Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JUO(m): 7:09pm On Sep 10, 2016 |
DUNKA: Finally finished up the install see pictures below.
Also any chance that the cost of panels will come down this year or early next year?  see millions  |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JUO(m): 7:00am On Sep 10, 2016 |
Braaad: Thanks very much for this... the 2x2 config should give me abt 90voc. but I suppose mppt cc is most efficient when voc is about 1.5 or 2 times the battery voltage. In this case im having 24v batt with 45voc panel array (which is abt 1.5 to 2 times batt voltage). I could be wrong though...can you explain more? 45v voc means there is no load on the panel. Imp means there is load on the panel. Since your panel is rated 24v, your imp should be around 36v at peak (1-2pm) during off peak your panel will operate below 28v which is very close to the battery voltage making your system to understand perform. In all cc is underutilised or are the panels not connected since you are working with 45v voc? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JUO(m): 5:33pm On Sep 03, 2016 |
chris81964: Where do you plan on using a grid tied inverter? maybe South Africa? |
Phones › Re: Recharge Card That Works With All Network by JUO(op): 8:22pm On Aug 25, 2016 |
yarimo: @ op this is nigeria, will it work in Nigerians sim? yes sir. Works with 4 GSM network in Nigeria
|
Phones › Recharge Card That Works With All Network by JUO(op): 3:21pm On Aug 25, 2016 |
Technology, all in one recharge card. Buy and load to any network. You don't need to worry about specific network. Just buy and load with the network code provided
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JUO(m): 3:16am On Aug 20, 2016 |
DUNKA: Goodday all just to give an update on my solar setup. Thread has been a bit too quiet.
8 Yingli Green Energy 250W PV Module(2000W) 4 Solar World 255w (1020w) 1 Outback Solar Charge Controller 80A 1 Outback Inverter Charger 3000 Watt 48VDC VFX 4028
8 Mercury flooded tubular Batteries 220Ah 1 10 Kva Prag servo stabilizer 1 BLS desulphator 48 v 1 battery kill isolator switch 1 trimetric 2030 1 Lightning Arrestor 1300 midnite solar A. C surge arrestor 1 300 midnite solar D. C surge arrestor Various Solar Accessories
Total Price:  you and Abu want make we thief? |
Autos › Re: Nigeria Used Lexus Rx330 2004 MODEL by JUO(op): 5:59am On Aug 06, 2016 |
no longer selling |
Autos › Re: Nigeria Used Lexus Rx330 2004 MODEL by JUO(op): 6:07am On Aug 02, 2016 |
Still available |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JUO(m): 8:16pm On Jul 29, 2016*. Modified: 8:34pm On Jul 29, 2016 |
[quote author=Dreamflyin post=47990882][/quote]mppt charger controller available. 15a-100a. 12v-60V-o8o-98733709 |
Autos › Re: Nigeria Used Lexus Rx330 2004 MODEL by JUO(op): 5:54am On Jul 29, 2016 |
check |
Autos › Re: Nigeria Used Lexus Rx330 2004 MODEL by JUO(op): 9:54am On Jul 28, 2016 |
available |
Autos › Re: Nigeria Used Lexus Rx330 2004 MODEL by JUO(op): 1:45pm On Jul 27, 2016 |
selling to buy RX400 |
Autos › Re: Nigeria Used Lexus Rx330 2004 MODEL by JUO(op): 10:00pm On Jul 26, 2016 |
NnadyAutos: Plz where in Delta State so I can come for inspection,send SMS to 08131012103. OK |
Autos › Re: Nigeria Used Lexus Rx330 2004 MODEL by JUO(op): 3:18pm On Jul 24, 2016 |
Check again |
Autos › Re: Nigeria Used Lexus Rx330 2004 MODEL by JUO(op): 5:39am On Jul 23, 2016 |
obitryce: where in delta state are you? Already receiving useless messages cos of the number is posted here. Please call or drop your contact I will call you Learn a new business: I want to inform you of a Free Business Seminar tomorow in Benin-city at C41 Hotels, 41 Adesuwa road, G.R.A. More info 08117390242. 9:30am |
Autos › Re: Nigeria Used Lexus Rx330 2004 MODEL by JUO(op): 5:37am On Jul 23, 2016 |
Carbaby007: 1.950m? A very big thank you, but no sir |
Autos › Re: Nigeria Used Lexus Rx330 2004 MODEL by JUO(op): 5:34am On Jul 23, 2016 |
|
Autos › Re: Nigeria Used Lexus Rx330 2004 MODEL by JUO(op): 7:03pm On Jul 20, 2016 |
call |
Autos › Re: Nigeria Used Lexus Rx330 2004 MODEL by JUO(op): 10:33am On Jul 19, 2016 |
location? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JUO(m): 4:48pm On Jul 18, 2016 |
|
Autos › Re: Nigeria Used Lexus Rx330 2004 MODEL by JUO(op): 4:17pm On Jul 18, 2016 |
IN |
Autos › Re: Nigeria Used Lexus Rx330 2004 MODEL by JUO(op): 2:07pm On Jul 17, 2016 |
CHECK |
Autos › Nigeria Used Lexus Rx330 2004 MODEL by JUO(op): 11:04am On Jul 17, 2016*. Modified: 6:00am On Aug 06, 2016 |
FEATURES:
Leather seat
Automatic transmission
Factory fitted AC
Rare AC vent
Power window
Sound engine
New tire
First body
Location Delta State
Price: 2.2m (asking price)
For inspection call : . used once a week since it was bought
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JUO(m): 5:10pm On Jul 09, 2016 |
Suko92: Hehe ,sorry my mistake den, am stil learning when it comes to solar/inverter installation. Though am using 125watts panel on my 100amps battery with 20A mppt cc n its been working fine for me n thinking of adding more to it, ur explanation as for d watts panel to be used to above ? Wil be appreciated. Tanx  I don't know the make of your battery and I don't know if the cells can take 20a. Just add one more 125-130w to stay within the range of 10-15a the avoid what you have in this picture
|
Politics › Re: BREAKING: Court Affirms Removal Of ikpeazu by JUO(m): 7:37pm On Jul 08, 2016 |
Which kin thing be this, Are they playing with us? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JUO(m): 4:55pm On Jul 07, 2016 |
Suko92: .
