Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 12:01pm On Dec 14, 2017 |
Call us today
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 11:57am On Dec 14, 2017 |
Conduit Pipe work ongoing. decking has been casted so we just have to run the pipes on slab. POP or ceiling will cover it.
|
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 11:06am On Dec 14, 2017 |
Have a Nice day ahead |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 8:38am On Dec 13, 2017 |
marygold: kindly assist send price of d above to marygold_28@yahoo.com Message sent |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 12:03pm On Dec 12, 2017*. Modified: 3:35pm On Dec 12, 2017 |
nicemuyoo: Bass on what you suggested can you give a detailed quotation , quantity, product specs , your best price for cables. Pls include all the wires necessary including 10mm and 16mm and their quantities Using purechem brand prefere. With you full business address and contact number sir. Thank you sir Purechem is not producing cable for now. It over 2months they produce last. I can only send coleman, Nigerchin or Kabelmetal. |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 11:23am On Dec 12, 2017 |
nicemuyoo: Bass on what you suggested can you give a detailed quotation , quantity, product specs , your best price for cables. Pls include all the wires necessary including 10mm and 16mm and their quantities Using purechem brand prefere. With you full business address and contact number sir. Thank you sir ok sir. send me your mail address |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 11:09am On Dec 12, 2017 |
nicemuyoo: Thank you so much for your throwing more light into it sir, Pls what are the 16mm and 10mm used for?? 10mm and 16mm is for load cable from changeover/cut-out to Distribution board. |
Business To Business › Re: Introduce Your Business by topsy23(m): 11:04am On Dec 12, 2017 |
|
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 9:32am On Dec 12, 2017 |
nicemuyoo: Pls what is your opinion Quote for cables needed to do wiring of two buildings 1. 4 3- bed flat 2. 4 1- bed flat
1. 1.5mm single wire red 35 2. 1.5mm single wire black 30 3. 1.5mm single wire green 16 4. 2.5mm single wire red 13 5. 2.5mm single wire black 13 6. 2.5mm Single wire green 2 7. 4mm single wire red 3 8. 4mm single wire black 3 9. 10mm single wire red 1 10. 10mm single black 1 11. 16mm single red 1 12. 16mm single black 1 For a standard 3bedroom flat the quantity of cable needed are: 1.5mm CABLE: RED 5coils x 4flat = 20coils It shouldn't be more than 3-circuit together with external wall light BLACK 4coils x 4 flat = 16coils Green should not be more 1coil is the electrician want to use it for traveler 2.5mm for socket RED 2.5coils x 4flat = 12coils It shouldn't be more than 3-circuit together with external wall light BLACK 3coils x 4 flat = 12coils 2.5mm Green for the earth 3coils x 4 = 12coils 1-BEDROOM FLAT (ROOM AND PARLOR) 1.5mm RED 2Coils BLACK 2coils 2.5mm RED 1coil BLACK 1coil FOR FENCE LIGHT 1.5mm RED 2coils (DEPENDS ON THE WAY HE LAID HIS CONDUIT PIPE) BLACK 2coils 4mm CABLES -This cables seems not enough for the project, although, i don.t know number of AC, WATER HEATER to be installed in the house. Again he.s using the cable for the for COOKER UNIT.. Thanks |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 9:30am On Dec 12, 2017 |
passe: Hi Topsy23,
I will appreciate if you can furnish me with the current prices of the following COMSTAR cables to wallex032003@yahoo.co.uk;
2.5mm 1.5mm 10mm and TV Cable Wire Many Thanks ahead.
your reply mail is wallex032003@yahoo.co.uk;
Mail sent..
Thanks |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 9:28am On Dec 12, 2017 |
nicemuyoo: Pls i need your opinion on this for cable wire alone N1.35M . Is the quantity excess or not?? Quote for cables needed to do wiring of two buildings 1. 4 3- bed flat all ensuite 2. 4 1- bed flat all ensuite.
