Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 9:10pm On Jan 26, 2023
isangjohnson:
What roles do the pv voltages really play when designing a system?
I personally do not always pay attention to them. I only focus on other parameters such as Voc and co, watt, company name including purchasing source, etc.
Not all specs is important as long as you find what you are looking for.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 6:07pm On Jan 26, 2023
isangjohnson:
All these 12v, 24v, 48v......pv, how una dey tek identify them?
Basically it depends on number of cells, however you may also use Vmp of the panel to determine the panel voltage.

17V to 19V Vmp is 12V
34V to 38V vmp is 24V
These are most common panels
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 10:50am On Jan 25, 2023
zeestone99:
For those having issues of grid consuming their units during charging. Many low frequency inverters (transformerless inverters) are dumb. That's why people go hybrid, sadly not everyone likes hybrids.
We now have smart transformerless inverters for you. You no longer have to worry about your inverter charging your batteries anytime there is grid supply. You can simply disable charging or set bypass mode. The inverter
bypasses( supplies ) you mains without charging your batteries. Win win for all

No need to break the bank.
Check our affordable prices and dm to order while stock last.

Snadi 3.5kva 24v - 275k
Snadi 5kva 24v - 345k
Snadi 5kva 48v - 345k

Call/chat - 08117398294 to order
Whats the No load consumption and efficiency?
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 7:23pm On Jan 17, 2023
viperVIP:
I need help here please.
I use a Growatt SPF 5000 ES,
Connected to 16s DIY LFP cells
And 16s 200a ANT BMS

At first, I set my charging voltage to 3.6 X 16 = 57.6v, float voltage to 3.5 X 16 = 56.0v,
but after so much information gathering here and there, I settled for 56.0v as charging voltage and 55.2v as float voltage.

But irrespective of the times I made the changes above, I am always having problems with the BMS. Sometimes it charges to 90% and stops charging, other times 38%, 68%, but if I reset the BMS, it will continue charging and eventually reach 100%.

This is now beginning to happen on daily basis, but before I go ahead and change the BMS to JBD, I want to be sure what could wrong please? I have sold the system to a client after few months use and I am beginning to look like a bad man now, energy initiates come to my rescue abeg grin
LFP cells don’t float stop confusing your Charger, use same voltage 55.6 for both Float and bulk.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 9:50pm On Jan 13, 2023
Juror:
I have these for sale:
Fangpusun 50D charge controller - 55k
Microtek 24V inverter - ups - 50k
Contact?
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 4:53pm On Jan 09, 2023
luvlyoracle:
Its meant to be 28.8
I feel i am still missing some juice cheesy
Extra Juice no dey after 27.6

Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 11:38am On Jan 09, 2023
luvlyoracle:
Good Morning all


Anyone here can suggest the cheapest way to charge a 24v 55Ah lifepo4 battery to fill...my 24v inverter stops at 27.7v�
Your battery is fully charged at 27.7v
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 3:49pm On Jan 02, 2023
AshipaEk0:
I have a mains charging setup with a small lithium battery and Sorotec hybrid

Discovered when the battery is charged full it stops charging and starts discharging quietly over a couple of days.

For example I've had grid supply for more than 48 hours (new year bonus) and checked my bms to see my battery has lost 25 Ah.


Is there something I'm missing? Or that's normal?
What's your charging profile,
Bulk and float voltage.

If your float voltage is too low, your battery may have to discharge some capacity.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 9:05pm On Dec 31, 2022
samnaija:
So according to your school of taught with lithium sun go balance.
If course, it can withstand deep discharge I run 2kw load on 5kWh 24V battery bank without thinking about killing the batteries, whether there is sun or no sun.

Boss its up to the person to decide!
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 11:20pm On Dec 30, 2022
samnaija:
This is very very wrong , and untrue.
Nothing wrong with flooded batteries running pumping machines. I will always say it , if you are currently not using flooded batteries stop trying to make it look has if it is a diseased patient.. stop lying. . period.
Where is the lie?

From my experience he is saying the truth, you cannot control Sun! Hence its risky to rely on it especially for heavy loads, those batteries will work but at the expense of his hard earned cash.
Technology Market › Re: Google Pixel 6a, 6, 6pro, 7, 7pro Deals by Dam5reey(m): 9:38pm On Dec 28, 2022
Appraizzal:
Do you have a shop? Location please?
Just message him to get details.
Super Legit, just order before it finishes
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 2:17pm On Dec 07, 2022
jonescosmo:
Batteries are connected in Parallel, RS485 Cable between Batteries (Using DIP switch for Battery 1: 10000 and Battery 2: 01001, and I made a special cable to link the Inverter and the Batteries.