U can use any amount ofsolar panel for it in as much as u are using mppt charger controller in ur connection. Bur note if u are using more dan one panel to charge ur battery bank as it wil charge ur battery fast in due time, aw u ar going to arrange ur panel will depend on d voltage of ur battery. i.e 12v or 24v or 48v battery  some people wan burn house |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JUO(m): 6:42am On Jun 17, 2016 |
JUO: JUO: Hello friends. I hereby introduce this piece of a gadget to you. I have been testing this small but mighty machine for over 3 weeks now. The results turns out to be impressive. I have a few number of them for sale to anyone interested.
It is 30 and 40amps mppt controller with additional features of equalization of flooded batteries every 28 days and inbuilt display .
New Epsolar Epever Tracer A series available. For small setup 12-24v. . Max pv input voltage 100v. 30a only 0000k for the first buyer Features: • Advanced MPPT technology • High tracking efficiency no less than 99.5% • Peak conversion efficiency of 98% • Ultra-fast tracking speed • Accurately recognizing and tracking of multiple power point • Multi-function LCD displays system information intuitively • User programmable for battery types, load control etc. • 3-Stage charge with PWM output • Common positive grounding design • RS485 port with industrial standard MODBUS open architecture • Fully programmable function via PC software or remote meter
Electronic protections: • PV reverse polarity protection • PV short circuit protection • PV over current alarm protection • Battery overcharge protection • Battery over discharge protection • Battery reverse polarity protection • Load short circuit protection • Load overload protection • Overheating protection N.B Remote not included o8o-987-33709 |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JUO(m): 7:53pm On Jun 09, 2016 |
codeME: Hi all, please help with these questions I have a prag 24V inverter with 4 batteries, NO solar panel and charge controller yet but will come later, how do i know if my battery is charged since prag charge indicator will only work for a while and the indication will stop as if the charging is complete. so some questions 1. Can I test the batteries with multimeter while on power, actually has been doing this 2. What is the average DC volts in multi meter to know if the battery are charge when there is still a source of power (eg Generator or NEPA) and when there is no power. 3. What is the average lowest DC volts measured from multimeter when the battery is discharged 4. I noticed that most of the time, only battery 1 and 4 are seriously discharged while battery 2 and 3 remains almost the same while prag is showing that it is remaining 2 bars. Any explanation for this.
i checked online for examples of how to connect the batteries and it seems all is fine concerning battery connection. is it this stabilizer you are referring to? Please note this stabilizer has no battery selection but if you use a normal deep cycle battery, you are OK with the 20a charger. The maximum charge voltage is 29.3v. You can upload photos of your connection
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JUO(m): 3:14pm On Jun 08, 2016 |
JUO: Hello friends. I hereby introduce this piece of a gadget to you. I have been testing this small but mighty machine for over 3 weeks now. The results turns out to be impressive. I have a few number of them for sale to anyone interested.
It is 30 and 40amps mppt controller with additional features of equalization of flooded batteries every 28 days and inbuilt display .
New Epsolar Epever Tracer A series available. For small setup 12-24v. . Max pv input voltage 100v. 30a only 0000k for the first buyer Features: • Advanced MPPT technology • High tracking efficiency no less than 99.5% • Peak conversion efficiency of 98% • Ultra-fast tracking speed • Accurately recognizing and tracking of multiple power point • Multi-function LCD displays system information intuitively • User programmable for battery types, load control etc. • 3-Stage charge with PWM output • Common positive grounding design • RS485 port with industrial standard MODBUS open architecture • Fully programmable function via PC software or remote meter
Electronic protections: • PV reverse polarity protection • PV short circuit protection • PV over current alarm protection • Battery overcharge protection • Battery over discharge protection • Battery reverse polarity protection • Load short circuit protection • Load overload protection • Overheating protection
N.B Remote not included o8o-987-33709 48v also available |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JUO(m): 3:42pm On Jun 06, 2016 |
okoegualek: Good afternoon house.Please can anyone in thouse help see which of the diagrams below is correct for 12v 2*200ah parallel connection.Because i saw a video online saying i should use fig.2. CC: @Dmerciful @Kiekie @Juo @Bigrovar @co0guomo Thanks.Green for life. figure 1 & 2 are the same but figure 2 is more efficient. Figure 2 will make sure you have equal voltage at each battery during charge and discharge so use figure 2 |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JUO(m): 6:28pm On Jun 05, 2016 |
House please, who has this sukam Falcon or Falcon plus or Falcon plus plus should tell us the performance/review. Thanks
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by JUO(m): 6:18pm On Jun 05, 2016 |
xreakz: Anyone using this epsolar 45A or 60A mppt controller? Is it a good substitute for the more expensive American products like Outback or MorningStar?
Thanks super device believe me you won't regret getting one. Suitable for any kind of battery
|