Welcome, Guest: Register On Nairaland / LOGIN! / Trending / Recent / New
Stats: 3,153,574 members, 7,820,061 topics. Date: Tuesday, 07 May 2024 at 09:12 AM

Solar Energy, A Complement To FTA - Satellite TV Technology (172) - Nairaland

Nairaland Forum / Entertainment / TV/Movies / Satellite TV Technology / Solar Energy, A Complement To FTA (2070516 Views)

UPS Back-up, Also A Complement To FTA / FTA Frequency / Cctv Installation A Complement To Fta And Solar Energy (2) (3) (4)

(1) (2) (3) ... (169) (170) (171) (172) (173) (174) (175) ... (1697) (Reply) (Go Down)

Re: Solar Energy, A Complement To FTA by rajo4real(m): 5:19pm On Sep 21, 2016
bodejohn:
Some years ago in my deep thought, I wondered how availability of water supply became a thing of the past.
I postulated in my mind that very day...that very soon, power availability will become like water...

Today, I celebrate Three solid years of uninterrupted night & day power supply here...
This is one of the most amazing things I have done with my hands...

Welcome to tomorrow...


Nice one bro... where have u been all these while
Re: Solar Energy, A Complement To FTA by bodejohn(m): 7:45pm On Sep 21, 2016
rajo4real:



Nice one bro... where have u been all these while

I've been around...I visit here quite often but I no get energy for small arguments again... smiley

1 Like

Re: Solar Energy, A Complement To FTA by anidat77(m): 7:48pm On Sep 21, 2016
Hello Gurus, my 6 pcs of (200W @ 24V) solar panels are going to be located through 100ft cable lenght from the Epsolar MPPT 40amps CC,
What would be the best option in terms of solar panel configuration (ie series or parallel) and wire size to reduce current loss and not exceed Max MPPT input voltage of 100v on a good sunny day.

I'm sure there are people here with my same set up maybe with shorter cable distances,but please let me have your suggestions.

@Kiekie...my wahala don dey plenty o....if not for leaking pockets that 80amps outback solar charger would have healed my sores on this issue.
Re: Solar Energy, A Complement To FTA by kiekie1(m): 8:21pm On Sep 21, 2016
anidat77:
Hello Gurus, my 6 pcs of (200W @ 24V) solar panels are going to be located through 100ft cable lenght from the Epsolar MPPT 40amps CC,
What would be the best option in terms of solar panel configuration (ie series or parallel) and wire size to reduce current loss and not exceed Max MPPT input voltage of 100v on a good sunny day.

I'm sure there are people here with my same set up maybe with shorter cable distances,but please let me have your suggestions.

@Kiekie...my wahala don dey plenty o....if not for leaking pockets that 80amps outback solar charger would have healed my sores on this issue.


Hmmmn, still trying to picture the name ? Mail/call me ASAP on your current budget so I can remember which of my clients again .. Thanks
Re: Solar Energy, A Complement To FTA by anidat77(m): 8:36pm On Sep 21, 2016
@kiekie Your Port Harc0urt client you sent rails breakers and MT50 CC meter to....through waybill. Sorry I didn't get to say thanks here...like they say..better late than never grin

kiekie1:


Hmmmn, still trying to picture the name ? Mail/call me ASAP on your current budget so I can remember which of my clients again .. Thanks

2 Likes

Re: Solar Energy, A Complement To FTA by kiekie1(m): 11:10pm On Sep 21, 2016
anidat77:
@kiekie Your Port Harc0urt client you sent rails breakers and MT50 CC meter to....through waybill. Sorry I didn't get to say thanks here...like they say..better late than never grin



Oooooo I now remember ! OK i appreciate .. Call me for discounted price of 80a fangpuson MPPT since outback cc is on the high side for now .. Thanks
Re: Solar Energy, A Complement To FTA by DMerciful(m): 6:21am On Sep 22, 2016
You need to provide this important info to enable right advice.
What is the Voc ( open circuit voltage) of the panels? Its written on the name plate of the panel
anidat77:
Hello Gurus, my 6 pcs of (200W @ 24V) solar panels are going to be located through 100ft cable lenght from the Epsolar MPPT 40amps CC,
What would be the best option in terms of solar panel configuration (ie series or parallel) and wire size to reduce current loss and not exceed Max MPPT input voltage of 100v on a good sunny day.

I'm sure there are people here with my same set up maybe with shorter cable distances,but please let me have your suggestions.

@Kiekie...my wahala don dey plenty o....if not for leaking pockets that 80amps outback solar charger would have healed my sores on this issue.

Re: Solar Energy, A Complement To FTA by abunafiu(m): 7:07am On Sep 22, 2016
bodejohn:


I've been around...I visit here quite often but I no get energy for small arguments again... smiley
I share the same opinion with you. but it's always nice to be around to come in when necessary.
congratulations on your 3 years energy freedom.
are u still on the 48v150ah battery bank?
what's changed in your set up.
Re: Solar Energy, A Complement To FTA by idsolar(m): 7:54am On Sep 22, 2016
idsolar:
FOR SALE: 1.4kva sukam. 1.5yr used. for sale due to upgrade. call/whatsapp 08033735359, 08098740141 now. N38k pere

still waiting for more calls
Re: Solar Energy, A Complement To FTA by bodejohn(m): 8:40am On Sep 22, 2016
abunafiu:

I share the same opinion with you. but it's always nice to be around to come in when necessary.
congratulations on your 3 years energy freedom.
are u still on the 48v150ah battery bank?
what's changed in your set up.

