Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 8:45pm On Oct 24, 2024
If you can afford the inverter freezers great go for them.

You can go for any of these;

1. LG (confirm if fouani has the normal type in stock as they only had the tall standing ones the last time I checked.
2. Haier Thermocool (check around for their authorized dealers)
3. TCL or Aeon (check jamara homes website).

If you can't afford the inverter models at this time, buy the normal/non inverter ones and reduce the thermostat from 7/8 to 5 this way you won't need to manually turn them off all the time and with a small battery bank you are sure of constant power to the freezees and enough battery juice to start your day with.

I prefer a higher wattage Solar panel as it reduces the need for bigger roof space and hybrid inverters with high voltage PV.

bkuranga:
What solar setup would you guys recommend for a frozen food business on a budget?

Aim is to use 2 freezers.

Do you have any efficient freezer you can recommend too?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 8:23pm On Oct 24, 2024
Felicity is ok
SRNE and Glowatt are also solid brands you should consider.

bkuranga:
Thank you.
This breakdown will help a lot.

Could you please recommend an inverter to use for this?

I had a guy recommend hybrid Felicity inverter offline, do you think this is a good option?
So sorry for the too many questions already.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 8:19pm On Oct 24, 2024
Based on personal experience, I'll say yes, inverter ACs are worth the extra bucks.

I have 3 inverter ACs (2x TCL 1HP and 1x Haier Thermocool 1HP) which are always on the lowest inverter model and consumes max 1.2kw/h.

When not on inverter mode the figure is over 2.4kw/h.

ojesymsym:
Inverter ACs vs Regular ACs?

Are the inverter ACs energy efficient enough to justify their extra cost over regular ACs, which are also getting fairly energy efficient on their own?

What are your thoughts folks?
Technology MarketRe: House Clearance Sales.. Come In Here!!!! by Ferdiwar: 7:18pm On Oct 22, 2024
Contact please

Ernesthugo:
I HAVE BABY CAR SEAT BRAND NEW 15K ONLY
Technology MarketRe: House Clearance Sales.. Come In Here!!!! by Ferdiwar: 6:44pm On Oct 21, 2024
More pictures of the Baby car seat and center rugs.

Your contact is not on Whatsapp.


NarnieSnyper:
Direct UK-Used 32 inches Samsung LED tv. Never been used in Nigeria.
Model no. UE32D4010 - 55k

Baby Pram and car seat in clean condition- 12k

360° Swivel Office chair - 50k

Soccer balls and Basketballs - from 5k and above depending on the aesthetic

Centre Rugs of different shapes, colours and sizes in very clean conditon.

Location: Ijeshatedo/Cele, Lagos
Call: 0703-zero-5-four-7161 or check profile to text me on WhatsApp
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 8:56pm On Oct 07, 2024
They are genuine panels.
Currently using the 625w I got from them.

Thunderbolt:
Good evening house.

Need some help please.
Trying to get some 555W Jinko solar panels from Fouani at 130k each.
Please does anyone in the house have experience with panels from Fouani?
Wondering if these are genuine products.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 9:38am On Oct 06, 2024
The fuse is for the coil of the relay

Namzy:
Fuse not required
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 9:42pm On Oct 02, 2024
This is exactly what came to my mind and the thing is that when it's other people that's doing it to their systems that they can't DIY it gets labeled as by bad work.

HeavenlyBang:
No difference between wetin some of una dey do and wetin kazeem mechanics dey do people cars grin

If it works for you, congratulations though. Life no suppose hard.
Technology MarketRe: Diy Lithium Ion Like-minds by Ferdiwar: 7:36am On Sep 11, 2024
It depends on what you intend to use it to achieve.

You can get the BMS from vendors here or AliExpress

Southboy:
I just got 360 pieces of 18650 batteries, please how many bms would you recommend I buy plus where can I get it. Thank you
Technology MarketRe: Diy Lithium Ion Like-minds by Ferdiwar: 7:31am On Sep 11, 2024
You can achieve this by replacing the wires from inverter output with the wires from inverter ON switch at the relay connection.

ajabani4allah:
That part "put off the inverter" pls can you shed more light on this? I have a 10A 8pin DIY relay I am using but it can only transfer the load but not put off the inverter. Can the relay achieve this? I need something that can also put off the inverter when I am on grid to save my battery from ideal power consumption of the inverter
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 7:01am On Sep 11, 2024
A friend of mine that is based in Enugu told me that the state governor is currently taxing people using Solar when I tried to convince him to go Solar.

