Re: Inverter Users : Lets Have Your Experience by spinola: 2:23pm On Aug 28, 2016
adrian5:
Hello all.

See there are some really competent guys in the house.
What's your experience with Blue gate 20A 2KVA 24V inverters?
I need to know:
Can a 3.5 KVA gen charge it?
Can I use 2 or4 12V200Ah or the inverter?(Maybe in parallel)
Is it a good brand of inverter?
Can a inverter Ac 1hp be connected to it?
What kind of charging time is required?

Thanks y'all

Hi,

Can a 3.5 KVA gen charge it? ANS: Yes
Can I use 2 or4 12V200Ah ?(Maybe in parallel) ANS: You can use two batteries connected in series to get the required 24 V or 4 batteries connected in both series and parallel maintaining the required 24 V
Is it a good brand of inverter? ANS: Bluegate is a big name in Nigeria, however i have not personally used their inverters.
Can a inverter Ac 1hp be connected to it? ANS: In theory yes. Is the inverter going to be used only for the AC ? I f not i would advise you buy a bigger Pure Sine wave inverter 5KV and above
What kind of charging time is required? ANS: Approximately 6 depending on depth of discharge and good NEPA light.
Re: Inverter Users : Lets Have Your Experience by spinola: 2:55pm On Aug 28, 2016
mercurydirect.com.ng Pay on Delivery

Mercury 1.2 KVA Ride Plus 12v 220 AH Tubular Inverter System ₦123,000 Only

Mercury 2.4kva Complete Inverter System (2x 200AH Mercury Elite Deep Cycle Batteries included) ₦256,000

Mercury Inverter 1.2 KVA (12V) Modified Sine Wave ₦41,000

Mercury Inverter 2.4 KVA (24V) Modified Sine Wave ₦44,000

Mercury Inverter 3 KVA (24V) Pure Sine Wave ₦170,000

Mercury Inverter 5 KVA (48V) Pure Sine Wave ₦210,000

Mercury Elite Deep Cycle battery 200AH ₦110,000 (₦90,000 when you trade your old batteries)

Re: Inverter Users : Lets Have Your Experience by adrian5(m): 5:15am On Aug 29, 2016
Thanks Spinola!
Re: Inverter Users : Lets Have Your Experience by CAROLYN19: 9:18am On Aug 29, 2016
Are you a retailer or an end-user and you need high quality, durable, efficient, BATERRIES, INVERTERS, UPS AND STABILIZERS ( with One year warranty) Contact us at Mary Victor Engineering Company. Phone No 08066332919.
Our range of products are:
• Gaston Batteries 12V:5ah to 2V:1500ah (200AH IS OUT OF STOCK)
• Xantrex Inverter, Outback Inverters and Artronics Inverters
• Stavol and Tengen Stabilizers 2KVA to 300KVA
• Emerson(Liebert), Leums and Artronics UPS 650VA to 100KVA.
Re: Inverter Users : Lets Have Your Experience by zeestone99(m): 9:08am On Aug 30, 2016
Call us for your solar and inverter installations, 08117398294 or email Info@monzpowersolutions.com

Re: Inverter Users : Lets Have Your Experience by Nobody: 10:12am On Aug 30, 2016
zeestone99:


They don't weigh d same, it should be labeled I.e if you buy from a reputable company, otherwise you will have to use it and use the backup time you get to knw if it's 200 or 150ah

thanks bro....but labelling can be manipulated. There is actually an equipment to do that. I checked online. Would probably need to order one.

1 Like

Re: Inverter Users : Lets Have Your Experience by zeestone99(m): 10:57am On Aug 30, 2016
bjims:


thanks bro....but labelling can be manipulated. There is actually an equipment to do that. I checked online. Would probably need to order one.

