micbjrex:Let the man start with these quantity Cable size. Red. Black. Green 1.5mm. 3. 2. 3 2.5mm. 3. 3. 2 4mm. 2. 2. The 1.5mm green cable is going to serve as earth cable for the 2.5mm while the 2.5mm green cable is going to serve as earth cable for 4mm. But I don't how the your electrician fix the pipes. There are some switches that are 2-way switch and they are mostly used in all the rooms. If all the rooms are 2-way switch, you may likely buy additional 1.5mm green for traveller. The length of 16mm single core cable is dtermine by the distant between your cut-out/changeover switch and the distribution board installed. For the DSTV cable, the correct cable in the market is the one with 300yard which sells for 16000naira, there are other ones of 3,500/coil, 4,500/coil. They are good but not like 16,000naira. One coil of 3,500 or 4,500 cable should be okay for that except you want to run antenae cable together with the DSTV cable. |
micbjrex:Coleman cable is good and the quantity depend on the size of the building and the type things you are installing. But my fear is 4mm cable that he quoted 7200naira. The price of 4mm coleman is more than that. Let him confirm from recent market price. |
micbjrex:Coleman cable is good and the quantity depend on the size of the building and the type things you are installing. But my fear is 4mm cable that quoted 7200naira. The price of 4mm coleman is more than that. Let him confirm from recent market price. |
Nice weekend ahead |
ileman:Sir, one of my technician is in portharcourt presently and he can handle the job if we discuss. For your Electrical, plumbing design drawing and installation. Contact us For further info call 08033643191 or 08051750560 Whatsapp : 08033643191 Email; atope23@live.co.uk Pin: 24ED26C9 You can visit our thread: https://www.nairaland.com/1804476/complete-package-design-drawing-electrical https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9 Thanks Engr Tope |
Call us today...... |
Installation of changeover switch
|
Thanks for your call. We will give you our best service |
Nice weekend ahead |
mufutau55:Sir, we have Caterpillar(CAT), JMG, JCB(Marketted by Briscoeford and I believe the generator is from US) etc. Caterpillar is one of the most expensive generator in Nigeria |
mufutau55:You are welcome sir but if there is a way of adjusting the frequency to 50Hz it will work bcecause some of the electronics equipment importing to the country have 110V/220V AC input and it normally set to 220V which is our normal voltage in Nigeria. I have used such before when I was in school. It got burnt when a friend of mine mistakenly set it to 110V and plug it directly to 13A socket outlet without a step down transformer. Thanks sir |
mufutau55:Sir, in Nigeria our voltage is 240V AC supply with a frequency of 50Hz, bringing in 220V 60Hz generator may not work for the nigeria equipment and electronics because most of Electronics equipment in Nigeria is rated 240V 50Hz. Even with frequency of 51Hz, the sensitive equipment we have in Nigeria will have problem. The difference is the output frequency (1 Hz is 1 cycle per second, 50 Hz is 50 cycles for Nigeria, 60 Hz is 60 cycles per second and is most common in the US). Typically, most loads have a frequency range they are compatible with and it is very rare to see that range span from 50-60 Hz. |
Call us today |
Call us today |
or your Electrical, plumbing design drawing and installation. Contact us For further info call 08033643191 or 08051750560 Whatsapp : 08033643191 Email; atope23@live.co.uk Pin: 24ED26C9 You can visit our thread: https://www.nairaland.com/1804476/complete-package-design-drawing-electrical https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9 |
or your Electrical, plumbing design drawing and installation. Contact us For further info call 08033643191 or 08051750560 Whatsapp : 08033643191 Email; atope23@live.co.uk Pin: 24ED26C9 You can visit our thread: https://www.nairaland.com/1804476/complete-package-design-drawing-electrical https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9 |
or your Electrical, plumbing design drawing and installation. Contact us For further info call 08033643191 or 08051750560 Whatsapp : 08033643191 Email; atope23@live.co.uk Pin: 2BD4790C You can visit our thread: https://www.nairaland.com/1804476/complete-package-design-drawing-electrical https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9 |
Call us today |
mufutau55:Answered. Thanks sir |
Compliments of the season |
Happy new year to you all |
egin:Single Phase connection has 2wires which is live and neutral and 3phase connection has 4wires which is RED PHASE, YELLOW PHASE, BLUE PHASE and the Neutral wire. For the size of the building mentioned above I believe 3phase connection should be considered. Similarly consider single-phase as a single lane highway and three-phase as a multilane highway. There is a limit to the load that a single phase can handle and typically that number is set to 12 kW (or 12000watts. So if the total sum of wattage of all the appliances that you are running at a time is more than 12 kW, then you need a three-phase connection. And you can get over 12kW if you have 6numbers of 1.5HP ACs and water heaters all running together. If the load is less than 12kW, then a single-phase connection can easily handle it. Note: A lot of people have misconception that Air Conditioners require three-phase connection. Which actually is not true because all ACs have motors designed to run on single-phase. Only if you have more than 5AC's that are all in use together you may need a three-phase connection. |
egin:Presently in Lagos the 1 phase(single phase) is N39k+ but just get 45k for the total package because u will be ask to pay for other things(like form, stamp etc). I don't know how much is 3phase presently |
We want to use this medium to thank all our esteemed clients. Thank you for being part of success in the year 2014 and we look forward for better year. Thank you all. |
... ![]() |
Call us today |
Merry Christmas to all our esteemed clients |
Season greetings |
Distribution board
|
Season greetings
|
Happy weekend |
Conduit pipes and Fixing of cable basket for the supply cable into the building and termination into final subcircuit called distribution boards. ABB distribution board.
|
1 2 3 4 5 6 7 8 ... 177 178 179 180 181 182 183 184 185 (of 212 pages)