Nah...i dropped to the more efficient 36V setup.
I'm currently planning two levels of upgrade.

1. Installation of a Meter Hub & Ethernet MeterBus Converter
2. Upgrading the batteries to Trojan grin, the ones I have now tried for 4 years.

2 Likes

Re: Solar Energy, A Complement To FTA by kiekie1(m): 10:29am On Sep 22, 2016
bodejohn:


Nah...i dropped to the more efficient 36V setup.
I'm currently planning two levels of upgrade.

1. Installation of a Meter Hub & Ethernet MeterBus Converter
2. Upgrading the batteries to Trojan grin, the ones I have now tried for 4 years.

Trojans (L16 & J185P)will soon be in stock .. Will keep you posted !

1 Like

Re: Solar Energy, A Complement To FTA by bodejohn(m): 11:01am On Sep 22, 2016
kiekie1:


Trojans (L16 & J185P)will soon be in stock .. Will keep you posted !

Alubarika Marketer grin!!!

3 Likes

Re: Solar Energy, A Complement To FTA by kiekie1(m): 11:37am On Sep 22, 2016
bodejohn:


Alubarika Marketer grin!!!

I loyal my Oga .. ! Abeg do upgrade jooor , e don tey
Re: Solar Energy, A Complement To FTA by anidat77(m): 1:01pm On Sep 22, 2016
DMerciful:
You need to provide this important info to enable right advice.
What is the Voc ( open circuit voltage) of the panels? Its written on the name plate of the panel

@DMerciful......each panel has Voc 37.4V... 6 panels.
Re: Solar Energy, A Complement To FTA by DMerciful(m): 1:15pm On Sep 22, 2016
My recommendation will be to connect 3 string of 2 panels in series then parallel these 3 strings so that overall Voc will be 74.8V.(ie 2*2*2). This is best configuration for your system. 2 string of 3 panels will not work because the total voltage of 112.2V will exceed the CC 100V max limit.
anidat77:


@DMerciful......each panel has Voc 37.4V... 6 panels.

1 Like

Re: Solar Energy, A Complement To FTA by efuro(m): 3:01pm On Sep 22, 2016
the baby in the house is learning how to walk with DIY installation of 300w.

configuration:
2 Tata poly panels @ 150w each
24v microtek 1600w inverter
43ft 6mm cables
2 genus 100A battery (new)
2 ipower 100A battery (new)
Roy 30A PWM cc

I plan to up grade soon. am sure kiekie will be of help as I can read a lot of praises of the giant kiekie

1. my problem is that can I combine d two batteries (sealed) since they're new. I tink they have similar c10 charging rate.

2. can I used inverter to charge (with grid) same time with my 30A pwm cc?

waiting for help from nigerian gurus.

Re: Solar Energy, A Complement To FTA by efuro(m): 3:04pm On Sep 22, 2016
low cost measures

Re: Solar Energy, A Complement To FTA by efuro(m): 3:06pm On Sep 22, 2016
low cost condt.

Re: Solar Energy, A Complement To FTA by kiekie1(m): 3:55pm On Sep 22, 2016
Myhome solar panels super promo ;

150w mono-40000 poly-35000
200w mono-55000
250w mono-68000,poly-62000
300w mono-75000,poly-70000


Joy solar panels;;;
200w mono #55000
260w poly #65000
320w poly #75000
phocos PWM controllers :10a #9500
45a #70000 80a #100000


Valid till 30/09/2016
Re: Solar Energy, A Complement To FTA by kiekie1(m): 4:34pm On Sep 22, 2016
efuro:
the baby in the house is learning how to walk with DIY installation of 300w.

configuration:
2 Tata poly panels @ 150w each
24v microtek 1600w inverter
43ft 6mm cables
2 genus 100A battery (new)
2 ipower 100A battery (new)
Roy 30A PWM cc

I plan to up grade soon. am sure kiekie will be of help as I can read a lot of praises of the giant kiekie

1. my problem is that can I combine d two batteries (sealed) since they're new. I tink they have similar c10 charging rate.

2. can I used inverter to charge (with grid) same time with my 30A pwm cc?

waiting for help from nigerian gurus.

Yep u dey try.. Will be expecting your call when u ready k
Re: Solar Energy, A Complement To FTA by JohnKester: 4:56pm On Sep 22, 2016
kiekie1:
Myhome solar panels super promo ;

150w mono-40000 poly-35000
200w mono-55000
250w mono-68000,poly-62000
300w mono-75000,poly-70000


Joy solar panels;;;
200w mono #55000
260w poly #65000
320w poly #75000
phocos PWM controllers :10a #9500
45a #70000 80a #100000


Valid till 31/09/2016

Check your date: September stops at 30th.