I'm yet to validate this claim Sha.

JustCryptos:
Don't be surprised if the government introduced Solar tax.
Technology MarketRe: Diy Lithium Ion Like-minds by Ferdiwar: 8:17pm On Aug 22, 2024
Why do you prefer Daly BMS?

tetralogyfallot:
Ready for installation
Technology MarketRe: Diy Lithium Ion Like-minds by Ferdiwar: 8:16pm On Aug 22, 2024
You can check off grid garage.

He has interesting videos

capnies:
Wonderful brothers please can you recommend a YouTube channel where I can learn this DIY lifepo4 battery building or teach me or both. Please
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 8:35pm On Jul 11, 2024
I believe Deye inverters has a function that activates an over discharged battery.

Correct me if I'm wrong.

jonescosmos:
It's possible that it has discharged below BMS Cut off Voltage, so you might have to Jump Start it.

To do that, you will need a DC Power Supply, Open the battery and Clip your DC Power Supply to the Battery Main Terminals leading to the BMS.
Adjust your Voltage to the Nominal Voltage of the Battery Pack. Turn on your Lithium Battery by its switch.

The DC Power Supply will confuse the BMS to think that your Battery Pack has not discharged and turn on the Mosfets.

Once the battery turns on, start power up your charge source to start charging your battery then remove the DC Power Supply.

You can also charge the cells directly using this method but this is only if you know what you are doing.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 8:30pm On Jul 11, 2024
RESOLUTION UPDATE.

Finally I've been able to resolve the issue I was having with my inverter.

Apparently the inverter only needed a factory reset due to the software update performed on it by Deye.

Special thanks to @Jonescosmos for all the assistance and for also intervening when Mr. Fadi @ Solarco was understanding my English grin.

I truly appreciate you Boss.

Thanks to everyone who gave their 2 cents on my case you guys are the Best.

Ferdiwar:
Update on my setup.

Sometime last month I connected all my AC to the smart load of my inverter, and noticed that the inverter was going off and on repeatedly for like 5x before stabilizing back on. This would happen severely in a day before the sun goes down as I discovered it only happens during the day.

As a result I reverted back to the previous connection and disabled the smart load thinking that was my issue, but it still persisted, so I did some reading online and concluded it might be a software bug.

I emailed Deye and requested for diagnosis and update which they did by pushing a remote firmware update to the inverter, yet the issue continued (in my mind I was like I spent huge money to buy a faulty batch of an expensive inverter). I sent an update email yesterday to Deye explaining that the issue is not yet resolved (yet to get an update though) after it happened for the 2nd time in the morning (around 11am). At this point I thought it wise to calm down and observe the inverter when next it happens rather than be angry, so I stayed put in front of the inverter and watched it.

Few minutes later it happened again this time around I was watching the screen and boom I caught it in the act and it happens to be that the voltages of 2 strings of panels attached to the 2 MPPTs of the inverter exceeded the max 500v of the inverter (string 1 5x Longi 570w panels was pumping 240v+ as at that time while string 2 5x Jinko 625w panels were pushing over 265v both exceeding the 500v max voltage).

As I saw that I quickly switched off string 1 breaker and the inverter stabilized instantly which suggests that the input of the 2 MPPTs are somehow connected in series or something like that as one of the MPPTs can take 500v alone but the 2 MPPTs combined together is still 500v.

No matter what you do, do not exceed the max voltage of your inverter and take not of the tolerance of the VOC of your panels when connecting your panels to your CC or inverter to avoid stories just in case your inverter or CC is not equipped to handle any form voltage spike above the rated max voltage of the inverter or CC.


@Jonescosmos the 500v is for the 2 MPPTs after all
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 8:12pm On Jul 11, 2024
I was over happy when I saw it and truly appreciated spending the amount I spent then to buy it.

