Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by johnson232: 10:45am On May 26, 2017 |
abdulwastecx:Nice... |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by joseph1013: 3:08pm On May 31, 2017 |
I have a question: How do you make provision for a staircase during the construction of the sub structure? Or perhaps a better question is to ask at what stage is provision made for a staircase and its various elements in a building construction? |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by abdulwastecx(m): 5:58pm On Jun 11, 2017 |
joseph1013: You provide for the starter bar of the stair (which also serves as the support reinforcement for stair other than cantilever and spiral stair) At the DPC level or ground floor slab level or ground floor level for stair carrying a very high load. here is a picture to help buttress my point better 1 Like
|
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by joseph1013: 8:07am On Jun 12, 2017 |
abdulwastecx:Thanks. This was helpful. Let me ask: After the concrete casting of the ground beam, how long before the removal of the formwork? |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by abdulwastecx(m): 5:36pm On Jun 12, 2017 |
joseph1013: 24hours you can remove the side |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by abdulwastecx(m): 6:39pm On Jun 12, 2017 |
formwork to the concrete fascia
|
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by abdulwastecx(m): 6:41pm On Jun 12, 2017 |
more from the concrete fascia iron work
|
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by abdulwastecx(m): 7:24pm On Jun 12, 2017 |
more updates
|
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by abdulwastecx(m): 2:49am On Jun 13, 2017 |
construction of the roofing work Here are the list of wood type and sizes. 1. 2x6 AYIN (APUNTU) wood for tie beams 2. 2 x4 AYIN (APUNTU) wood for tie beams, rafter, king post, strut and tie 3. 2x3 wood for purlin 4. 4 cartons of Chinese nail 5. 2x2 softwood for nogging Duration of work : one week |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by abdulwastecx(m): 2:55am On Jun 13, 2017 |
Pictures update
|
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by abdulwastecx(m): 2:57am On Jun 13, 2017 |
More updates
|
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by abdulwastecx(m): 2:59am On Jun 13, 2017 |
Completion of roof truss 1 Like
|
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by joseph1013: 1:46pm On Jun 14, 2017 |
abdulwastecx:What about for DPC casting and decking? |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by podosci(m): 2:17pm On Jun 14, 2017 |
joseph1013:It takes 28days for concrete to gain approx 99% of its strength in which case the concrete can convincingly carry its own weight and imposed load. it's safe to remove the formwork after 28days. Generally for concrete members, it's safe to remove the soffit (underside) after 28days while you remove the vertical sides after 24hrs. 2 Likes |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by joseph1013: 4:01pm On Jun 14, 2017 |
podosci:Thanks. How soon can blocks be laid after casting the DPC? What if you intend to do a frame structure? 1 Like |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by jossy26: 3:50am On Jun 15, 2017 |
Hi Abdul, the build is going great, please can you share the quantity of woods each you use for this build and the kingpost? kindly share where you got the wood as well. I also noticed you didnt use solignum on the wood any reason for that? |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by abdulwastecx(m): 5:02am On Jun 15, 2017 |
jossy26: Height of kingpost is 4m We bought about 500 pieces of 2 x 4 About 50 pieces of 2 x 6 About 450 pieces of 2 x 3. The 2 x 4 and 2 x 6 wood is called AYIN (APUNTU), very hardwood that don't need treatment. We applied solignum with kerosene, instead of using condemned oil. We bought the wood from Ibadan |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by jossy26: 4:20pm On Jun 15, 2017 |
abdulwastecx:God bless you sir, so you didnt use 3 by 4 |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by joseph1013: 10:42am On Jun 16, 2017 |
joseph1013: |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by joseph1013: 10:44am On Jun 16, 2017 |
What materials can be used for expansion joints in buildings? What about plywood and polystyrene? |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by abdulwastecx(m): 7:07pm On Jun 17, 2017 |
joseph1013:After 24hours 1 Like |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by abdulwastecx(m): 7:07pm On Jun 17, 2017 |
joseph1013: both can be used 1 Like |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by abdulwastecx(m): 7:09pm On Jun 17, 2017 |
Installation of stone coated roofing sheet
|
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by abdulwastecx(m): 7:15pm On Jun 17, 2017 |
More roof view
|
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by joseph1013: 4:13pm On Jun 18, 2017 |
abdulwastecx:Thanks. Talking about blocks, I noticed when I traveled to Uyo that solid blocks are preferred, whereas in other places hollow blocks are the mainstay. What's the difference and how do each affect structures? |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by joseph1013: 4:13pm On Jun 18, 2017 |
abdulwastecx:Thanks. Talking about blocks, I noticed when I traveled to Uyo that solid blocks are preferred, whereas in other places hollow blocks are the mainstay. What's the difference and how does each affect structures? |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by abdulwastecx(m): 11:28am On Jun 19, 2017 |
joseph1013: Solid block is heavier and better used for load bearing walls hollow block is lighter and better used for frame structures |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by johnson232: 11:34am On Jun 19, 2017 |
abdulwastecx:As an enigneer, which would u recommend for a bungalow, solid or hollow block? |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by abdulwastecx(m): 11:44am On Jun 19, 2017 |
johnson232: I prefer 9'' hollow blocks for my bungalow |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by johnson232: 11:48am On Jun 19, 2017 |
abdulwastecx:Nice...but in a case whereby one can't afford 9" hollow block & decide to opt for 6". Which would u recommend for a bungalow, 6"solid or hollow block? |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by abdulwastecx(m): 4:36pm On Jun 19, 2017 |
johnson232: I will go with 6'' hollow |
Re: Construction Of Fourbedroom Duplex And Two Unit Of Two Bedroom Flat @ Isheriopic by mufutau55(m): 4:54pm On Jun 19, 2017 |
johnson232: Check Abdul's message above... He knows well more than I do, of course... But what I did was to use 9" hollow for the outer external walls while I use 6" hollow for the inside partitions. Hope you can afford that. Hajji M. 1 Like |
(1) (2) (3) ... (5) (6) (7) (8) (9) (10) (11) (Reply)
Cost Of Rent Around Abuja|Co-tenant / AMAC Demolishes A Shopping Plaza With People And Goods Inside (Video) / EFCC To Jail Landlords Housing Yahoo Boys For 15 Years
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 44 |