That is why I said if you buy from a reputable company, I sell original batteries luminous, genus, mpower, ritar and quanta, call me on 08117398294 to order or mail me on Info@monzpowersolutions.com
Re: Inverter Users : Lets Have Your Experience by femarse: 11:48am On Aug 30, 2016
tholuxanny:
Still thinking if inverter/solar solution works? You need to ask those who have good solar/inverter solution in their homes or offices and change your idea or misconception about it. Our inverters have LED display that shows the wattage consumption, voltage output and the battery level. You can also set the charging priority to either solar or utility. We have 1.4kva, 2.4kva, 3kva in stock. For enquiry and order please call 07032687954
please what's the inverter set up for the following and cost Implication
32 inch TV
gotv
home theater
one energy saving bulb
one laptop and roughly 3 or 4 phones
Re: Inverter Users : Lets Have Your Experience by Nobody: 12:25pm On Aug 30, 2016
zeestone99:


That is why I said if you buy from a reputable company, I sell original batteries luminous, genus, mpower, ritar and quanta, call me on 08117398294 to order or mail me on Info@monzpowersolutions.com

no wahala bro as long as u stay in abj. looking forward to doing biz with u
Re: Inverter Users : Lets Have Your Experience by zeestone99(m): 11:43pm On Aug 30, 2016
bjims:


no wahala bro as long as u stay in abj. looking forward to doing biz with u
I'm based in lag, but deliver nationwide, holla me wen ready
Re: Inverter Users : Lets Have Your Experience by zeestone99(m): 11:47pm On Aug 30, 2016
femarse:

please what's the inverter set up for the following and cost Implication
32 inch TV
gotv
home theater
one energy saving bulb
one laptop and roughly 3 or 4 phones


2kva inverter setup, 280k. Setup includes 2ba3s, ba3 rack, delivery n installation. inverter can power ur fridge n smal washing machine
Re: Inverter Users : Lets Have Your Experience by Experience4u(m): 1:11am On Aug 31, 2016
Good morning gurus in the house, I just acquired a 1kva(1000V) African master power inverter and a one 200ah/20hr synergy intelligent battery. Pls what and what should I use on it as to get better juice out of it. And what are the precautions to take not to damage the unit. Thanks
Re: Inverter Users : Lets Have Your Experience by inikamoze(m): 3:13am On Sep 02, 2016
Hello experts in the house, I have a little problem..I need HELP PLS!!!

I traveled for 6 weeks and when I came back I tried putting on My Mercury Radiant 1000 inverter but wont turn on and the red light comes on when switched on with Nepa power, what could be the problem?
I always disconnect all my appliances whenever I would leave my home for a long time and the batteries were working fine,to be sure it was not the battery(2nos 155mAh) I left the inverter connected to Nepa light and the inverter charged the batteries to full. The inverter comes on with a humming sound when NEPA light is available, but will not turn on when used with the batteries, it will make the humming sound as if it wants to start and stops just after 5 seconds. The RED & Green lights stay on when switched on and that should be a sign of a fault in the inverter...I think
How can I fix this pls?
Attached is an image of the model
Re: Inverter Users : Lets Have Your Experience by tholuxanny: 7:40am On Sep 02, 2016
1.4kva inverter and one 200ah battery can power your request.
160k will do.

femarse:

please what's the inverter set up for the following and cost Implication
32 inch TV
gotv
home theater
one energy saving bulb
one laptop and roughly 3 or 4 phones

5 Likes

Re: Inverter Users : Lets Have Your Experience by earthrealm(m): 10:04am On Sep 02, 2016
femarse:

please what's the inverter set up for the following and cost Implication
32 inch TV
gotv
home theater
one energy saving bulb
one laptop and roughly 3 or 4 phones


if u have money , go for 2 x 200ah batts or 2 x 150ah battery,
using a single battery will put much strain on the batt, it will pack up b4 18months, and u may need to buy another batt

imagine driving to lagos from abuja on a 2cylinder , 4 cylinder and 8 cylinder car, while each car can make the trip, over time, the 2 cylinder car will likely breakdown first, while the 8 cylinder will serve u many many yrs...same goes for batt n inverter system,s