I'll maintain the 5kwh as advised for compatibility purposes.

jonescosmos:
Deye no fit make that mistake na. grin
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 8:06pm On Jul 11, 2024
Yes it's in the attachment I shared.

mctfopt:
Don't leave us hanging, is there one?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 7:50pm On Jul 11, 2024
Deye 8kva inverter is around 2.6m.

Oshomo12:
How much is brand new one?
How long has it been in service?

10kva Deye with dual mppt will just be a little higher than the 1.8m
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 9:13am On Jul 11, 2024
I read about the effects of in-rush current and the damages it can cause to inverters, I opened my battery to confirm that it was fitted with a pre charged resistor grin.

jonescosmos:
Don't waste your money going to buy another Inverter. The problem is that the IN-RUSH Battery Current damaged the DC Bus Gates of your inverter which is likely to continue even if you buy another Inverter. That spark your noticed was supposed to be absorbed or suppressed by the Pre-Charge Resistor first and softly starts the Inverter LV DC Bus Circuit.

Newer Cworth Batteries has an RJ45 type Pre-Charge Resistor that you can plug into the RJ45 Port to limit the In rush current. Some other Lithium Batteries has the DIP Switch type of this Resistor that you can toggle to on and off.

If your Battery has an RJ45 Port, I would suggest you approach Cworth Service center to grab this Resistor. If your battery does not have an RJ45 Port ask them for a Pre-Charge Resistor or you can buy one to retrofit in your battery.

Every Installer, DIYer, etc is supposed to have this Resistor because some Warrantees does not cover damages caused by In-Rush Current. Take note.

You can google how to protect your Inverter from in-rush current for more info.

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 8:11am On Jul 04, 2024
Sorry for the sad experience. I usually call or chat them to confirm availability before placing orders.

You can also explore other options like Longi from Solarco in Abuja (Mr. Fadi is a very helpful and reasonable person).

isangjohnson:
Let me cut the long story short. That was the available pv.
I was planning to use 2 pcs of 580w Junko pv but the of trouble/stress of bringing them down to Uyo from either Abuja or Lagos was too much.
As I'm typing this, I've 5 pcs of 580w Jinko pv in Abuja and I'm told to pay 30k each for the waybill.
Again, I checked and saw 580w pv in fouani store website on the 12th of last month and I made payment for 5 pcs. The following day, I was called and told that the 580w was out of stock. There was no higher watt pv and my customer didn't want to go for a lower watt pv.
I called for a refund and I was told to go my bank and apply for charge back. I went and applied and my bank later told me the money is already in the fouani store account that there's nothing the bank can do.
I called fouani customer service and I was told to wait. They later called me that the money was refunded to my account on Monday this week. I checked my app and I didn't see it. I will still go back to my bank and print account statement.
I will NEVER EVER buy anything from fouani store again. The stress of getting a refund is unbearable
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 7:46am On Jul 04, 2024
Mine is similar to this with small difference.

Deye SE-G5 1 PRO 5.12KWH 48V
jonescosmos:
Inside Deye SE-G5.1 PRO-B 5.12KW 48V

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 7:11pm On Jun 28, 2024
Always detailed and on point.

Kudos.

jonescosmos:
Sorry for this terrible experience bro.

You need to tweak up your installation if you must continue to use Solar and Inverter while living in that building.

1. You need a rain sensor switch. Most rain-sensing devices work by accumulating a set amount of rainfall before a switch is activated that interrupts the circuit from the controller and shuts off the system.

2. You need a contactor style of ATS that disconnects your Grid Input once Grid is Off which is most likely to happen once it starts to rain. Also in the same box, you will integrate a PV Rapid Shutdown Contactor that will be connected to the Rain Sensor. Once the sensor gives the command, these contactors will shut off all inputs to your Inverter.

3. You need to drive a 6ft or 8ft earth rod into the ground and use it as your earth if the building does not belong to you.

4. You need the appropriate SPDs, AC & DC RCBO MCBs for your PV, Inverter and Home loads. By appropriate I mean the amperage ratings must be appropriate to you devices. Eg. Don't go putting a 63A MCB between grid and your Inverter when your Inverter Input Current is rated 25A Max.

5. You need an experienced electrical personnel to do this connections. No need to go this route if you will not use a qualified technician to install them.

