL. The but there is that, I've had a nasty experience with UPS on epsolar sometimes back ( I had to pay extra 16k for a CC of around 40k, about 2yrs back. since then I only use china registered mail, I collect in post office no issues). So, is there anybody that has collected CC via DHL? Thank you.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:11am On Dec 07, 2018
Saipro:
Often true but ... I have on occasion seen one bad cell in a single battery promptly spawn bad cells in parallel batteries. Case in question had a bank of 4 batteries in parallel. Things were good for a long while so I went to sleep. I didn't notice until 2 of them had irrecoverably bad cells. I went on to separate into 2 banks of 12v x 2 in dual parallel config. I believe I made a post about it on this forum.

From that experience, it became pretty apparent that 12V batteries are cool but they're just 2V x 6 batteries hard-wired together in a single string The moment you run them in parallel, you experience the same issues as 2V x6/4v x 3/6V x 2 batteries in parallel without the benefit of isolating the bad cell without removing the entire battery. If you believe in God, you might need to pray your bank doesn't develop rogue cells.
The best config then is 2v(a cell) in series to form a battery. Thereafter continue with parallel and not exceeded 3strings.
Batteries and their wahala.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 12:00am On Dec 07, 2018
DMerciful:
Kilode! How can you say it's similar to this? Depending on the usage conditions and your ability to test, used batteries could be a good bargain.If you know the seller, the ultimate test is to run it for a day(24hrs)then pay
Lol grin
No mind me fa! I no dey near used batteries, except the ones used by me!
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 6:00pm On Dec 05, 2018
Buying used batteries is similar to you crossing an eight lane high way blind folded(99% chances of it not ending well).
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 1:52pm On Dec 04, 2018
anidat77:
Hello fellow DIYers....yesterday we lined up an alternate power line from my inverter to our sumo water pump I was told to be 1hp. At start up my 1.5kva inverter overload light came up and it shut down on the overload protection mode.
I know some guys here pump water effortlessly with their inverters so my question is which brand do you guys use.
Currently I use a 1.5kva Eco luminous inverter.
I'm skewed towards a prag or same luminous but with 24v battery bank source. But open to FTA advice.....not adverts grin
I ve pumped (1HP) with 2kva icellpower without any issues, it takes upto 46% of the inverter capacity without the overload light coming on (initial surge).
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 12:16pm On Dec 04, 2018
NiyiOmoIyunade:
Ngbam!

Oga Earthrealm sadly has more than two bad batteries although he doesn't want to believe it yet - any attempt to change batteries in bits is only going to worsen the situation.

Especially, Quanta cannot easily mix with KungLong - although both AGMs, their charge profiles (ideal absorb voltage) are very different - Quanta tops out at about 14.2v for absorb while Kunglong starts absorb from 14.4v. More especially, brand new batteries in pristine condition cannot mix with 8 month old batteries whose capacity has already been impaired.

It is either you start afresh or attempt to salvage 4 decent batteries from the entire bank of 8 while raising funds for eventual total replacement.
There is NO short cut to this, though it's painful right now, but its the best option he's got. @earthrealm, try and salvage 4 batteries out of the 8 and save up to get new ones(NEVER MIX THEM WITH NEW ONES). If you do, it will become more painful on the long run(new batteries will likely die in 6 months. It will require you to reduce your load for now.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 4:28pm On Nov 14, 2018
NiyiOmoIyunade:
Oga Roolnaado,

If I may, I believe your battery nominal voltage is set at 24v yes? And your 1.5kva inverter is also 24v?

If that be the case and you have 4 pcs of 24v nominal panels, there is no reason to be using a 2 x 2 config with a PWM CC - essentially you are wasting the power of 2 out of your 4 panels.

100w at 24v (30VmP) is about 3.3a per panel so seeing 6a combined as you reported is just about right with your current config.

PWM cannot use the excess voltage potential you have created by putting two 24v nominal panels in series - it is just wasted power. I believe Oga Saipro already advised you should put all 4 panels in parallel and this is what you need to do.

You should be able to see about 10 to 12amps total from your 4 panels in a 4 in parallel config under optimal conditions - this is what I believe you have to do next to progress this...
I don't want to belief the panels are 100w @ 24v, it should be 100w @ 12v with a current of ~ 5.7A. That should be the reason for 2*2 config. So at that, he should see around 11.4A (all things been equal, which can never be!). From the pics, I will multiply that figure(11.4) by an efficiency of 60%, ie 11.4*0.6=6.84A. So the current he is seeing is about right.

Note: Those batteries are going to die very fast! Kindly do the needful(buy a 'cheap' 15a 100v mppt Fangpsun CC and connect the 4 panels in series; with that wire gauge am seeing there).