Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 7:00pm On Nov 08, 2018 |
pranil: I think for 1000 Amp you need atleast 50 x 10 50mm(L)*10mm(B)? What about the thickness? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 2:39pm On Nov 08, 2018 |
mcTrinity: Good morning all,
please, shown is a picture of a Surge Protective Device rated 670VDC
will there really be any consequence if I use it in an AC circuit.? will it work?
thanks... cheers I want to belief this issue was discussed sometimes back. Please use AC for AC and DC for DC, no reason looking for trouble. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 2:07pm On Oct 05, 2018 |
@peaceland the panels are not connected to the controller. Kindly look for an electrician around to check the cables. Check the voltage at the terminal of d controller(panel voltage). Do this and we know what next. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 12:34pm On Oct 05, 2018 |
peaceland: Good morning house. Please I need help. Have a problem with my solar inverter system. Last Sunday came home in the night with the batteries fully discharged (red battery light on inverter) as I left a bulb on for 2 days security reasons. I suspect my batteries may be weak. Almost 2 years now. However since then its been a challenge getting the system charged via solar, charges with gen (phcn unfaithful this week). My questions are: 1. How can I know if the issue is with the solar panels or charge controller or batteries. 2. The inverter is supposed to prevent deep discharge, could it have failed?. Sorry a total novice in inverter terms but I noticed this morning on the epver charge controller the sign shows power leaving battery to bulb but no sign of power entering. Will snap and attach for clarity. Kindly help a novice brother. Thanks Additional: moon sign by the left of the charge controller meanwhile sun is up now! What time of the day was those pictures taken? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 5:39am On Sep 19, 2018 |
DUNKA: Please house I need your views/opinion on this issue below. If you wanted an Axpert 3kva inverter and a dealer had sent you pictures and agreed on the price and you sent the dealer the agreed funds awaiting delivery.
Dealer then confirmed that inverter had been sent. Fine no problem only at the point of collection the inverter you discover that the dealer sent you MustPower 3kva inverter without informing you.
Please how would you handle this? How would you feel?
I kindly need your candid thoughts on the above scenario. I really understand how u re feeling right now, like pranil said, if it is an honest mistake, no problem. Just return it and get the right thing u paid for. But if otherwise, on purpose, pls and pls, kindly let the house know who that person is(and he/she will bear the extra TP). Let me wait before I say more, am not happy at all, I know how our people can be. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 1:14pm On Sep 09, 2018 |
Malevonent: ha02 agm long 12 200ah batts 3batss are in sync,..1 batt is usually 0.08v higher when charging...and slightly less when discharging about 0.2v hvnt checked.wil chk and revert--though i dont think so i have it moving current, small amps, -ve leg of bad batt is usually about 0.8amps to 1.2amps, while +ve leg is 0.2amps, other 3 batts usually hv 0.4 to 0.9amps moving through them.
intend to loadt test each battery, as i recently acquired a 100amps load tester, and also the led voltage display is on the way too, so can post pics of the voltage readings..instead of the manual meter reading i do It's working then. Give it some time and u may need to move the particular battery to another position in the series( check wire connections etc). |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:34am On Sep 09, 2018 |
Malevonent: mine has been hooked up for over a month..1 batt still remains unbalanced. Kindly give more info: Name/model of balancer used. Type of batteries(flooded, gel, lifepo4 etc) Voltage readings on the individual battery How is the operation of the balancer, does it get warm while working? Do u have a clamp meter? Check if it's even moving any current between batteries @all. Balancer might be faulty. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 4:04am On Aug 12, 2018 |
Barezzi: Guys, Is there any danger connecting the AC output of an Inverter to its AC input? I actually tried it with a "1.5kva" inverter constructed by my student. It wanted to charge the batteries but couldn't and gave a sound as if it was overloaded. Note: it's just a basic law of physics, conservation of energy! You can't just create anything like that, no magic. |
Technology Market › Re: You Buy, I Ship and Deliver from Usa To Nigeria, Ebay @495/$ by Oshomo12(m): 6:12pm On Aug 11, 2018 |
temitimx19: Keep your orders coming  Item received. Thanks
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 9:50pm On Aug 04, 2018 |
blessedjohn: Hello house, pls is 150 watt solar panel enough to charge a 100ah battery. The battery level had refused to cross the 3bar level for the past 2 days. I'm using it with Roy solar charger controller 20amp. For a 100ah,12v; you will need a minimum of 250w panel(to take care of this kind period). |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 9:46pm On Aug 04, 2018 |
kiekie1:

We recently did a complete system overhaul after visiting a ROY solar site few days ago and felt the pains of the client.. The system was inefficient and installer wasn't really responsive to calls either ! Feel free to reach us for detailed enquiries,quality renewable energy supplies, installation & maintenance . Smartcell global services, 081-35031951 OMG! Are those batteries still good(how long have they been on that silly CC)? The installer should be sh.....t . That was too bad. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 3:02pm On Jul 22, 2018 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 11:58am On May 19, 2018 |
sinistrian: My concern is that a house load of 400W max is tripping a 63A breaker via the inverter. And this is a 48V system! If I put the 100A breaker in, it means I am giving a 2.4kva nverter the go-ahead to pull 4800 watts from the battery! Kindly check the inverter very well, it should never trip the breaker(25A) even at 50% load on, Talk less of no load at all! Maybe a short circuit or if there is a breaker in the inverter, it maybe faulty. Do check this and don't put a 100A breaker on a 2.4kva 48V inverter(except u want to use it to roast yam)! |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 4:28pm On Apr 27, 2018 |
abunafiu: Make una folllow me analyse this. Fridge, iron join others.