Though this might sound expensive, It's better than replacing or repairing your Inverter every rainy season. It's a must in Renewable Energy if you must use it.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 10:17am On Jun 18, 2024
50A

mank1234:
What was the maximum discharge current value in the inverter before?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 10:35pm On Jun 17, 2024
Thank you for your response.

The max charge/discharge current has always been on 0.5C since installation and the only thing that needs surge startup is the fridge as all my ACs are inverter AC. I'll adjust the the max discharge current to 115A and see how it goes.

mank1234:
For number 3, go to settings, then battery, scroll to the second page, it has figures for maximum charge current and maximum discharge current.

Maximum charge current - set to anything you want. This is not important since your panel is not more than 6500w.
Maximum discharge current, leave it at 115A to accommodate startup surge of some appliances. If you set a lower limit, DC overcurrent will be reported when you try to draw more than that value from battery. But be sure that your total connected load is not more than 5kw.

If the above was already correct, (ie discharge current 115A limit) then the issue is number 1 as earlier stated.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 6:52pm On Jun 17, 2024
Kindly explain more of the No 3 please.

As for No 2, the total installed panels are not up to 6,000w.

The installer will be coming over the weekend to carryout a check to determine if there's a short circuit to frame or anything like that.

mank1234:
It's the same error. The number may be different in different model. And the cause is what I told you before. 1) Your panel is exceeding 17A Isc during favourable condition and your controller is thus unable to clip the Imp to 13A.
Or
2) Total wattage at that point is in excess of 6500W and the unit is unable to handle the excess.
Or
3) Your discharge/charge current limit is too low relative to load and panel size.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 6:44pm On Jun 17, 2024
5x 570w Longi panels and 5x 625w Jinko panels.

swagifted:
impressive...how much panels do you have on it?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 1:40pm On Jun 17, 2024
No but I just discovered that it threw this error code instead F14 DC_OverCurr_Fault.

jonescosmos:
Did your Inverter throw this F20 Tz_Dc_OverCurr_Fault Error Code?

Check from device info page and see.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 1:13pm On Jun 17, 2024
On average over 20kwh on a sunny day and about 15kwh on a cloudy/rainy day.

swagifted:
how many kwh do you generate in a day.?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 12:36pm On Jun 16, 2024
Yes mine is the SUN-5K-SG03LP1-EU model with 2 MPPTs.

The Longi string is connected to MPPT 1 while the Jinko string is connected to the MPPT 2.

Will have the installer check for leakage to the frame when he's back.

jonescosmos:
Please post the side sticker of your Inverter, or send the specific datasheet or model of your inverter.

From the pictures you attached your model is either SUN-3.6KSG03LP1-EU, SUN-5KSG03LP1-EU or SUN-6KSG03LP1-EU

If yes, then bolded is a confirmation that your inverter has just 2 MPPT with 1 string each and both trackers should be independent with a Max ISc of 17A each.

I hope one of your PVs is not shorted or leaking power to the frame.

Please take a look at the attached Datasheet.

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 2:02pm On Jun 12, 2024
The MC4s are crimped and connected correctly.

I did some testing and discovered that only the negative of the 2 MPPTs are connected in parallel, while the positives are independent of each other.

I'll have to disconnect one of the panels pending when I resolve the issue.

jonescosmos:
Then it's possible that your MC4 connectors crimping is wrong. Before looking inside the inverter,
Make sure that the Negative Cable coming from your PV (after leaving your breakers and spd box, if any) is crimped with a Negative MC4 connector which will plug in to the Positive MC4 connector (PV-) on the body of your Inverter like wise the Positive PV Cable is crimped with a Positive MC4 connector that will then plug into the Negative MC4 connector (PV+) on the body of your Inverter.

Everything should work well after making this correction.

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 3:51pm On Jun 10, 2024
I believe something is wrong then.

I'll do an indepth diagnostic on Wednesday and update you on my findings.

Thank you so much for all the responses so far.


jonescosmos:
Take a look at my Voltages on both Inverters this morning as promised.
2x 8KW According to the MPPTs and their Strings as I outlined earlier.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by Ferdiwar: 3:44pm On Jun 10, 2024
Exactly.

@Jonescosmos please keep the detailed explanations coming.

mctfopt:
I like his replies, I like detailed replies. Leaves no room for doubts.