Re: Solar Energy, A Complement To FTA by netotse(m): 7:44pm On May 30, 2016
My Ogas,

I have finally installed my panels and they've been up for a couple of weeks, I get somewhere between 4500 and 5000Kwh everyday,
I have 6 X 200W Monochrystalline panels (Vmp-37, Imp-5.35), I connected all of them in series parallel(made a mistake initially) and Max Amps I get is somewhere between 22 and 29 at peak sunlight (this is usually at 11AMish for me). I used 6mm stranded cable between the panels and controller, the distance is about 15m. I used a Xantra 60A MPPT Charge controller.

I have a couple of questions:

Would I get more current if I connect the panels in strings of 2 or 3?
The KW is usually see in the charge controller menu is low, highest ever is maybe 700W, even though current can be as high as 25A, what's the significance of this?
If I want to install a DC circuit breaker between the panels and the charge controller what size should it be?
Re: Solar Energy, A Complement To FTA by pranil(m): 8:13pm On May 30, 2016
Inverter AC's

This post on nairaland explains LG best

https://www.nairaland.com/1832210/why-lgs-gen-cool-inverter

and this video on youtube


https://www.youtube.com/watch?v=G0ueIUEojI0

prices use google or visit local shops

http://www.pricecheck.com.ng/offers/1739102/Daikin+FTXV+35AV1+1.5hp+Inverter+Split+Air+Conditioner/

It is quite expensive compared to normal one but offers upto 70 % less energy consumption and there is no kick to the gen/inveter everytime compressor starts but the loading is smooth

1 Like

Re: Solar Energy, A Complement To FTA by Barezzi(m): 8:17pm On May 30, 2016
@ Netotse: Whats the Voc of each panel?
Total must not exceed 150Vdc else you'll damage the CC.
You can connect them 3x2.
Re: Solar Energy, A Complement To FTA by bigrovar(m): 8:31pm On May 30, 2016
netotse:
My Ogas,
I have finally installed my panels and they've been up for a couple of weeks, I get somewhere between 4500 and 5000Kwh everyday,
I have 6 X 200W Monochrystalline panels (Vmp-37, Imp-5.35), I connected all of them in series and Max Amps I get is somewhere between 22 and 29 at peak sunlight (this is usually at 11AMish for me). I used 6mm stranded cable between the panels and controller, the distance is about 15m. I used a Xantra 60A MPPT Charge controller.
I have a couple of questions:
Would I get more current if I connect the panels in strings of 2 or 3?
The KW is usually see in the charge controller menu is low, highest ever is maybe 700W, even though current can be as high as 25A, what's the significance of this?
If I want to install a DC circuit breaker between the panels and the charge controller what size should it be?

That is too much series connection bro. I don't know the capacity of your controller vis a vis the voltage of your battery system. The rule of thumb is that total vmp should be about twice the size of your battery. That is the most efficient configuration. Sending about 330v to your controller is .. overworking it at best I doubt they are many controllers that can handle such. If your battery system is 48v then a 2:2:2 and if it is a 24v system then a 3:3 would be your best arrangement. If you overwhelm your controller with volts.. more than 3 times your battery volts then lots of energy would be lost to heat in the conversation to a lower dc volt.. and u will end up over whelming the cc killing it before it's time. Gurus in the house would add their advise.
Re: Solar Energy, A Complement To FTA by netotse(m): 8:38pm On May 30, 2016
bigrovar:


That is too much series connection bro. I don't know the capacity of your controller vis a vis the voltage of your battery system. The rule of thumb is that total vmp should be about twice the size of your battery. That is the most efficient configuration. Sending about 330v to your controller is .. overworking it at best I doubt they are many controllers that can handle such. If your battery system is 48v then a 2:2:2 and if it is a 24v system then a 3:3 would be your best arrangement. If you overwhelm your controller with volts.. more than 3 times your battery volts then lots of energy would be lost to heat in the conversation to a lower dc volt.. and u will end up over whelming the cc killing it before it's time. Gurus in the house would add their advise.