1. 1.5mm single wire red 35 2. 1.5mm single wire black 30 3. 1.5mm single wire green 16 4. 2.5mm single wire red 13 5. 2.5mm single wire black 13 6. 2.5mm Single wire green 2 7. 4mm single wire red 3 8. 4mm single wire black 3 9. 10mm single wire red 1 10. 10mm single black 1 11. 16mm single red 1 12. 16mm single black 1 For a standard 3bedroom flat the quantity of cable needed are: 1.5mm CABLE: RED 5coils x 4flat = 20coils It shouldn't be more than 3-circuit together with external wall light BLACK 4coils x 4 flat = 16coils Green should not be more 1coil is the electrician want to use it for traveler 2.5mm for socket RED 2.5coils x 4flat = 12coils It shouldn't be more than 3-circuit together with external wall light BLACK 3coils x 4 flat = 12coils 2.5mm Green for the earth 3coils x 4 = 12coils 1-BEDROOM FLAT (ROOM AND PARLOR) 1.5mm RED 2Coils BLACK 2coils 2.5mm RED 1coil BLACK 1coil FOR FENCE LIGHT 1.5mm RED 2coils (DEPENDS ON THE WAY HE LAID HIS CONDUIT PIPE) BLACK 2coils 4mm CABLES -This cables seems not enough for the project, although, i don.t know number of AC, WATER HEATER to be installed in the house. Again he.s using the cable for the for COOKER UNIT.. Thanks |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 8:40pm On Dec 10, 2017 |
Happy Sunday to you all |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 4:09pm On Dec 06, 2017 |
segzy14: Chai! Penny wise Pound foolish they say. Pay me professional fee, you no gree. Now you have lost all that money to bricklayers posing as Architects / Structural / civil engineers. Construction is not all about measurements and block arrangements. This is a disaster |
Properties › Re: Construction Of A(Beautiful Edifice) 4 Bedroom Duplex In Abuja by topsy23(m): 3:59pm On Dec 06, 2017 |
segzy14: Chai! Penny wise Pound foolish they say. Pay me professional fee, you no gree. Now you have lost all that money to bricklayers posing as Architects / Structural / civil engineers. Construction is not all about measurements and block arrangements. What a disaster!!!! |
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 10:59am On Dec 06, 2017 |
Call us today |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 10:57am On Dec 06, 2017 |
Call us for design today |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 10:56am On Dec 06, 2017 |
Call us today..... |
Properties › Re: Current Prices Of Building Materials In Nigeria by topsy23(m): 10:56am On Dec 06, 2017 |
|
Properties › Re: Current Prices Of Building Materials In Nigeria by topsy23(m): 8:07am On Dec 04, 2017 |
|
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 8:45pm On Dec 03, 2017 |
|
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 1:57pm On Dec 03, 2017 |
Happy Sunday |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 9:43pm On Dec 02, 2017 |
everydaymail1: Hello, Please, could you assist with Coleman cable prices? How quickly can you deliver in lagos? Pls include answer in your mail. my email is everydaymail1@yahoo.com.
Thank you. You help a lot! attended to |
Properties › Re: Complete Package Design Drawing For Mech, Elect & Plumbing(MEP) with COREN Seal by topsy23(op): 9:40pm On Dec 02, 2017 |
Happy weekend |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 12:20pm On Dec 02, 2017 |
Happy weekend |
Properties › Re: Construction Of A 5 Bedroom @ Lekki, Lagos by topsy23(m): 11:50am On Dec 02, 2017 |
Boss it been a while now. I have not seen any of ur update on nairaland, Your number is not going thru also. Maybe u ve relocated to Canada I guess!!! |
Properties › Re: Construction Of 4 Bedroom Duplex In WARRI, Delta State by topsy23(m): 11:47am On Dec 02, 2017 |
Boss it been a while now. I have not seen any of ur update on nairaland, Your number is not going thru also. Maybe u ve relocated to Canada I guess!!! |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 7:41am On Dec 02, 2017 |
twinskenny: probably surface wire Even with surface wiring 100k can't be enough unless the electrician use 1.5mm CHINA flat cable for socket and lighting. There are other materials that goes with flat cable. junction box, clip, distribution, lampholder, distribution etc.... |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 1:52pm On Dec 01, 2017 |
|
Car Talk › Re: Michael Schumacher's Ferrari F2001 Sold For N2.8 Billion (photos) by topsy23(m): 7:08am On Dec 01, 2017 |
hmmmm.....just passing |
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 7:06am On Dec 01, 2017 |
Thanks for your call and patronage |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 12:41pm On Nov 30, 2017 |
nicemuyoo: bles by nicemuyoo: 11:51am
Dear All? What would be a rough estimate cost and quantity of Nigerian cable needed to wire a ; Four 3-bed room flat house Four 1-bed room flat house Cheers For a standard 3-bedroom flat 1.5mm RED 4Coils BLACK 3COILS 2.5mm for Socket and Water heater RED 4Coils BLACK 4COILS GREEN 4COILS Note: Above quantity depends on number of water heater 4mm for A/C and Cooker control RED 3COILS BLACK 3COILS GREEN 3COILS One Bedroom Flat 1.5mm Red 1 Black 1 2.5mm Red 1 Black 1 Green 1 4mm for AC, Cooker, Water Heater Red 1 Black 1 Green 1 |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 10:46am On Nov 30, 2017 |
Dremca: why not use underground tank because this poses danger. Pressure pump/Booster pump must be introduce when using underground tank and there must steady power supply for continuous water in the building. |