Cheers

2 Likes

Re: Solar Energy, A Complement To FTA by efuro(m): 4:58pm On Sep 22, 2016
kiekie1:


Yep u dey try.. Will be expecting your call when u ready k


soon my OGA. I don taste good soup. solar good oooo.

am planning 2 300w & mppt. my big tanx
Re: Solar Energy, A Complement To FTA by kiekie1(m): 5:44pm On Sep 22, 2016
JohnKester:


Check your date: September stops at 30th.

Cheers

Thanks my Oga !
Re: Solar Energy, A Complement To FTA by anidat77(m): 9:59pm On Sep 22, 2016
DMerciful:
My recommendation will be to connect 3 string of 2 panels in series then parallel these 3 strings so that overall Voc will be 74.8V.(ie 2*2*2). This is best configuration for your system. 2 string of 3 panels will not work because the total voltage of 112.2V will exceed the CC 100V max limit.

Ok cool....just one more question, what wire size 6mm or 4mm etc do you recommend for a length of 100ft between CC and panels?
Isc is 8.80A while Imp is 8.18A on the panel.
Re: Solar Energy, A Complement To FTA by zeestone99(m): 12:36am On Sep 23, 2016
Brand new microtek pure sine wave 900va inverter 4 sale, 37k. Cal 08117398294 for negotiation.
Reason 4 sale: owner upgraded to a 24v system n didn't bother using the 12v inverter at all.

Re: Solar Energy, A Complement To FTA by DMerciful(m): 6:29am On Sep 23, 2016
I will recommend 6mm-8mm
anidat77:


Ok cool....just one more question, what wire size 6mm or 4mm etc do you recommend for a length of 100ft between CC and panels?
Isc is 8.80A while Imp is 8.18A on the panel.
Re: Solar Energy, A Complement To FTA by kiekie1(m): 9:18am On Sep 23, 2016
DMerciful:
I will recommend 6mm-8mm

Hmmmn , he can manage that for now since panels aint much on PWM but i feel 10mm ought to be his least for that distance on a 24v inverter VDC system and for futuristic upgrade sake ! He can contact me if he needs 10mm×2 flex copper fire resistant armoured solar cable... Cheers
Re: Solar Energy, A Complement To FTA by JohnKester: 12:20pm On Sep 23, 2016
kiekie1:


Hmmmn , he can manage that for now since panels aint much on PWM but i feel 10mm ought to be his least for that distance on a 24v inverter VDC system and for futuristic upgrade sake ! He can contact me if he needs 10mm×2 flex copper fire resistant armoured solar cable... Cheers

Valid points.

Rather than strip all cables to rewire when he wants to upgrade, he can just go with 10mm now which will also give him minimal loss given the distance.

Cheers

1 Like

Re: Solar Energy, A Complement To FTA by DMerciful(m): 12:42pm On Sep 23, 2016
This has nothing to do with the inverter voltage. 74V between the panel and CC is high enough to offer lower current flow and as such lower cable diameter. ofcourse btw the CC and batteries needs to be thick and short as possible. 8mm wire is pretty thick for 74v for a distance of 100ft
kiekie1:


Hmmmn , he can manage that for now since panels aint much on PWM but i feel 10mm ought to be his least for that distance on a 24v inverter VDC system and for futuristic upgrade sake ! He can contact me if he needs 10mm×2 flex copper fire resistant armoured solar cable... Cheers

1 Like

Re: Solar Energy, A Complement To FTA by Saipro(m): 3:28pm On Sep 23, 2016
DUNKA:
Was just going through this old post on the argument on use of bottled water vs. Distilled water. Please there are companies that bottle and sell distilled water. Use distilled water for flooded batteries for longer life. Please see product below bought here in Jos sold in 1litre containers. Treat your batteries well and they will treat you well and last a long useful life cheesy

cheesy cheesy cheesy

I remember that discussion. 'Twas a heated thing at the time. Learnt to be less vocal thereafter. I'm still very much around, just kinda quiet. But I'd rather be wrong than not learn.

Thanks for reminding me of the reason I'm here
Re: Solar Energy, A Complement To FTA by battleaxe: 3:30pm On Sep 23, 2016
@bodejohn, dmerciful, pranil, all etc.

Is it possible to get 130W from a 130W solar panel?

Thanks.
Re: Solar Energy, A Complement To FTA by Monlo(m): 3:37pm On Sep 23, 2016
battleaxe:
@bodejohn, dmerciful, pranil, all etc.

Is it possible to get 130W from a 130W solar panel?

Thanks.
Nope,since there will always be energy loss,mind you energy efficiency is never 100%,but you can use an mppt cc to maximize your wattage output.RE rules,one love all.

(1) (2) (3) ... (169) (170) (171) (172) (173) (174) (175) ... (1697) (Reply)

FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread

Viewing this topic: ebrymDIY, Amador1, loluskysat(m), olaztek(m) and 1 guest(s)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 46
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.