Barezzi:
@ Netotse: Whats the Voc of each panel?
Total must not exceed 150Vdc else you'll damage the CC.
You can connect them 3x2.

Apologies, I'll edit my post, they're connected in parallel. Voc is 45.3336
Re: Solar Energy, A Complement To FTA by netotse(m): 8:47pm On May 30, 2016
pranil:
Inverter AC's

This post on nairaland explains LG best

https://www.nairaland.com/1832210/why-lgs-gen-cool-inverter

and this video on youtube


https://www.youtube.com/watch?v=G0ueIUEojI0

prices use google or visit local shops

http://www.pricecheck.com.ng/offers/1739102/Daikin+FTXV+35AV1+1.5hp+Inverter+Split+Air+Conditioner/

It is quite expensive compared to normal one but offers upto 70 % less energy consumption and there is no kick to the gen/inveter everytime compressor starts but the loading is smooth


I have one of these and they're cool, they don't use the same refrigerant as other LG ACs and they work with a modified duty cycle so it doesn't come on and off like the other ACs.
Re: Solar Energy, A Complement To FTA by bigrovar(m): 12:50am On May 31, 2016
netotse:




Apologies, I'll edit my post, they're connected in parallel. Voc is 45.3336

Connecting all in parallel would give u a total V of 30 which is also not optimal especially the wiring 6mm u are using. U would be experiencing serious voltage loss. Doing a 3x 2 is your best config and would put losses to 3-5% between PV and cc.
Re: Solar Energy, A Complement To FTA by Pharyn(m): 8:36am On May 31, 2016
Gennextech:
WE HAVE HAD TWO CLIENTS FROM THIS FORUM WHO HAVE INSTALLED OUR GENNEX 5KVA 8V (3000W)MPPT INVERTER, ALSO NOTE THAT OUR INVERTERS ARE THE AXPERT BRAND THAT ARE FAVORITES IN AUSTRALIA AND SOUTH AFRICA

I am one of the clients.
Just rounded up the installation yesterday.
I had to taper down the AC charging current from 60A to 20A due to the current small battery bank (client would change battery bank in few months time). Adding solar is easy with up to 150V max input.

Thank you.
Re: Solar Energy, A Complement To FTA by Gennextech: 9:05am On May 31, 2016
GENNEX STOCKS THE AXPERT INVERTERS SIR
tradeplusib:
Hello everyone,

Does anyone have an idea where I can get the 3kva axpert hybrid inverter sold by solarshop fixed?

One of our units just went dead (totally blank no display). Its been a pretty good workhorse ,been on continuously for 2yrs +

Thanks
Re: Solar Energy, A Complement To FTA by Gennextech: 9:07am On May 31, 2016
Fantastic , yes the default charging current is 60amps , please ensure to read the manual and installation guide would be set up on our website soon
Pharyn:


I am one of the clients.
Just rounded up the installation yesterday.
I had to taper down the AC charging current from 60A to 20A due to the current small battery bank (client would change battery bank in few months time). Adding solar is easy with up to 150V max input.

Thank you.
Re: Solar Energy, A Complement To FTA by chris81964(m): 2:07pm On May 31, 2016
netotse:
My Ogas,

I have finally installed my panels and they've been up for a couple of weeks, I get somewhere between 4500 and 5000Kwh everyday,
I have 6 X 200W Monochrystalline panels (Vmp-37, Imp-5.35), I connected all of them in series parallel(made a mistake initially) and Max Amps I get is somewhere between 22 and 29 at peak sunlight (this is usually at 11AMish for me). I used 6mm stranded cable between the panels and controller, the distance is about 15m. I used a Xantra 60A MPPT Charge controller.

I have a couple of questions:

Would I get more current if I connect the panels in strings of 2 or 3?
The KW is usually see in the charge controller menu is low, highest ever is maybe 700W, even though current can be as high as 25A, what's the significance of this?
If I want to install a DC circuit breaker between the panels and the charge controller what size should it be?