Deye Inverters doesn't read Felicity Batteries out of box you will have to crimp a cable for CAN communication.
The Diagram for wiring the CAN communication between Inverter and Battery will be appreciated thank you.
European Football (EPL, UEFA, La Liga) › Re: Manchester City Vs Aston Villa ( 3 - 2) On 22nd May 2022 by Dam5reey(m): 9:41am On May 23, 2022
Soso990240:
when Madrid did a comeback against PSG, CHELSEA, and scored Man City 2 goals from 89 mins, all of u were shouting What a comeback! Madrid did that against but big teams oo. Now u don't believe Man City can make a comeback against small Aston villa? Chai.. una brain de pain una
You dey mind them, Lewandowski scored 5 goals in 9 minutes 1 player oo.. it was not fixed. now mancity scored 3 goals in 5 minutes, it became match fixing..
Phones › Re: How Do I Become An Android 13 Beta Tester by Dam5reey(m): 6:27pm On May 05, 2022
Chaos14:
The android 13 beta was released 9 days ago so i asked my self how do i get paid to test this shit
Buy Google phones, Enroll your device and move on, I have been on Beta tester, got tired this time around will wait for beta 2.. I use Pixel 4a
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 6:22pm On May 05, 2022
oldienavie:
Thank you.
Which of the 2 bolded do you suggest I go for and how come 200ah RITAR is cheaper than 100ah lifepo4?
It's not about the numbers...

There are more to it..

Do Research why Lifepo4 batteries are better than Lead acid, then make your decision..
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 6:22am On May 04, 2022
mank1234:
Hi guys,
Is there any BMS that can communicate with voltronic (axpert) Inverter?
SEPLOS BMS, RS485 communication do your research about it.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 7:15am On Apr 30, 2022
darediamond:
I hate giving Fish.
I prefer making you a Fisher Man with a Difference!

Never buy any how inverter. Buy Modern PURE SINE WAVE INVERTER alone. Inverter painted in Blue and Black are most times Pure Sine Wave Inverter.

Never buy Amperage Hog inverter that uses low frequency transformer(60hz/50hz) for dc to ac conversion.

The Heart and Back Bone Of Solar Gen Set is the Solar Panel not Inverter nor The Controller of any type.

Buy only MPPT controller alone and if you can Not afford Lithium Titanate Oxide Battery, Go for Lithium Phosphate or Worse Lithium Polymer.

** NEVER YOU BUY Lithium Ion Battery nor SLA or sealed lead acid battery oo. ** Never!!
Always use Thick Gauge, Insulated Pure Copper wire for your battery charging and Battery discharging.

For your 800W load, if you intend to simultaneously charge your batteries and still have enough power to power your intended devices,

Get at least 10 pieces of 200Watt Solar Panels
Get one peace of 24Volt 200AmpHour Lithium Phosphate Battery Pack
Get 150Amp Variable Voltage MPPT Solar Controller
Get one 4 Kilowatts Non-Transformerlles Pure Sine Wave Inverter or better still one 4KILOWATT Pure Sine Wave Hybrid Inverter.
Thanks boss, After reading this information I became a Fisher Man..
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 7:37am On Apr 27, 2022
mctfopt:
Currently use JK with 2A balance current. Two years and it's still kicking grin

Used it in both 24v system and 48v. Pretty great BMS
What's your balance open voltage?
Balancing at below 3.3V is just creating unbalance cells.
From 3.4V or below 3.0Vper cell is where balancing is necessary.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 7:08am On Apr 26, 2022
myrax7:
Good day,
What's the best advisable way to connect PV into 4 parallel inverters?
Can all 4 share 1 string PV input or do they all their own separate string of input
You have to use the Seperate input on the inverter.

If your string exceed the PV rating on one of the inverter, you can move part of the PV power to another inverter.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 8:28am On Apr 23, 2022
abilityC:
Yea, all the same ive gotten a 14kwh battery bank so i dont need more at the moment grin

Time is money... grin
Make sense, I did the same when things was better, got my cells shipped at better rates.. 272 USD + 20K for 8 cells.

Yours is about 4 times..
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 7:55am On Apr 23, 2022
abilityC:
I paid for express Air shipping because i wanted to get hold of my Batteries Asap and also clearing to be taken care of by the company receiving my consignment, first shipment took more days than expected due to Corona wahala in some key cities in China.
Both shipment under trading term of DDP, Convenient Delivery (You can receive the goods at the destination place, your supplier will do the import customs clearance at the destination port and also afford all the fees including import duty)

First shipment cost USD 991.93 for 8 batteries and other little components
2nd shipment cost USD 1,035.16 for same 8 batteries and other little components (16s Jbd BMS etc)
* i also paid extra 20k x 2 for the batteries to be flown from Lagos to Abuja

I paid for goods/shipping on March.3, 2022 but i received my goods 10th/4/2022 for 1st shipment
I paid for goods/shipping on Apr. 7, 2022 but i received my goods 22nd/4/2022 for 2nd shipment
Shipping alone is 2000 USD, this could have got your 10kwh batteries with inverter 5kw..

