Drgreatone: Thanks everyone for the contribution. Want to set up a low cost 12vsetup for my mum thats why I asked abt difference in pwm/mppt charge. The pwm seems cheaper and within budget but want to be sure if 4 150w panel or 2 300w panel wud give same results with it. Would also need recommendations for an efficient pwm charger too? Thanks
If upgrade is not in the plan, Stick to PWM it's more efficient with 4, 150w panels.
Drgreatone: Pls bell my curiosity. For 2 colleagues installations, curious as to which would be more efficient. A 2kva12v hybrid inverter connected to a 12v200ah lithium battery and a 4.2kva24v hybrid inverter connected to a 24v100ah lithium battery. Both using 2 415watt jasolar panels. Would there be any difference also in the charging time and discharge rate assuming same loads? Thanks
There is no difference in the Storage capacity.. What will matter in the discharge depends on efficiency of the Inverter used.
The 4.2kva 24 maybe more efficient and vice versa.
abbeymighty: Hello house, please i need advice, i have 4pcs of 300w panels, with 3kva hybrid inverter and 40ah mppt CC, i decided to to connect two panels to inverter and two panel to CC, on the same 24v bat3. Will it work, the inverter max over watt us 600w and 75v voc while CC is 1400watt and 150v voc Please advice
This is my current setup Jinko 560w x8 Sunshine solar 430w x6 Sunshine solar 450w x6
3 CCs, one for each 1 inverter 7.5kv Felicity transformer base
2 Wakatek lithium batteries 12.5kwh (LB48250)
Everything is connected to 2 busbars (+&-)
Question: I want to add at least one more battery but currently the distributor is out of stock. What will be the effect if I add another brand of lithium battery possibly of different capacity? If that is even possible
Lithium is Flexible, go ahead.. only requirement is it must be 48V battery, capacity, age, brand does not matter
clevermugu: Telling someone to shut up in a conversation is not ideal.. according to the pictures, did u actually sold him a pack coupled with those old overused and mismatched cells?
did u couple a small LFP pack (mtn lumos) with a 3.7V li-ion bms?
Just to clear something here, there are some BMS, example JK bMS, you can either use it Lion or LFP. user can select type of battery. and configure accordingly.
only issue is if you used Lion Settings on LFP batteries.
kristien4: batteries are 2 weeks old... is it possible that exact battery was actually low wen it was connected in series, hence did not attain the level of charge the others had?
For a new battery then, you need to equalize them, charge all in parallel, with a 12V charger until it's Full Full.
brightk: Anyone with experience using poly panels for installations.. what are the cons and pros of using dem as regard to mono... I heard de are less efficient than their mono counterparts
Efficiency is in the Space not in power, the Technology has come far that they are on par.
princely009: Hello house. Pls one quick question that i need a possible solution for. My 2HP 1.5kw rated submersible pump draws about 2.4kw when being used. Later found out that it was installed with a 1.5mm cable. Even tho my system (5kw inverter, 3kw solar array and 12kwh LiFePO battery) can power it on sunny days, i am more concern on the battery on cloudy days. Hence my question...
1. Do i get more solar panels to cope with the current draw esp on cloudy days? OR 2. Reinstall the pump with a bigger cable like 2.5mm or 4mm cable to reduce current draw.
Increase cable, energy saving is better than energy generation
obitobe: Will it be possible for me to adjust the charging current and low cut off voltage on a hybrid inverter?. with my inverter i cannot adjust anything. what that is even more annoying is that with main the charging current is 15.2A max and the low cut off voltage is 21.6v for the battery.
Yes, most definitely, you can set cut off and charging current. You can charge from as low as 2A, depending on your model, or as high as 60A/80A from AC charger.
obitobe: My setup, -2.7kwp of panel -solar Charge controller 60A (external) -2.5KVA transformer inverter (Afripower) - 4 flood lead acid batteries( 12v, 220AH)
Hybrid are more efficient if you are using Grid and Solar to charge. It save your electricity bills if you are metered. It will do the same job as a separate Controller.
Recommended charging current is like 20A for these set up. Which I believe your 2.7kwp is capable of.
Considering you have flooded battery.. only way to increase speed is increase the charging current.. you may have to top the water from time to time.
obitobe: I need to ask, I plan on upgrading my inverter from a non-hybrid 2.5KVA to either a 3.0 or 3.6KVA hybrid inverter, but my questions are apart from taking additional loads,
1. does a hybrid inverter help to speed charging time for a flood lead acid battery for this range of capacity.
2. for those using hybrid inverter with flood lead acid battery, what is your experience like.
Please I need your expertise here.
I will be waiting for feedbacks.
What's your definition of Non hybrid and Hybrid... ?
What's your current setup, how do you charge..
My own definition of Hybrid is that it has. Solar Charge Controller inbuilt. In addition to the AC charger.. In essence the charging Algorithm is the same.
1. about Speed charging.. this depends on many factors. What determines the speed is the current you are charging with.
Namzy: I remember seeing a YouTube video where someone made a custom iPhone charger with 100 chargers connected to one port then to the iPhone and it charged normally.
This comparison is not it he didn't show the total current output. all those apple devices acted as one because it's based on Apple's tech. He should use a 5V 150A power supply.. even Apple devices detects a non MFI compatible devices..
bassdow: I'm sorry, not here for this. I'm mostly on Nairaland when I need clear ma head. My comment was a general one which applies to all things circuits.
AND that's why batteries HAVE current limiter ELSE the BATTERY would TRY to DRAW all THE current it needs in a single go
Take a laptop's charger for example - when the charger in use has current rating lower than recommended, the charger gets warm / hot during use. That's because that charger is struggling to supply the quantity of current the connected device (Laptop) is drawing. Now if the difference between recommended current vs what the charger can provide is wide, the charger, NOT the LAPTOP would SPOIL.
Now when the Charger has a volatge much much lower thn whats recommened, the laptop won't power at all.
BUT if that same charger has voltage higher than what's recommeded, and the endurance ratio is exceeded, that laptop's circuitry would fry.
Again Voltage FLOWs IN CURRENT is DRAWN
Where are you reading all these?
Stop using Appliances Analogy for Batteries and Chargers..
I thought you agreed to that in your previous comment!
bassdow: Current is NEVER TOO MUCH because the applicance draws what it needs. It's Voltage that CAN BE TOO MUCH because it flows into the connected device.
in other words, if a phone's charger is rated 5-volts 2A , you would have no issue connecting it to a charger rated 5-volts 400A. BUT no make mistake connect am to charger of much higher Voltage.
All information is wrong..
Battery that does not have BMS cannot limit the charge current..
Also don't attempt to connect a 5V, 400A, 2000 Watts into phone. You will smoke the cable as well as the phone as there is a power limit the board can handle.
kristien4: its written @c20 rating. Then recommended maximum charging is 10% of battery capacity. I was thinking since its four battery connected in series 40amps should be okay... but i noticed a low bubbling sound while charging the 4 batteries(tubular)at 40amps current. Is it normal?
ojesymsym: I read that the iPhone 15 has a feature that limits battery to just 80% to prolong the life of the battery. I thought this was bad practice years ago, has this changed? If so, can we adapt it to renewable energy?
It's possible when dealing with Lithium or similar that has customizable BMS.. not with Lead Acid or tubular