People need to wise up not to fall into wrong hands. This is what I talked about some pages back. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 3:34am On Apr 25, 2018 |
sinistrian: Updated stats: Even though today started hazy and there was initially poor output, the sun came out in full force by 8:30am max power = 2,354W out of 2,700W max current = 32.64A energy generated = 186AH Charge from 49.1% at 7am to 98.8% by 2pm, even with full house load on Wow, 87.2%, now u re talking! Very impressive, enjoy and enjoy. Zeestone, nice work there. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 3:47pm On Apr 23, 2018 |
sinistrian: The screenshot below shows that by 8:50am, I already get up to 700W of power, where the system would be struggling to produce 300W prior to the reorganization. Kindly do a new comparison, this one is not fair on the old system. Y? Cos u have added 900w extra! The old one had a 72.5% efficiency and new one is around 70.3%. So discharge ur batteries to about 50-55% DoD and let see the new stats. Lovely setup though, enjoy it. |
Romance › Re: She Doesn't Want To Apologize: Should I Forgive Her? by Oshomo12(m): 1:34pm On Apr 22, 2018 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:41pm On Apr 19, 2018 |
GeorgeD1: all, its been more than a year now since I started using my solar water heater. in the next couple of days I will be doing a review of the journey so far. a few surprises and a lot of flaks too. it has been anything but a dull experience. I look forward to ur review, both d beautiful and d ugly. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 7:00am On Apr 19, 2018*. Modified: 7:21am On Apr 19, 2018 |
davodyguy: Bug kudos to you, cos you started going Green and clean as far back as 8 years ago.
Some of us only started recently and we hope many more Nigerians embrace the clean energy.
I'm having issues with some of my neighbors now. Ask me why? They have a very terrible noisy generator. I've preached Inverter and solar, these fools claimed no money, but one of them recently bought a car worth 1.2million just to prove a point, cos they can't stand the fact that my wife uses SUV, hence the wife too needed to show off. That's how terrible mentalities of people are.
They run this gen whenever there's no mains power supply for almost 12hours in a 24 hours day, with the noise disturbing the neighborhood. In July, 2017 their 1kva Tiger generator caught fire, but luckily for us, it happened around 8:30pm. I used two of my cars' fire extinguishers to help them prevent disaster.
Thinking buying PMS to fuel gen daily is a sign of being rich is a stupid as a butterfly trying to fly as high as a bird.
I'm sorry I have to express myself to this extent, but that's how Nigerians are.
May God help us My brother, we have a lot of educated mumus in Nigeria, most of them with one degree or the other. Kindly explain to me why is solar expensive to them and they still on the average own at least 2 solid cars( some 3). I see them all around, some of my neighbors come to me that they heard "that they can power their freezers/use solar for as low as 150k" My reply is, you can even power ur all house free of charge! No need to even pay one naira. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 6:48am On Apr 19, 2018 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 2:02pm On Apr 17, 2018 |
nonoski: Thank you very much I have already done the string by string isolation and notice one of the strings is faulty (maybe due to wiring) so I put off the breaker so for now it's just 3S3P.
