osayuwamwen: This is the Felicity charge controller I bought for 105k, is this one good also, pls u guys should also help me with the name of a good 12v 1.5kva or 1.7kva inverter I should buy and a good flooded tabular battery
Get Felicity as well, the version below with low idle consumption
Valto: 400w ke! odi egwu according to the sticker specs na low quality 300w panel be that! max power voltage 36v max power current 11.11A (over stated) open circuit voltage 44.28v
close eye buy original jinko or yingli panels. don't waste money on that crap!
Boss your assumption may be misleading. He has a 400w panel.
Panel Rating = Vmp X Imp 36 x 11.11A
That it is overstated is another topic, untill tested you cannot assume.
Trippledots: If the panels active face was facing sunlight, then I think that was too long to be shorted out. A shorted panel will be pulling max amps over the period of time, and that power will be dissipated somehow mostly as heat which will be quickly reducing the life of the module.
The End cable melted and short due to fire incident. It was like that for that like as the person didn't separate the end cable.
zeestone99: Is this a good idea. Won't you be causing any damage by engaging shortcircuit.
If the practice works then fine, I was at colleagues place where his PV cable was short circuit for more than 2 weeks. I separated the cable and tested the PV and they work.
adrusa: For the felicity crew in the house, I need some help and information.
I bought a new 120A Felicity Charge Controller yesterday, but it appears to be working differently from the previous one I have. I expect the Charge Controller to come up when I connect it to battery, but it does not. It only came up after I connected the panel. However, once it is dark, the controller died again. It woke up again this money once the sun came up.
The previous one wakes up even in the middle of the night when I press the on/menu button.
Can anyone with recent Felicity Charge Controller please share their experience with me.
Fapemz: I have the right power solution for your starlink that will not overload your current setup. These set of Lithium Iron Phosphate battery is the best bet for your money. 08065.31.6307 is the number to get thru to us....whatsapp preferably
I have Solar setup already. I finally tested out the consumption on Startlink. Ranges from 35w to 45w
dollarnaira: Dc voltmeter led display 2k? . Una too funny .
Boss Naira is almost 1k to a dollar already. DC voltage Meter on AliExpress is about 2 USD already how much do you want to buy it locally? Until we are able to produce in this country Na so small things go cost.
Whytehandy: Good afternoon house, please I need a recommendation for a good 5KVA 24V smart hybrid inverter with low self-consumption (preferably wallmount type) with lithium charging capacity that I can use for my 1.5Hp inverter AC, fridge, freezer and other basic load like TV, fan and light.
A friend has already helped me to build a 230ah24V lithium battery bank and am also planning to buy at least 2400W solar panels.
I beg help me with the right choice of inverter as I am confused on what to go for. Thanks and God bless.
ask4bk: Make sure you put off the snow melting option completely coz that eats power. It consumes when you starting it and it's searching for network, but after it has found and it's idle, it should be consuming around 40w
I turned off immediately after installation.. As per my previous post, Power consumption is 50 w to 75w average as per specification which is in line with my experience. Mine never consumed 100w.
ask4bk: Bro, mine eats 100w. Is that what you calling power hungry? That's like a ceiling fan. Anyway, for me I've enough batteries so I don't feel the 100w. Maybe your backup is small that's why u feel it
Most of my appliance are energy saving, Imagine Starlink competing power with my Freezer of 120w, it consume more than my refrigerator, TV etc.
Yes power hungry for a router and Dish.. in comparison to traditional DSTV dish or Routers that only consume less than 20w
I have enough backup just noticed an increase and was wondering why
Starlink is power hungry I was not expecting this consumption so I never bothered researching it was when I got I realised increase on my inverter consumption, had to check specs to see it's consumption rating 50w to 75w average.
Starlink is for those who have solved power problem and already using other ISPs.
I use Swift WwTx 10Mbps, paying 28k monthly, was frustrated recently, their service will go off for hours.
Starlink is just 4k addition monthly and outages is less than 1 minutes if any. Speed is close to 300Mbps on 5GHz.
zeestone99: You will inhale gas from your tubular batteries if it's inside your house. Cross ventilation will not save you. Who still opens windows and curtains in their houses wide open like they are in the village.
No mind them boss, even Some of the Sealed lead acid dey release gas.
zeestone99: If your mains had come on when your inverter is sensing no battery. Chances are high it could blow up the FETs.
Nope as I switched on the Grid, It switched to NO battery mode as it works without battery.
It was PV (High VOC)that was trying to wake the BMS, but it went to fault after 2 tries and says no battery.
And worked without battery.
Also when the inverter send current to charge, it start’s gradually from 0.1A and cranks up so there is no fear of blowing up, it does not push high current to charge.
olopan: If this scenario was to be the case, and your BMS was properly configured to prolong your cell life with recommended settings then only the discharge part of the BMS will go off, while the charge part stays on.
when you need it to charge, it will receive the charges fine.
Just to add based on Daly BMS i use, if LVD is reached you will have to disconnect load for few seconds for BMS to restart, last time this happened my inverter went into fault mode as it tries to wake BMS but Discharge FET is off so its seeing No battery.
Incase of HVD, there is no issue. Inverter stops charging but still have Battery connected as it still see battery with Discharge FET turned on. See attached
oloet: Does this mean that I cannot use (3) 300w panel with VOC of 44.5v on a 12v system with a mptt controller with max panel input of 160v?
Combine your 44.5v panels until you reach close to 160v of controller
3 x 44.5v is 133.5v, you are good to go! For MPPT you just have to consider the VOC of the controller to determine how many panels to reach max 90 to 95% of the CC VOC