Partition for First floor
|
..
|
twinskenny:Address for proper directions if available, |
So many people this area were fooled during the land purchase by selling during the dry season and the ignorant buyer will not come down from his or her car to greet locals and ask how far with this area with scope how the area be.. I'm currently handling some building projects here and I will tell you it doesn't worth it beautiful homes flooded because most are even built directly on same level with the road . Pls greet locals around and ask before paying or, building it saves a client that bought a special swamp around here , pouring filling with the hope of building a duplex he will loose his property or life due to collapse after the water level reduce.. |
Uu |
Cb |
.. Ongoing
|
Stairs work 90% Completed
|
Progress so far
|
Setting of block To lintel and beam level ..
|
Water level here is something else whenever they open the dam , so many beautiful duplex will be unhabitable during this period as well level rises above most Windows here, this area is low while some part are even more lower |
Filling sand About 7 Trucks used , well rolled and compacted
|
yungmin:Your form of argument comes inform of insult which is toxic, When you give a tiller job won't dey quote for the job, or any other profession because I sign out money and disburse fund makes me an accountant or can I even audit myself properly, SMH There's a motion already in the house reason you see firm using a QS to produce their BEME , There's too much of floated price when prepared by engineer which makes project cost non realistic or unfinished etc There's a move by NSE then can't remember the outcome read more on it and stay informed boss .. I come in peace boss , |
On the above discussion even though an engineer can prepare bill , I dont think it will be detailed like a quantity surveyor who specializes only on costing though most of our design software nowadays and presentation software gives the quantity and tonnage but they dont factor simple cost like transportation off cut of iron wastages etc.. Savage value of a project , when a project is profitable , we are not giving the in depth knowledge well while in school, some engineer already create a niche for themselves to cost civil works but its better we allow the Qs do their things and submit back to check if all materials are fully quoted for.. Engineer should stop trying to be Q's or Architect get them as frnds and enjoy discount https://allafrica.com › stories Nigeria: 'Beme is Illegal, Non-Existent in Other Countries' https://allafrica.com/stories/201008090934.html |
Gradual progress, This week activities shall be back filling of the foundation , Casting of DPC floor Setting of Block wall for the ground floor
|
Today setting out of the foundation and reinforcement schedule and arrangements all carried out ... Labour charges is fair here and ready to work .they tried all possible best to continue working despite the rain.. Iron Bender: My client owns the iron bender on site and he start complaining my stirrup spacing is too small, I should make use of 300 mm .. My foundation mat is so big and bigger than the two floors beside this building like wise the stirrup,
|
Hatesin:This is the lite render of the project I will request for a detail render and upload later on |
3d view
|
The plot is a full one having a corner piece edge , the client request i should pick my preferable half for the project , I settled for corner piece edge , we were face with which side to face one side is on a close road and the other on main access parking consideration and the likes we allowed a TPL , Surv, and The Arch settle this professionally among themselves (work colleagues ) I usually borrow decision and I enjoy them fighting for professional superiority in decision making.. |
Project Details We are building a 4bedroom duplex on a half plot which must have parking space and spacious master bedroom reason my client is rebuilding another home beside previous one without no parking space at all. Client priority's spacious M .bedroom and convenient parking Project Name: Spacex Home Project Team: Yomired Structures Design |
Nigeria are only use to the norm's if Nigeria also have lot of skyscraper even without effect of earthquake and wind I'm sure we will have more building collapse than China that's how to rate research.. Saying the Chinese code is nothing to write about is absolutely wrong and saying Chinese bridge in Nigeria are changed to bs code is also wrong for those build in the past .. You need to understand how the Chinese work after each building or construction is completed they put a regulation to it a residential building can never b use for church, even most Chinese bridge here they limit heavy load truck from going through by putting sign and top barricade because they use their structure only for intended purpose.. The said building the Chinese claimed its 100x stronger and stable than conventional one . Nigeria government already partner with China long ago to take final year civil engineering student on scholarship for more knowledge on the Chinese code and mode of construction, so we should be prepared someday in future all public project will be similar to Chinese own faster and strict regulations.. |
This machine are they for sale Do you have office in Nigeria or this machine already here in Nigeria |
twinskenny:Yaba soil not cool , similar tilt building plenty for iyana oworo |
Coming out clean |
Amastermovic:This vibration does it come from foot load traffic and have u try to also observe the structure when heavy vehicle pass through your site road as well .. the new guy approach is quite expensive (assumption) because I dont know how the building is scheme it may be d best using mesh and addition thickness of 50mm to the slab couple with finishes of tiles chairs table bed etc etc will reduce d vibration . What I'm just trying to say is while dragging your contractor you may likely need to drag ur designer a little because d reason you paid 4 is rest of mind .. Contractor as well should have an in house person to quickly help them check the design before they commence with construction .. check should be carry out for as built structure before you proceed , some as built work can land u in problem big one. or you should have posted this for long maybe a easy fix will be suggested . . |
Just for educational purpose only pls don't reference my view to d discussion, Well I have discussed vibration here few months , its a structural issue which the designer may have check for user of a structure are sensitive to vibration than others even though all structure vibrate but there's permissible allowance for this before u can feel it. If the person feeling this vibration is not comfortable with it the mind can never be at rest even if a structural engineer carry out all assessment and assure nothing is wrong. This will then call for some investigation by first viewing structural member how slender are they , checking the design and some construction pictures if available. Reinforcement etc Then if all this check and it conforms its now the engineer decision according to design philosophy to load the structure lightly because this one is heavily loaded except the new person prob your foundation to ascertain well .. To be cont'd |
barakah:Sorry about that the image u published does not give in depth of what could be wrong or what kind of collapse.. During this down pour do you notice wind in action? Do you have cracks on this wall before they collapse? Whenever the collapse occur does it get to the foundation part ? Do you usually repair the collapse and rebuild from there or from scratch? Where's your compound water channel to or do we have it pond at the back? Is there adjoining properties behind the 120 fence ? Describe the soil in a clearer terms? The collapse occur at a specific segment all the time or any stretch of the 120ft Show a clearer picture of the fence standing with the collapse part.. My consign is not identifying this only but your build wall also should be observe careful with this with the kind of pillar and casting on the fence.. |
Good Evening I have the following question of why!? Why the mix of foundation? Why dont u combine the pad part with strip footing for wall do u intend to keep something under the basement.. How good is the soil around there compare to Abeokuta. |
Let me set my observation Tent here, |
pidhoes:Red copy it took the person about 10days to give me my copy Ogun state |
michlins:Then its high time you train young lads and drop people with this odd mentality I believe I'm far younger than you and when I tell workers something and they complain I get them the next time i wont be happy with such person but I try to practice what I preach so they will adjust also.. Just get them fancy safety booth , there a face cap with shield inside very fancy also get them that one hype it well for them anyone that use it get additional package all na scope |