63 A breaker is what I use. You max at 24 V should be about 50 amps. The MPPT steps down the voltage and steps up the amp. I will increase the voltage and reduce the amps. Also look behind your panels and see what the maximum serial connections for your your panels. I am sure you have exceeded them by a bit.
As someone said your cables are too thin too push that amount of amps over that distance. Increase the voltage and reduce the amps
Re: Solar Energy, A Complement To FTA by beejay28: 6:11pm On May 31, 2016
I need 250 ah battery, u can drop ur number here, I'd call u
Re: Solar Energy, A Complement To FTA by tradeplusib: 6:31pm On May 31, 2016
Gennextech:
GENNEX STOCKS THE AXPERT INVERTERS SIR

Thanks. But am looking to get this one repaired. Do you handle repairs? Its the 3kva version
Re: Solar Energy, A Complement To FTA by kiekie1(m): 6:54pm On May 31, 2016
elegungun:
I need any installer that can install solar panel in Osun state.

We look forward doing bigger business together .. Thanks and call on us anytime !
Re: Solar Energy, A Complement To FTA by kiekie1(m): 6:57pm On May 31, 2016
Must Power star light inverters
1kva-12v=72k
1.5kva-12v=82k
3kva(2000w)-12v=95,000
3kva(2000w)-24v=118,000
4kva(3000w)-24v=135,000
5kva(4000w)-24/48=155,000
6kva(5000w)-24/48= 175,000
7.5kva(6000w)-24/48=240,000

EP Solar 12/24/36/48v 60a mppt(e tracer) solar charge controller @ 135k

LUMINUOS tubular batteries 12v 220a batteries @78k (6pcs in stock)

Trojan 12v 205a USA batteries @ ...(limited quantity in stock)

With 35k , I can offer you the most important pro solar roof mounts including ;
2 qty solar mount rail "4200mm" ,
4 qty rack end clamp,
6 qty mid clamp,
6 qty L feet with rubber & special screw....

Same goes to angle positioning solar kits;
- Adjustable front leg
- Adjustable rear leg
- Rail splice kit
- Grounding lug


*AUTHORISED DEALER PRAGMATIC TECHNOLOGIES*
All our prag / cyberpower products comes with reliable warranty

*AUTHORIZED DEALER INDIAN INVERTERS / BATTERIES ... GENUS , LUMINUOS , EPSILON PRODUCTS*
All our products come with 1 year Warranty

*AUTHORIZED DEALER SOLAR SHOP LTD PRODUCTS*
All our products come with 1 year Warranty

For best affordable prices,proforma invoices valid for just 1 week, contact Smartcell Global Services,Lagos Nigeria. Simply call Sir Frankie "08135031951" for purchase,fast delivery and waybills .. Thanks !!
Re: Solar Energy, A Complement To FTA by zeestone99(m): 8:11pm On May 31, 2016
Contact us @ monz power solutions for your solar and inverter installations nationwide, we offer professional installation and services @ very affordable price.
Call us on 08117398294, or email
Info@monzpowersolutions.com for more details

I recently bought solar roof mount from gennex,he was close to installation site. His roof mount was solid. Keep it up gennex.

Re: Solar Energy, A Complement To FTA by sensisosu: 8:48pm On May 31, 2016
kiekie1:
Must Power star light inverters
1kva-12v=72k
1.5kva-12v=82k
3kva(2000w)-12v=95,000
3kva(2000w)-24v=118,000
4kva(3000w)-24v=135,000
5kva(4000w)-24/48=155,000
6kva(5000w)-24/48= 175,000
7.5kva(6000w)-24/48=240,000
EP Solar 12/24/36/48v 60a mppt(e tracer) solar charge controller @ 135k
Mercury tubular batteries 12v 220a batteries @ (out of stock)
Trojan 12v 205a USA batteries @ ...(limited quantity in stock)
With 35k , I can offer you the most important pro solar roof mounts including ;
2 qty solar mount rail "4200mm" ,
4 qty rack end clamp,
6 qty mid clamp,
6 qty L feet with rubber & special screw....
Same goes to angle positioning solar kits;
- Adjustable front leg
- Adjustable rear leg
- Rail splice kit
- Grounding lug


how much is your trojan 12v 205a batteries
Re: Solar Energy, A Complement To FTA by elegungun: 6:52am On Jun 01, 2016
kiekie1:

We look forward doing bigger business together .. Thanks and call on us anytime !
Good job kiekie . My family is enjoying uninterrupted power supply now. Kudos to you. The 3pieces of 250w solar panel n 40a mppt cc all working well. I will definitely call you soon to add more panels n batteries.

1 Like

Re: Solar Energy, A Complement To FTA by jazzman2(m): 9:37am On Jun 02, 2016
Gennextech:
SOLAR PANELS
canadian solar (rated 2nd in the world) SOLAR PANELS (255W)
68,000
BATTERIES
GEL BATTERIES 76,000
INVERTERS
1KVA/12V(600W MPPT) 91,000
2KVA/24V(600W MPPT) 102,000
2KVA/24V(1500W MPPT) 133,000
3KVA/24V(600W MPPT) 111,000
3KVA/24V(1500W MPPT) 142,000
3KVA/48V(3000W MPPT) 150,000
5KVA/48V(3000W MPPT) PAR-A 208,000
5KVA/48V(3000W MPPT) PAR-B 224,000
10KW/48V(14850W MPPT) 928,000
MC4 CONNECTORS
CC4K (2.5-6.0mm) 500
CC10K (10mm) 650
BA21 1,800
BM21 2,300
BM31 2,700
SOLAR MOUNT
SM RAILS 132" - 3.35m 8,000
SM RAILS 168" - 4.27m 10,000
SM RAILS 204" - 5.28m 12,500
SM RAILS 240" - 6.09m 14,500
end-clamp 350
Mid-clamp 350
L-foot 500
Adjustable tilt leg 5800
Grounding lug 600
Splice bar 750
Grounding clip 400
all our inverters come with inbuilt charge controller , saving cost for you, please feel free to contact for enquiries -08145463278


Hello Gennextech,

Can you please send me the specifications and operating manual for your 10KW/48V(14850W MPPT) hybrid inverter? I couldnt find these info on your website. Thanks
Re: Solar Energy, A Complement To FTA by omotech: 10:03am On Jun 02, 2016
elegungun:
Good job kiekie . My family is enjoying uninterrupted power supply now. Kudos to you. The 3pieces of 250w solar panel n 40a mppt cc all working well. I will definitely call you soon to add more panels n batteries.
@ kiekie, pls how much is that 250w solar panel?
Re: Solar Energy, A Complement To FTA by Gennextech: 2:09pm On Jun 02, 2016
ok sir please send me your email address
jazzman2:



Hello Gennextech,

Can you please send me the specifications and operating manual for your 10KW/48V(14850W MPPT) hybrid inverter? I couldnt find these info on your website. Thanks
Re: Solar Energy, A Complement To FTA by Gennextech: 2:10pm On Jun 02, 2016
Thank you
zeestone99:
Contact us @ monz power solutions for your solar and inverter installations nationwide, we offer professional installation and services @ very affordable price.
Call us on 08117398294, 08033913155 or email
Info@monzpowersolutions.com for more details

I recently bought solar roof mount from gennex,he was close to installation site. His roof mount was solid. Keep it up gennex.
Re: Solar Energy, A Complement To FTA by onyinyechika08: 2:28pm On Jun 02, 2016
Pls i want to install a solar inverter system in my home that can power 3tvs+2decoders, 1fridge or freezer , 3fans and 8 energy bulbs through the night say at least 12hrs.

What unit of inverter, batteries and solar panels will be sufficient for this set-up and cost+installation.

pardon me as i no understand all this calculations here.
Re: Solar Energy, A Complement To FTA by bily(m): 4:16pm On Jun 02, 2016
bigrovar:


I think it is just apt ......