1 Like

Re: Inverter Users : Lets Have Your Experience by admindim: 3:27am On Sep 03, 2016
earthrealm:


if u have money , go for 2 x 200ah batts or 2 x 150ah battery,
using a single battery will put much strain on the batt, it will pack up b4 18months, and u may need to buy another batt

imagine driving to lagos from abuja on a 2cylinder , 4 cylinder and 8 cylinder car, while each car can make the trip, over time, the 2 cylinder car will likely breakdown first, while the 8 cylinder will serve u many many yrs...same goes for batt n inverter system,s
IS NOT TRUE BATTERY HAVE CYCLES SOME COMES WITH 1000CYCLES THESE KIND OF BATTERY DOES NOT LAST FOR MORE THAN 1YEAR AND MONTHS ETC GASTON,POWERWAVE,SYNERGY,SUCAM.MULTIPOWER BATTERY WITH 2500/3,500CYCLE QANTA,INDEX,LUMINOUS, LAST FOR MORE THAN 3YEARS AND MONTHS BEFORE HAVEING ISSUES AND INVERTERS MATTERS TOO SOME INVERTER DEEPLY DISCHARGES BATTERY WHY SOME OVER SO ALL THESE FACTORS MAKE BATTERY NT TO LAST LONG AND SOME PEOPLE BUY REFURBISHED BRAND NEW BATTERY SO AFTER LIKE 6MONTH BATTERY WILL START HAVEING PROBLEM

3 Likes

Re: Inverter Users : Lets Have Your Experience by chris81964(m): 4:31am On Sep 03, 2016
earthrealm:


if u have money , go for 2 x 200ah batts or 2 x 150ah battery,
using a single battery will put much strain on the batt, it will pack up b4 18months, and u may need to buy another batt

imagine driving to lagos from abuja on a 2cylinder , 4 cylinder and 8 cylinder car, while each car can make the trip, over time, the 2 cylinder car will likely breakdown first, while the 8 cylinder will serve u many many yrs...same goes for batt n inverter system,s
The number of batteries should not be what you look at first. Your ah usage or Watt hours should be the first consideration. The second is the depth of discharge. These two factors determine the battery bank size and how many batteries.
Your analogy using an 8 cylinder car is flawed. Modern cars come with cylinder deactivatation. If the car's computers determine that running on two cylinders is more efficient it would do so with no commensurate wear on the components.
One battery will work as fine as two batteries if he meets thee criteria. How is one battery different from 2.? If the design calls for 200 AH a single battery or two 100 ah batteries give the same results and the same cycle use.

3 Likes

Re: Inverter Users : Lets Have Your Experience by darocha1: 8:20am On Sep 03, 2016
chris81964:

The number of batteries should not be what you look at first. Your ah usage or Watt hours should be the first consideration. The second is the depth of discharge. These two factors determine the battery bank size and how many batteries.
Your analogy using an 8 cylinder car is flawed. Modern cars come with cylinder deactivatation. If the car's computers determine that running on two cylinders is more efficient it would do so with no commensurate wear on the components.
One battery will work as fine as two batteries if he meets thee criteria. How is one battery different from 2.? If the design calls for 200 AH a single battery or two 100 ah batteries give the same results and the same cycle use.


You have said it all

Re: Inverter Users : Lets Have Your Experience by earthrealm(m): 2:22pm On Sep 03, 2016
lol, dont understand why we are all arguing.
dude said he has 1 32 inch tv..lemme assume its lcd = 150w
1 home theater = 80w
1 laptop = 60w
1 bulb = 20w
gotv/phone charger etc = 20w
total 370w
total energy is 12v 200ah batt = 2400wh @ 50% dod = 1200wh, factorin in efficnecy factor and losses = 1000wh

so his 370w load will last roughly 1000w/370 = 3hrs!!!

am really pissed that u guys are arguing over shit like this, so if this guy is ur client u will advice him to go for 1 battery??

advice like this has put many people off the solar/inverter or RE thing, as where u want to save money for him by suggesting a lean setup, it ends up back firing as the system fails to deliver, as client goes away believing that inverter doesnt work.

i have friends who people like you hv adviced wrongly and they ended up regretting and having to upgrade thier system at a very high cost within 2yrs. if u are well grounded in something, a simple glance tells u what may b wrong, i dont hv to bother abt dod/wh, usage time etc...for such an elementary scenario the OP posted. my motto is KISS = keep it simple s,tupid

admindim:
IS NOT TRUE BATTERY HAVE CYCLES SOME COMES WITH 1000CYCLES THESE KIND OF BATTERY DOES NOT LAST FOR MORE THAN 1YEAR AND MONTHS ETC GASTON,POWERWAVE,SYNERGY,SUCAM.MULTIPOWER BATTERY WITH 2500/3,500CYCLE QANTA,INDEX,LUMINOUS, LAST FOR MORE THAN 3YEARS AND MONTHS BEFORE HAVEING ISSUES AND INVERTERS MATTERS TOO SOME INVERTER DEEPLY DISCHARGES BATTERY WHY SOME OVER SO ALL THESE FACTORS MAKE BATTERY NT TO LAST LONG AND SOME PEOPLE BUY REFURBISHED BRAND NEW BATTERY SO AFTER LIKE 6MONTH BATTERY WILL START HAVEING PROBLEM


chris81964:

The number of batteries should not be what you look at first. Your ah usage or Watt hours should be the first consideration. The second is the depth of discharge. These two factors determine the battery bank size and how many batteries.
Your analogy using an 8 cylinder car is flawed. Modern cars come with cylinder deactivatation. If the car's computers determine that running on two cylinders is more efficient it would do so with no commensurate wear on the components.
One battery will work as fine as two batteries if he meets thee criteria. How is one battery different from 2.? If the design calls for 200 AH a single battery or two 100 ah batteries give the same results and the same cycle use.

4 Likes

Re: Inverter Users : Lets Have Your Experience by chris81964(m): 3:36pm On Sep 03, 2016
earthrealm:
lol, dont understand why we are all arguing.
dude said he has 1 32 inch tv..lemme assume its lcd = 150w
1 home theater = 80w
1 laptop = 60w
1 bulb = 20w
gotv/phone charger etc = 20w
total 370w
total energy is 12v 200ah batt = 2400wh @ 50% dod = 1200wh, factorin in efficnecy factor and losses = 1000wh

so his 370w load will last roughly 1000w/370 = 3hrs!!!

am really pissed that u guys are arguing over shit like this, so if this guy is ur client u will advice him to go for 1 battery??

advice like this has put many people off the solar/inverter or RE thing, as where u want to save money for him by suggesting a lean setup, it ends up back firing as the system fails to deliver, as client goes away believing that inverter doesnt work.

i have friends who people like you hv adviced wrongly and they ended up regretting and having to upgrade thier system at a very high cost within 2yrs. if u are well grounded in something, a simple glance tells u what may b wrong, i dont hv to bother abt dod/wh, usage time etc...for such an elementary scenario the OP posted. my motto is KISS = keep it simple s,tupid




Read what I wrote again before you comment. If you did not understand what I wrote ask for clarification.
Re: Inverter Users : Lets Have Your Experience by inikamoze(m): 6:49pm On Sep 03, 2016
Please where can I get my Mercury Radiant 1000 inverter fixed, it does not come on when switched on, and when current passes through it, the red light beeps continuously, manual says overload or fault..I think its a fault.
Please inverters in the house, who can help fix it?

Re: Inverter Users : Lets Have Your Experience by peaceland(m): 8:54pm On Sep 03, 2016
Good day al,
Please I need some clarification and advice.
By my own calculations need 3.5kva to run all home appliances
However based on cost of setup looking at a 1kwh system to power small-mid sized freezer, a TV and lights. Cfl& leds up to 10
I intend to power only the freezer during 9am-3pm and tv+ lights during 8pm-10pm.
Generator will be on between 6-8pm for water pumping.
I am presently 100% off grid.
My situation is that even though the promotional materials I read seems to suggest 1kwh is good for a 3 bedroom 24 hours I am kind of worried may not satisfy me and i don't want to end worse off.
I have also not been able to understand or convert kva to kwh.
So will appreciate advice on if 1kwh system can work as I planned or not.
Thanks a lot.
Re: Inverter Users : Lets Have Your Experience by zeestone99(m): 8:30am On Sep 04, 2016
peaceland:
Good day al,
Please I need some clarification and advice.
By my own calculations need 3.5kva to run all home appliances
However based on cost of setup looking at a 1kwh system to power small-mid sized freezer, a TV and lights. Cfl& leds up to 10
I intend to power only the freezer during 9am-3pm and tv+ lights during 8pm-10pm.
Generator will be on between 6-8pm for water pumping.
I am presently 100% off grid.
My situation is that even though the promotional materials I read seems to suggest 1kwh is good for a 3 bedroom 24 hours I am kind of worried may not satisfy me and i don't want to end worse off.
I have also not been able to understand or convert kva to kwh.
So will appreciate advice on if 1kwh system can work as I planned or not.
Thanks a lot.

