Thank God for safety of life's of those around, else it could have been another sad story for all |
The lead-acid battery handle dey show if one looks carefully at the see-through holes. HeavenlyBang: |
You need to understand that some banks did their installation when panels were 300 - 350 W. and so they are little as they were the latest at the time, with 18-19% efficiency At least a recent project for sterling bank, used 550W in the deployment bassdow: |
1. you can install an inverter AC to cool the room down 2. Use an injector and extractor fan. [The injector fan brings cool outdoor air; let's say it's placed around a tree and extractor takes the heat away.] It can even make more sense if it is temperature and humidity controlled. yvy1: |
There is Feeo brand in case you need it. there is no 30A only 32A Machiny: |
Let's reduce the charging voltage to 54.5 , float at 53.5v and leave other settings. lets see how that goes quote author=Collione post=136184945] Good morning . So sorry for the delayed feedback. Because of the way the battery was placed getting a picture was tricky. Please find attached. Thank you[/quote] |
All is fine from this angle if the battery is a 16s battery. can you please send a picture of the sticker on the battery? I am having this feeling it's a 15s battery. @15s the batteries will all be more than full, which is 3.68V instead of sticker of 3.65V, which for long-time usage is pretty bad. Collione: |
It's good that you were proactive to turn off power sources. What voltage was displayed on the battery screen? Please share your inverter parameters/settings for verification, in case there is a mistake. alarm; full, Power/supply over voltage warning [ it think]:pOVW sOVW, protect mechanism enaged; pOVP Collione: |
Make COU or cut-off Voltage to 48V if it can go that high, but if not, make DTA 49V. while CU is 55.2 and FLU is 54 ...... This is a more conservative battery parameters for 16s LIFEPO4 Battery Collione: |
You need to check the manual for a more in-depth explanation of the lockdown voltage. But in my own opinion, I believe you should set the lockdown to 48V for safety or precaution. Collione: |
Do a complete system reset to reboot your new setting with startup and see if the battery will accept the charge. Also to note is that if your current is high, it may be rejected, so watch out for that too. ask4bk: |
If you haven't done your installation, i will strongly suggest going for only 9 panel for those to be used in series. If case 10 is to be used, say 5 panels in series and then have them parallel; these arrangements could likely damage the inbuilt MPPT if the Isc is more than that of the inverter's MPPT. The best you should do is watch out! BTW, if you need a quote and installation with every bell and whistle that's going to keep your investment safe, be sure to reach out to me via contact in bio. algomachine: |
There was a problem on site regarding error E5 on Indian inverters, which we experienced on a site, and I want to gladly share the solution with you. We've made this <a href=" https://www.youtube.com/watch?v=9bjA3mge48U">link</a> to point to "Talk with OgaSolar YouTube page. |
I don't really know what could be the issue, but then fingers can also be pointed to the surge since you said it rained. obinna37: |
This may be likely error 53 or 06, which is related to unstable output voltage You should consider taking it to a repair centre. BTW, did you use sometime slightly heavy on it? obinna37: |
E still dey fire 5 years plus after installation. perform have drop due to weather no doubt but every little wattage counts dollarnaira: |
It was last sold for 118k when I bought it last year for a colleague. Request a price list and see if it is available there. EduTechTainMent: |
Try VMpower 1.5kVA 12V sold by Techland; I have one operating for 2 years+ now. It handles surges pretty okay. Just ensure you have enough panels or a strong battery because of the surge if the fridge is used. Jefferyzz: |
Can you please share pictures of the panels, i have a feeling i may have used its kind quote author=burnerr post=135772677]Good evening house. Has anyone here used ZnShine panels and can they kindly give a review of it's efficiency? Thank you in advance.[/quote] |
If it is assumed that the 6kW are all in series and your Isc or Imp is lower than 20A then using a 20/25A DC breaker is a good way to go. Likewise, for your inverter a 160A mccb is highly recommended. But if there are other factors to consider then, those could be stated. Ahyjo: |
It has a working communication and above all, it has full capacity quote author=Drgreatone post=135085524] What's ur review of the vestwoods battery seeing as u mentioned it here over the more common ones like feli, sms, cworth or sako?[/quote] |
This is a video i reviewed on Growatt Es5000 with their 4.8 kWh Battery (Hope) We've made this <a href=" |
From the image you attached, I see it is a hybrid inverter you use. There is a need to reduce the charging voltage to 28.8V as opposed to the 31V you currently do have and float voltage to 27V. What is happening now is that your battery is undergoing an unprepared equalisation charging state, which should only be once a month. You will need to consult our manual to understand what i have written above. quote author=kuma007 post=135082431]Please I am not a technical person. I just need advice. Kindly advise me please. Attached is the pic of the UI of the inverter[/quote] |
that will be like 8-5% DoD or SoC So, too low to continue, else you may have to start looking for ways to wake the battery up kristien4: |
Hello! You will need a 5kVA/6kVA inverter hybrid (Deye, Growatt, Tbb) or conventional type (victron, Tbb, felicity) if you need to run both the AC and pump simultaneously But if you plan to be self-conscious and know you won't run both together, then going for 3.5 kVA is a better choice. For the ideal solar power, you will need around 6,500 Wp of solar panels (Jinko, JA, Longi, Canadian) and a 120A solar charge controller. Battery choice (Vestwoods, Deriy, Pylonytech, Growatt) Lastly, with your budget i see things coming together in a 3.5 kVA range, especially when inverter, solar panels and BOS are all factored in. quote author=Ahyjo post=135077118]Hello experts in the house. I’ve been following all the discussions diligently especially the recent ones with regard to the lithium batteries. I am about to upgrade my system to be able to take a 1.5HP AC and also my 1HP submersible pump. Please I need your advice on the appropriate inverter to get ( both KVA (minimum required) and brand ) , the best lithium battery (14-15kwh) and CC (if the suggested inverter is not hybrid), and lastly the appropriate PV array. Thank you. As we all know these things don’t come cheap, so it’s better for one to do due diligence before investing in them, and there’s no better place to get appropriate information like here. Please advise me based on experience and not brand specifications. My working budget is 3M - 3.5M Kindly advice please.[/quote] |
I have a different opinion! Something to note is that when you add panels in series in range of 500-1000V cable sizes like 6mm can work just fine and this is also related to most residential and commercial projects. HeavenlyBang: |
since this was fixed temporarily before when you had it disconnected, i will advise that you have a pv breaker and a battery breaker on the charge contoller so you can reset it everytime the error pops up. BigDickProblems: |
It allows input, the Loads, No of loads, hours of usage in day and night are what you are allowed to input your data Slazim: |
I think maybe this could be a flaw in the new Felicity charge controllers. BigDickProblems: |