The thing is there has been Phed light since Friday till now so the batteries haven't really been drained so I can really tell the output of the CC. I want to believe one of the reasons for you to go solar is to reduce what u consumed from PHCN. So during the peak hours of sunshine, just put off ur PHCN supply and check what ur system will give u. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:32pm On Apr 08, 2018 |
pranil: 3. run two inverters ( one inverter charger large capacity for power-hungry loads with AVS 30 behind to cut really bad voltages
I run a 500 VA phoenix ( victron inverter on my 20 KWH bank fed by power ( to charge through neap and solar) the Pheonix power my computers and AV system essentially isolating them from NEPA , surges, bad voltages and allows me to tinker with main inverters while keeping essential stuff on I love this option, I also checked out the inverter, are u using the 12 or 24v version (l know that u have a 48v system). The output voltage is 120v, is that right or do u ve d 220v type? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 11:14pm On Apr 07, 2018 |
makavele: What you do?
Askorr .... Ibeere!! you know the rest Hope u didn't misinterpreted what I wrote? Oshomo12: Over sabi dey worry u(I can't blame u though; it's a DIY thread where anybody can answer ur question), he specifically mentioned Niyi, u see ur name and others there? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 11:09pm On Apr 07, 2018 |
Pranil mentioned the AVS30 but it seems to only work with a range of 'acceptable' voltages - it doesn't step up/down and will just cut off if dirty power comes in. Would a 5kva relay-stabilizer (non-servo because i'm cutting costs and also because I don't mind the +/- 10% variation in output voltage) be appropriate to put in between mains power and a 3kva inverter proper?[/quote]You need a stab after the mains, i.e. Ur inverter connects to a stab. Otherwise, garbage in, garbage out! |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 10:56pm On Apr 07, 2018 |
zeestone99: No involve niyi, jst block am 4 junction... Correct! By d way, did u grow up around Mushin(just asking)? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 10:52pm On Apr 07, 2018 |
makavele: Niyi; shey make I reply this guy; or make i free am ?  What I 'do'? Note: it's like u didn't get my point. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 5:44am On Apr 07, 2018 |
makavele: Less volts = more amps; and vice versa . .
since you increased voltage to 24V; battery would now be seeing half the amps under the same conditions
CC adjusts based on voltage Over sabi dey worry u(I can't blame u though; it's a DIY thread where anybody can answer ur question), he specifically mentioned Niyi, u see ur name and others there? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 11:06pm On Mar 18, 2018 |
Congrats @bigrovar enjoy ur self! My wife always tells me that ur setup is the smartest!  |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 9:53am On Mar 15, 2018 |
earthrealm: YEAH, THANKS @ALL, NIYI AND OSHOMO, i knew something was off, the calculation was just too good to be true, i forgot about discharge amps. the problems of excessive battery drain may be countered by running the sumo during times of good sunlight, so the solar panels might be bringinging in more than 70% of the consumption, with the battery making up the rest..and thus still follow the c20 rule? Yes, if ur solar can give u 45a at the time of pumping, the remaining 5a will be sourced from d batteries. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 6:27am On Mar 15, 2018 |
earthrealm: so just doing some mental maths, and its appearing too good, thus am asking some1 else to xchk.
2 x 12v x 200ah batt fully charged, hooked up to a 4kva 24v mustpower inverter, theoritical energy availabe is 4800wh, taking out losses etc, we have 4000wh, the user has a 1.5hp sumo pump and a single 5k liters tank wch takes 45 to 60mins to get filled, so from my calc. to run the sumo pump for 1hr will gulp roughly 1500wh?.....thus the batt would still hv a little juice above the 50% dod mark? With @Niyis' 745w, let me round it up to 1200w draw. This is about C4(50A) draw, using peukert number of 1.1( which is about the least). Ur 200ah capacity will drop to around 135.25ah!(this will be ur new battery capacity not 200ah). So pls re-do the math and see what u have. Note: u will still be above 50% dod, but that battery will die faster(~4times) than the one discharge with C20(which is d manufacturers' recommend). |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 7:11am On Mar 10, 2018 |
bodejohn: Thanks George, I don't want the price negotiations to derail the thread and since they are premium equipment, I don't want to also scare my customers... smiles. We know it's a premium cc and we are aware of the price. You still need to state the price. Do have nice day. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 6:27am On Mar 07, 2018 |
[quote author=makavele post=65625139][/quote]Vamp spotted! U no dey sleep ni? |