I'm very much interested in your Solar setup, unfortunately I can't view the video you posted, it's been made private. Can you help unlock it grin

On the upgrade, what's the model of the new inverter and battery.
Re: Solar Energy, A Complement To FTA by tradeplusib: 5:11pm On Jun 02, 2016
Does anyone know where to service these AXPERT inverters please?
Re: Solar Energy, A Complement To FTA by DUNKA(m): 6:37pm On Jun 02, 2016
Gennextech:
Thank you
Please how much are the MC4 CONNECTORS?
Re: Solar Energy, A Complement To FTA by jazzman2(m): 7:01pm On Jun 02, 2016
Gennextech:
ok sir please send me your email address

You can reach me on: eexege@gmail.com

Thanks
Re: Solar Energy, A Complement To FTA by c0ogumo(m): 2:34am On Jun 03, 2016
********** SOLAR DEPOT NIGERIA ***********

Email: info@solardepotng.com Mobile: 0803 260 2629
www.solardepotng.com

Re: Solar Energy, A Complement To FTA by bigrovar(m): 2:50am On Jun 03, 2016
tradeplusib:
Does anyone know where to service these AXPERT inverters please?
zinox Ipowerplus is Axpert Inverters. Though I doubt they might want to take service of anything other than the Ipowerplus. You can try seeing with their engineers
Re: Solar Energy, A Complement To FTA by idsolar(m): 9:07am On Jun 03, 2016
onyinyechika08:
Pls i want to install a solar inverter system in my home that can power 3tvs+2decoders, 1fridge or freezer , 3fans and 8 energy bulbs through the night say at least 12hrs.

What unit of inverter, batteries and solar panels will be sufficient for this set-up and cost+installation.

pardon me as i no understand all this calculations here.

for me i wl not put d fridge/freezer on night run. rather frm 10am-2pm or thereabout. not that it is not possible to run at night o. also energy save frm 3-11w. load mgt, efficiency and cost wise. on price, quality matter. my take
Re: Solar Energy, A Complement To FTA by Pchinak: 10:39am On Jun 03, 2016
Hello guys, I must commend every contributor here for a job well done. Bravo to those who freely share their knowledge and demystify these things. I need your help with this please:

Present status:

I have 2Nos of sukam 1400VA UPS inverters, also I have 2Nos of multipower 12v/200ah deep cycle batteries, the house is presently powered by 1 of these inverters connected to these two batteries. The inverter is charged by a TEC 5.5kva gen which is run for 4hrs a day, some times PHCN also shows face. The inverter is mostly used at night and this is the normal loads.

1. 3nos of standing fans ( at least I know one of them is 30w)
2. 8 nos of 15w energy savers ( puts all off when its sleep time)
3. one laptop + five phones

Thinking of Solar:

I like what I've read so far here, so if am to go solar, I will like to stop the use of gen, hence I will need to power the freezer (150w), and a 46" LED samsung tv. If it will help me, I can power the freezer for some hours and put it off.

Question:

What will be my best way of going about achieving the solar dream if I have a ceiling of #250K?

cc Demerciful
JUO
Kiekie1
All you good guys, can't name you all one by one.

Thanks in advance.
Re: Solar Energy, A Complement To FTA by oliyeniun: 12:34pm On Jun 03, 2016
Please, can anybody help me review the Prag 2.5kva inverter or direct me to a link where i can get review or more info about the inverter. I found out that mine doesnt charge at certain input voltage, even as high as 157V and what is the importance of the 10A and 20A button behind the inverter with respect to charging current or voltage . Most times, i have to use a stabilizer before it charges..

2. the voltage reading and battery level on my CC is always different from the battery level on the Prag inverter. WHich reading should i trust most? Thanks

(1) (2) (3) ... (140) (141) (142) (143) (144) (145) (146) ... (1691) (Reply)

FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread

Viewing this topic: edobor108(m) and 2 guest(s)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 84
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.