Properties › Re: Construction Diary Of 8units Of 2/3brds Flat Structure By ARBO CONTRACTOR LTD by topsy23(m): 6:38pm On Aug 07, 2021 |
CongrYs boss, more big project to come |
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 11:03am On Aug 07, 2021 |
Good morning sir |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 11:02am On Aug 07, 2021 |
our9ja: I need an estimate of wire for 11 apartment. 5 rooms and palor self contain 6 …2bedroom and palor Did you get my message sir? |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 11:01am On Aug 07, 2021 |
Thank you all |
Properties › Re: Complete Package Design Drawing For Mech, Elect & Plumbing(MEP) with COREN Seal by topsy23(op): 8:50am On Aug 06, 2021 |
Happy weekend ahead |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 10:39pm On Aug 03, 2021 |
Thanks for your calls
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 9:43pm On Aug 01, 2021 |
Let's handle your project for you |
Properties › Re: Complete Package Design Drawing For Mech, Elect & Plumbing(MEP) with COREN Seal by topsy23(op): 4:07pm On Aug 01, 2021 |
Mykel51: We have concluded on WhatsApp already...we are meeting by Wednesday at Lekki... You remember ? Oh that's true |
Properties › Re: Complete Package Design Drawing For Mech, Elect & Plumbing(MEP) with COREN Seal by topsy23(op): 2:05pm On Aug 01, 2021 |
Mykel51: You handle MEP design for estate also ? Still waiting to hear from you |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 2:03pm On Aug 01, 2021 |
More pictures of completed project
|
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 1:53pm On Aug 01, 2021 |
somehow: Maybe we should start employing hausas, cotonue and Togolese boys since some Nigerians artisans have chosen to be useless. Nairabet, Bet Naija and baba Ijebu have taken over their lives. They don't want to sweat before getting money again |
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 7:14pm On Jul 31, 2021 |
Drdreluv: Good afternoon
How much is one bundle of 20mm/25mm Electrical conduit pipe cost in the market someone said 7500 per bundle how true sir For original dignity pipe 20mm 11,000 25mm 12,500 |
Properties › Re: Electrical Piping Both Surface And Conduit by topsy23(op): 10:26am On Jul 31, 2021 |
Mykel51: You carry out the MEP design and construction right ? Good morning sir |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 3:14am On Jul 31, 2021 |
Call us today
Thanks |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 10:55am On Jul 30, 2021 |
|
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 9:19am On Jul 30, 2021 |
1$. = N525. Which way Nigeria,. Everything will be affected and all price will change again |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 8:10pm On Jul 29, 2021 |
our9ja: I need an estimate of wire for 11 apartment. 5 rooms and palor self contain 6 …2bedroom and palor okay |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 8:09pm On Jul 29, 2021 |
our9ja: Ayatu4all@yahoo.com okay noted |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 10:23am On Jul 26, 2021 |
n3xt: Buying the materials won’t fix the issue. Someone still need to climb the roof to apply the sealant. Carpenter can do that for him . If possible to first enter the ceiling void and check before going to the roof to apply the sealant |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 10:00pm On Jul 25, 2021 |
We will give you the best |
Autos › Re: I Am Considering Buying This Car As My First Car. Please Advice. by topsy23(m): 9:50pm On Jul 25, 2021 |
DeBlessedOne: I finally bought the benz!!! The prophecy here was real!! I've even deleted all the other agent's numbers. Lol... May you also buy benz in Jesus name Congrats mine is coming soon |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 8:58pm On Jul 25, 2021 |
sinorte: I suppose items 7 & 10 are the prices for 100 meters. And item 8 is per meter? Yes 7 & 10 are in coil of 100m |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 8:24pm On Jul 25, 2021 |
Oflaylay: Someone said it is the surface of the nail, that they just need to apply sealant on the nail surface. How true is this please? Its possible. Get the flashband and apply it to the location |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 8:17pm On Jul 25, 2021 |
Oflaylay: How do they rectify a leaking roof after installation? Like two different places are leaking after milano installation. I have been calling the carpenter that handled the roofing, his number is not available and I need to do this asap. Please experience people in the house, what do I do? Thanks in advance. Check online for flash band you can use to seal it up |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 8:16pm On Jul 25, 2021 |
sinorte: Price and supplier suggestion is welcomed. Thank you.
1. 20AMP ceramic fuse cut-out 2. 1.5mm single core coleman (Red) 3. 1.5mm single core coleman (Black) 4. 16mm single copper coleman (40 meters) 5. 100AMP change over switch 6. 100AMP gear box/control switch 7. Pumping machine cable (1.5mm, 4 core) 8. 25mm Recline load wire (Coleman) 9. 200AMP knife change-over 10. 10mm single core coleman earth wire 1. 20AMP ceramic fuse cut-out (200AMP) 3,500 2. 1.5mm single core coleman (Red) 9,400 3. 1.5mm single core coleman (Black) 9400 4. 16mm single copper coleman (40 meters) 950/meter 5. 100AMP change over switch 50,000 (HAVEL) 6. 100AMP gear box/control switch 47000 (HAVEL) 7. Pumping machine cable (1.5mm, 4 core) 52000, 8. 25mm Recline load wire (Coleman) 1200 9. 200AMP knife change-over 4,500 10. 10mm single core coleman earth wire 62000 |
Properties › Re: Electrical Piping Both Surface And Conduit by topsy23(op): 8:05pm On Jul 25, 2021 |
Mykel51: You carry out the MEP design and construction right ? Yes sir Design and build |
Properties › Re: Complete Package Design Drawing For Mech, Elect & Plumbing(MEP) with COREN Seal by topsy23(op): 8:05pm On Jul 25, 2021 |
Mykel51: You handle MEP design for estate also ? Yes sir |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 7:26pm On Jul 25, 2021 |
Oflaylay: In meters it is 3mx3mx3m. The depth is 2.7m not up to 3m |
Properties › Re: Electrical Piping Both Surface And Conduit by topsy23(op): 7:16pm On Jul 25, 2021 |
Enyinne: A good electrician that can do it . The job is at Sangotedo. I don't know ur location.? If your company can do it , we can discuss over it We can handle it for you. You can send me the plan on whatsapp |
Properties › Re: Electrical Piping Both Surface And Conduit by topsy23(op): 4:30pm On Jul 25, 2021 |
Enyinne: Thanks . Pls do u hv a good electrician that can do this job . A flat of 3bedroom out of 4 flats. Fixing only 1 flat now to move in . Location Ajah You mean my workers |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 3:59pm On Jul 25, 2021 |
Happy Sunday and blessed week ahead |
Properties › Re: Electrical Piping Both Surface And Conduit by topsy23(op): 3:05pm On Jul 25, 2021 |
Enyinne: Sir , if i hv plan to have solar power in the house ,what should i add more to take it into consideration . Hope to hear from u .thanks That means you need to add additional small single phase distribution board like or 6ways So that 80or 90% of light will be in solar and some selected socket . 1.5mm for lighting, ceiling fan, extractor fan + external light Red. 5 Black 4 Green 2 2.5mm for socket Red 2 Black 2 1.5mm green 2 4mm for AC and water heater Red. 2 Black 2 2.5mm green 2 10mm Red 1 Black 20m 6mm 3-core for inverter 30m And let your electrician provide a by-pass for the inverter in- case the solar inverter is ready to be installed or faulty so that all the light will be working on grid/generator |