Just extra one month wait.. cheesy
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 12:39pm On Apr 19, 2022
siu4real:
Thank you so much......i intend using it for 6-8 hours.
Okay, I would recommend you keep the batteries same capacity.

Get a smaller capacity inverter and panels, but One thing is you will be thinking about upgrade within few months..

so if money is not an issue just close eyes and do the full off grid set up.

If not just do as you budget can carry on inverter and Panels.
1800w panel and 2.4kw inverter can be a starting point.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 10:47am On Apr 19, 2022
siu4real:
Good day all ....Please i need a help ,can someone tell or suggest to me what capacity of battery ,inverter, solar panel e.t.c will i need to power my .......

(1) .........Two ceiling fans and one standing fan
(2)........ four light bulbs
(3) ........one "42" inch tv
(4)....... phone charging
(5) .......One laptop

What are the recommended brand .
I would round the load up to 300w, if you intend to use this 24hours, then you need to cater for 7kwh daily..

if you intend to go off grid.
So you need Solar panels size of 3600w -
Inverter 24V, 3.5KW Sorotec
Batteries 5kwh LFP

Panels 750K, inverter 280K, batteries 700k.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 3:48pm On Apr 18, 2022
MontyNG:
huh huh huh
Abeg na... Try read my post before throwing out a reply.

I know my consumption. Its even right there in the post. I use roughly 10kw per day in the workshop and 30kw per day in the house.

My question was not how to measure my consumption boss... It was how to measure my pv generation and battery cycles for 1

And 2, recommendations for good and reliable sources of lipo batterily bank (aside from the jos guy)

I know my post is long, but abeg read am na... Or ignore it if its too long to read, understand and offer constructive or helpful answer
You suppose don ignore too, if my reply wasn't helpful.
I replied to part I understood.. peace
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 12:02pm On Apr 18, 2022
MontyNG:
So much knowledge here but I come again...

I'm not even sure where to start... But I'll narrate my full story and beg for help + guidance

Nepa in my area is pretty good. If it goes, not for more than 2hrs per day. Most days we get 24hrs. (But at almost N80 per kw, it's not affordable anymore! Hence the desire to go offgrid)

So the plan is to have two solar setups one for the house and the second for the workshop

Setup1(workshop): 8x 250 watt solar panels with 3 kva hybrid inverter. Now, I just bought 10kw lipo battery (2x 24v 200ah) rebranded blue carbon batteries.
The bluecarbon batteries has been rebranded by a local supplier. The guy na cool guy, but Mehn, these batteries has been disappointing ooo. They cycle twice each night... How is that even possible? Even the lead acid I replaced it with performed better when new.

But I am trying to be objective so now, I'm looking for ways to install some kind of monitor to log all the required stats. (my load average is like 600W per hr) but I want to monitor the whole thing before I head back to confront the supplier. I have it fully on Nepa bypass now so the 2 batteries are always fully charged and I'm monitoring my loads over the period of 1 to 2 weeks. Then I'll switch off bypass and see what the performance is. I can post results here.

Questions: Can I install passive monitoring for how much is being generated, battery charge and load.
Also, the hybrid inverter is rebadged from Arnergy. Is there a way I can get the actual model number so I can see the features and how I can connect a raspberry pi for monitoring.


Setup 2: 16x 350w Panels with a 5kva GENNEX (Aspert) hybrid inverter. (No batteries yet)

This is yet to be installed as I'm still gathering money for batteries. The load this will be powering ranges from 15 to max 30kw per day. Looking to slowly build up to 30kwh battery bank, since a good portion of the loads will be during the day so will be covered by the panels. Night loads is max 15kw.

Questions: Those bluecarbon batteries have been a let down... I don't even want to look at felicity as they seem to be in the same category with bluecarbon.
Is the "Jos Guy" the only person assembling batteries in Nigeria to a high quality? Are there any good brands to look at (aside from [$]Plyont£ch[/$] )


Looking forward to some guidance please
If you have Nepa for almost 24 hours, why are you then stressing about your consumption and analysis, just Load the Units and see how many you used in a month, use that to Size your Solar panels to generate the same.. it's as simple as that.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 7:21am On Apr 17, 2022
NiyiOmoIyunade:
Sometimes too much knowledge can be a burden grin grin cheesy


One issue with basic charge controllers is that they try to pass through the max possible solar charge to the batteries until absorb stage is reached - better SCC designs allow you to limit the battery charge amps specifically e.g Victron - thus I could have a 10kW array on a relatively small battery bank and allocate say 2kW to battery charging while the balance of available PV is used for day time loads.
Baba Blue Energy grin

It could have been Eg Deye hybrid inverter na, because it can also limit charge current..

