Rotecch77's Posts
Nairaland Forum › Rotecch77's Profile › Rotecch77's Posts
1 2 3 4 5 6 7 8 ... 226 227 228 229 230 231 232 233 234 (of 332 pages)
Thanks 08066619493 |
More
|
08066619493 |
It is possible by using double or single centrifugal pump combine with automatic pressure tank We can handle this for you. 08066619493 |
Ok, your case need special treatment. This is it water need gravity to flow. What you need is pressure pump. The question is * you need to consider that you will have 24hrs electricity *can all the occupant mentained the system. *consider that you will have standby pump incase of necessity. |
If i get you clearly you need adequate water is 1st and 2nd floor without tanks there, you wanted your tank to be at 3ft on ground floor. |
@good faith, this ur explanation is not clear enough *which type of structure did you erected. * what is the capacity of water tank did you need *you can post the pics of the structure so that we can get clearer pics of what you mean and possibly solution to it. |
More coming |
@baba Kenny thanks, That is a serious issue in some houses But there is a way we do it to get regular inflow of water but some bathroom appliance such as power shower needs more pressure to function very well but yet there is still a way to do it. Unless you need high pressure for your home which will require booster pump to do the magic. |
@adanny good pics there. But 0.5 hp is the lowest capacity in pumping machine and with that pressure tank on it it will serve a whole building perfectly ok. More so that pump you post there as sample is a very powerfully pump specially made it has 4 impeller which can full 2500 gallon of tank within 10min. Regular surface pump do have single impeller. But surbmersible pump do have about 12-30 impeller depends on the pump capacity That is why you see bore hole pump (surbmersible) do pump faster than surface pump. |
@egun, thanks for sharing this pics but there is a mistake there when posting the pics The pics there is VALVE,.. FLOATING VALVE OR BALL VALVE.used to regulate inflow and stopage of water into tank.(this can't stop pump) Your explanation is FLOATING SWITCH. This is very good to switch off the pump ones it reaches the level you set for it. I did same for a client that complain about pumping machine here sometimes ago. I will post the pics ones I see it |
Bring ur list and let's cost it for you |
Still on |
Yes oga kopell I beleived that was what oga fast shipping did. |
@oga kopell, thanks for this, although everybody has diff opinion about any issue.(accoding to how you said the issue has been discussed at some pages back) Pressure pump is been long available in nigeria , personally i know this pump as far back as 20yrs ago and before that I know some people would have known about it very well. Then water co-operation is still working and most mechanical work then is direct water system into the building no need of tank (indirect system) although some have tank as reservoir .. Then water leakage is not common bcs plumber use BSS GALVANISED PIPE HANDLE BY PROFESSIONAL PLUMBER. But fast forward to 10yrs now a lot of substandard pvc pipe couple with lazy non professional plumber handling the job make the pump become ghost. Without tanks just direct water system connection from water cooperation with adequate power supply or from your reservoir which will be connected to your pressure pump. Just open ur tap water will gush out with full pressure of about 5bar depends on how you regulate the pump ones you lock the tap the pump will stop. As I said up there bad material couple with bad workmanship made the pressure pump become problem to some building. Sometime ago at Ikeja gra a member called me for such issue. This is the short story, a company handle the job and finished it and deliver the job and the owner find it out that there is pressure pump but why low pressure again this people didn't answer (they have collected there balance) this now become a big problem for the owner, the house upper section of the building toilet stuffs ( power shower, jacuzzi etc) didn't function well . People are fuuny o they know what they did already there is pressure pump there as I said but you can't beleive they can't on it bcs the piping system there is bad I found out that they didn't consider this pressure system for the building from the beginning it after thought.(may be when the see that the height of the water tank is not enough and they can't add more to the height due to the pipe they us, that was my thought then) Later the owner of the building now test the pump what do you think that happen (1866 issue) leakages everywhere. Then i was called upon I change the whole piping system to better one up till now there are living fine there. I bet you if you have good plumbing work couple with light you are good to go with pressure pump without any issue. |
Oh one of the oga has posted one that I sold to him. Roger that. |
@ gbadex, thanks for your observation , it's still quick hydration which watering will eliminate if done at earlier stage |
@egun ,sir you are much correct o , even upon all pipe I mentioned I still do hydrolic test for all my work now either the owner planned for pressure pump or not I will still do it to be in safer side. 3rd pics pressure testing machine
|
I have diff type of pressure pump for sales, i have sold for many popular nairaland here There water low pressure issue is solved now. *The one with fixed small tank that has bladder inside. *Another one with automatic system (tankless) The pump has control which you can use to regulate the water pressure the capacity start from 0 bar -25 bar or more. But it's compulsory to use very thick pipe that can withstand the pressure bar and make sure professional handle the mech work if not .....what happened in 1877 will receive occur again. Recommended types of pipe *hence pipe and fittings. *Technogreen pipe amd fittings. I will post pics soon |
You can even use canvas, sand, water. But the cheapest one is water, so use water and do the curing within 3-7 days there is no crime if it's more than that more so weather condition of your area also contribute to the duration |
CURING is the spraying of water or spreading of sharp sand on surface of freshly made concrete to control it's moisture so to protect the concrete from quick hydration against cracking |
The depth is 1200mm Yes the pole are H. beam |
Still on |
New week new deal |
You can do single hole foundation (isolated) for the tank. What we did here is combined column foundation. Bcs *the soil bearing capacity is low. *also the coloums is near the property line . * also the columns is very close to each other The main. Aim is to get uniform load distribution under the whole area of the footing. Thanks for your time on our thread |
Quick hydration might likely be the cause that is why is good to do curing on any concrete |
More coming soon |
More coming
|
Still on |
More coming |
It will be available soon sir |
Solid Chrome executive kitchen faucet Price tag ,20k, 22k, 24k Italian bath mixer tap 15yrs warranty . 4th pics Price tag 25k
|
1 2 3 4 5 6 7 8 ... 226 227 228 229 230 231 232 233 234 (of 332 pages)