You can't just sey, 1kwh ll b enuf 4 a 3 bedroom flat, ur appliances and hw long u want dem running determines that. We can get you an affordable setup provided you giv us all details, I.e ur appliance, dier wattage, n hw long in hrs u intend to use dem per day. Send us a mail if interested. Info@monzpowersolutions.com
Re: Inverter Users : Lets Have Your Experience by zeestone99(m): 8:31am On Sep 04, 2016
inikamoze:
Please where can I get my Mercury Radiant 1000 inverter fixed, it does not come on when switched on, and when current passes through it, the red light beeps continuously, manual says overload or fault..I think its a fault.
Please inverters in the house, who can help fix it?

Re u in lagos
Re: Inverter Users : Lets Have Your Experience by zeestone99(m): 8:36am On Sep 04, 2016
Earthrealm y u dey para
Re: Inverter Users : Lets Have Your Experience by truthfulness(m): 9:33am On Sep 04, 2016
femarse:

please what's the inverter set up for the following and cost Implication
32 inch TV
gotv
home theater
one energy saving bulb
one laptop and roughly 3 or 4 phones

I will advise you go for Luminous Eco Volt 1050VA/12V goes for abt 45-48k. and get 1-2 battery depending on ur choice. I just got mine n d inverter is good. carried 3laptops, 32inches flat screen, ps3, dstv, 6energy saving bulb without showing overload.

3 Likes

Re: Inverter Users : Lets Have Your Experience by truthfulness(m): 9:38am On Sep 04, 2016
bjims:


no wahala bro as long as u stay in abj. looking forward to doing biz with u
I have a 12V 190AH battery for sale in Abj. working very well and reason I am selling it is I v a 1050VA inverter n 4batteries so I m selling d extra 2.

Re: Inverter Users : Lets Have Your Experience by chris81964(m): 11:42am On Sep 04, 2016
peaceland:
Good day al,
Please I need some clarification and advice.
By my own calculations need 3.5kva to run all home appliances
However based on cost of setup looking at a 1kwh system to power small-mid sized freezer, a TV and lights. Cfl& leds up to 10
I intend to power only the freezer during 9am-3pm and tv+ lights during 8pm-10pm.
Generator will be on between 6-8pm for water pumping.
I am presently 100% off grid.
My situation is that even though the promotional materials I read seems to suggest 1kwh is good for a 3 bedroom 24 hours I am kind of worried may not satisfy me and i don't want to end worse off.
I have also not been able to understand or convert kva to kwh.
So will appreciate advice on if 1kwh system can work as I planned or not.
Thanks a lot.

1 Kva is 0.8kw. Take your loads multiply by the number of hours you want to run them for. Divide the result by 4 and you will have how much in watts you need in panels.
Lcd TV 8 hours. 8 x 100 w = 800 Watt hours. Divide by 4 = 200. You need 200 watts in panels to power your 100 Watt TV for 8 hours.
I hope this helps.
***4 is sun hours*****

3 Likes

Re: Inverter Users : Lets Have Your Experience by Rotiix(m): 12:33pm On Sep 04, 2016
truthfulness:

I have a 12V 190AH battery for sale in Abj. working very well and reason I am selling it is I v a 1050VA inverter n 4batteries so I m selling d extra 2.
How much
Re: Inverter Users : Lets Have Your Experience by truthfulness(m): 1:26pm On Sep 04, 2016
Rotiix:
How much
60k. Original Monbat battery. You can check it out.
Re: Inverter Users : Lets Have Your Experience by femarse: 5:35pm On Sep 04, 2016
truthfulness:

I will advise you go for Luminous Eco Volt 1050VA/12V goes for abt 45-48k. and get 1-2 battery depending on ur choice. I just got mine n d inverter is good. carried 3laptops, 32inches flat screen, ps3, dstv, 6energy saving bulb without showing overload.

the price fit exactly my budget and the things it supported fitted mine as well pls can u give me a snap shot of it including your battery and the inverter

thanks

2 Likes

(1) (2) (3) ... (48) (49) (50) (51) (52) (53) (54) ... (166) (Reply)

How To Hack Any Wifi Network Password Using Cmd / Huawei USB Modem Unlocker - Download Here! / Post Your Computer (PC) Troubles Here.

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health