Standard alone CC in your example is beginning to face out too.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 6:56pm On Apr 14, 2022
olopan:
Which BMS was stated in your pictures?
Daly BMS
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 4:03pm On Apr 14, 2022
Valto:
not available at the moment. meanwhile, only lithium can do this.. grin cheesy 62A charge on a 100ah 12V Lifepo4 battery pack.
Marketer, lol
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 11:53am On Apr 14, 2022
Hollawayn05:
Someone posted dis in a Whatsapp group, how viable is it?
Cos am certain a 40amps battery can't do half of the above mentioned
It's a good starting point.

For you to understand I need to go a little bit technically, if this is OFF Grid, that is no Nepa.

Generation is the key, you can only generate 400wh to 800wh..

Base your usage on the energy production, 500wh average, this mean on Daily basis
50w of load for 8 hours OR 25w of load for 16 hours. Basically depending on the load.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m):
microgiant:
Sometimes, I am just confused. What is the reason for the back and forth banter? Is it only Nigerians or it is the same world over. Someone posted is own opinion, suddenly it becomes a debate.

Most times people are advised to buy Lithium if they can afford it, otherwise buy LA while they plan for the upgrade in future.

May be the counter voices are dealers and are not happy with the reviews as it is not good for their business. lipsrsealed
The purpose here is to educate people who are just getting started, so they don't make mistake most users here made.. it's a discussion forum, debate is allowed cheesy

Considering all the factors, it's better to pay 2 times for batteries that will last 10 years+, example I arrange 12V 105A LFP for 150K
Compare it to LA that is 80K at the moment, do you know what the price will be in 5 years?

Just 5 years ago LA was around 80K for 200AH, now we all know the story..
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 6:42am On Apr 14, 2022
samnaija:
This your post is very biased, there is no dispute that lithium is the new baby in town, but don't disuade people from options they have.
First your statement above 800w solar system you want to push 50amps how ?..

All you described above is under panel size and you know it.

Lithium is great, but every one keeps saying the same thing. Pls be balanced. The only disadvantage of lithium which no one likes saying especially we wey dey naija na price....

Now someone will quote and say you can discharge lithium to 80%, you cant try that with lead, so it is cheaper. Why will I want to discharge batteries every time to this DOD, my battery bank is not adequate. Someone will say lithium loves to be discharged, everyone on this forum that have started their solar journey has an inbuilt fear of DOD. You should na money be batteries. Cycle life in batteries for both lithium or lead is what determines how long your batteries go stay.

It is comfort everyone dey find.
The best scenario either lithium or lead is to have a big enough and adequate bank size and have a reasonable amount of solar panels to charge it.
You mentioned you will be struggling to charge your batteries on a rainy day so you switch off for it to charge... Haha.! You know.
Both batteries and panels should be expanded to accommodate this.
Both lead acid and lithium are okay, they have their disadvantages and advantages,

Lithium is the future.
Lead acid is ok

Team tubular,
You have not provided any fact to back up your point, just like be pointed out, charging time, C-Rate, efficiency (meaning you harvest 1000wh energy the battery takes 970wh) unlike Lead acid that waste your harvest due to poor efficiency.

I use my 80 to 90% of my 5kwh bank without and fears
See the screenshot below, you can see my SOC another advantage, at 21% SOC check cell difference, Also the the Kind of Load I can throw at it regardless of the SOC, Observe the voltage drop only 0.3V.

If you have an existing set up with Lead acid, my message is not for you, it's only for those starting afresh.

Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 10:30am On Apr 13, 2022
isangjohnson:
[quote author=Penuelseun

Can't we do this thing without top balancing?
I'm not just comfortable with this balancing of cells.
If there is lithium battery that doesn't require balancing of cells, please let us know.
Until I see a lithium battery someone fixed and stayed for two to three years without balancing anything, I'll continue with my 50% DOD battery.
Top balancing is a one of Task!
Because cells don't have same capacity.

I have been using my cells for almost a year, no further top balance is required, cells remains close in voltage at the top end.

50% DOD is not cool at all, my cell still have 100% capacity I discharge mostly to 6%.. cheesy