Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 5:39pm On Jul 09, 2020 |
bbally: please, does this items take care of thunderstorm lighting too or just voltage surge? because all my equipment are plugged to power guard. Did you experienced a direct hit on the house by thunder? Cos there may be need to beg Thor! |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 7:00pm On Jul 05, 2020 |
ojeysky: Why I may continue to get sunfit panels if I can find them. That is from a 2.25kw array, what else will premiums do than this 
Note that it could have gone beyond if not for BMS limitation So much more brother! The day i got 10.28A from a poly tier 1 panel rated @ 8.32A or so. I thought my clamp meter was broken. It stayed for more than 5mins. I forgot to take pictures cos i was busy checking out my clamp meter thinking its was faulty. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 12:33pm On Jul 01, 2020 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 6:43am On Jul 01, 2020*. Modified: 12:30pm On Jul 01, 2020 |
essegis: Thanks. The set up is actually 12v (24p4s) system.
I understand Ojeysky explanation from your previous answer so I will take my time to check each one by one under load. I might have to check across the individual screws as they are all set on a bussbars but even with that the faulty ones will show face.
I will let you have the answer when I'm done. Good, this is where the work dey. I hope u can disconnect them from the present 24p and reconnect them in 1p4s? If yes, you will do this 24 times! Ie each set of 4 in series. This is the best way to identify a bad cell and remove it. Just put a light load on each set up. And monitor the voltage of each cell, it is a task of patience as I've said before. You may not be able to identify the bad cells if u ve 24 in parallel. In fact, the bad ones in the parallel mix will eventually destroy the good ones. Pls, disconnect them asap! |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 11:30am On Jun 29, 2020 |
ojeysky: What he meant is that while they are all connected and under load, take your multimeter and start checking voltage of each cell(positive and negative of each cells) you should find some culprits Thank U for this. essegis: Hmmmm.
They are connected 24p. Do you want me to take them one at a time to connect in 4s and try? Cos if I connect all in parallel I don't have a 3.2v discharge ability.
Just helpe explain small abeg. Ok, let me rephrase: Your setup is 48v right? Which makes it 16s, now U have 24 of it in parallel Abi? If yes, then I think U will require a lot more patience to test this cells I will prefer U do it stage by stage, and group them by voltages while discharging each set with the same amount of load for a specific period. Kindly answer this questions up and we move forward from there. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:12am On Jun 29, 2020 |
essegis: The tower of power (coined from David Poz) is beginning to take shape.
Presently we have fully tested the 38120 cells and Nissan Leaf batteries, both without BMS for now. The 38120 were disappointing to say the least. Suspecting there might be some weak cells among them but no proper equipment to carry out the required tests yet.
The Nissan Leaf did okay for a short test but had to put it off as no way to charge it yet. The Victron charger is not yet configured for Lithium ion batteries. Seeing solar depot have the Mk3-usb connect for the configuration but the pepper is not here oo. Abeg if anybody get one wey I fit borrow just configure the charger I will return back immediately.
Make una try help a brother. You can actually do this with a voltage meter, just check the voltage of each cell(under load, and be extremely careful o!). The weak cells will show face, as there will be a large difference, up to or even more than 1v. Identify and remove them immediately. It's a task of patience! |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 7:01am On Jun 24, 2020*. Modified: 8:07am On Jun 24, 2020 |
ojeysky: Yes o, I have a rough idea of what happened to the first Board, would avoid it in future. What do you think happened to it? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 4:47am On Jun 16, 2020 |
cypha: If you use a lead acid battery to 70 % you are killing the battery fast My bros, i know, the battery will die in 8months! |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 5:09pm On Jun 15, 2020*. Modified: 6:10pm On Jun 15, 2020 |
unicmarket: Boss: exactly, I really think a lot of us will need to get our facts right before posting.
Thanks I greet you sir The two battery voltage charts say the same thing, 70% = 11.75V.... |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 5:04pm On Jun 15, 2020*. Modified: 6:24pm On Jun 15, 2020 |
unicmarket: I think you are confusing things bro,
70 % DoD simply means using up only 70% of the capacity of the battery
I believe you are talking about SOC, it’s just like the reverse. ?? Like using/consuming/taking 70ah out of 100ah rated, right? Recheck my initial post, and kindly rephrase urs. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 6:42pm On Jun 14, 2020*. Modified: 6:22pm On Jun 15, 2020 |
unicmarket: You can use this calculator to check how Long your Tubular and Deep Cycle battery should last @ 70% DoD( worst case scenario).
https://jekitech.com/battery-backup-time-calculator/ Why would you want to discharge led acid battery(be it flooded, gel, AGM, mtn etc) to 70% dod? For the record, the safest Dod for led acid is 20%, except u want to change it every 2.5yrs(for a very good brand ni o). Edit: let me rephrase this, safest level to discharge a led acid is; whatever the capacity, only use just 20% of the total capacity, for longevity. Anything above that, cycle life decrease drastically. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 3:27pm On Jun 07, 2020 |
Expertt: Good day all, please how many batteries and solar panels can power a 15kw Inverter for 12 hours assuming the total load on the Inverter is 12kw continuously for 12 hours . Note: the load consists of mainly pumps, electric motors and 1kw electric heater. Thanks You can't be putting the inverter on 80% of it's capacity for 12hr, u will kill it. And if u must, get another 15kw and parallel the two(30kw). For the battery and solar panels, seriously, I am not in the mood. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 3:20pm On Jun 07, 2020 |
Expertt: Good day all, please how many batteries and solar panels can power a 15kw Inverter for 12 hours assuming the total load on the Inverter is 12kw continuously for 12 hours . Note: the load consists of mainly pumps, electric motors and 1kw electric heater. Thanks Ol boy is load o! Are you really ready for this? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 9:22am On Jun 04, 2020 |
ojeysky: Yeah, cable was what I thought to be the only major advantage as well until I saw the figures MPP was throwing around (took some time off to read about what I will be getting with the 48v).
1.5kw of load on a 24 200AH gives about 170 mins backup time but the same load on a 48v 200AH gives over 400min(which is 200min if we are to match kWh capacity) so I get 30min extra backup time running 48v 100AH battery as against 24v 200AH Thanks for the datasheet. Kindly check the figures very well, 24v @1500 on a 200ah gives 164mins while 48v @1500va on a 100ah gave 158mins! 48v@100ah(4800whr) 24v@200ah(4800whr) Pls, let me know if I am looking at this the wrong way. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 9:18am On Jun 04, 2020 |
ojeysky: Yeah cable was what I thought to be the only major advantage as well, until I saw the figures MPP was throwing around (took some time off to read about what I will be getting with the 48v).
1.5kw of load on a 24 200AH gives about 170 mins backup time but same load on a 48v 200AH gives over 400min(which is 200min if we are to match kWh capacity) so I get 30min extra backup time running 48v 100AH battery as against 24v 200AH Thanks for the data sheet. Kindly check the figures very well, 24v @1500 on a 200ah gives 164mins while 48v @1500va on a 100ah gave 158mins! |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 11:11pm On Jun 03, 2020 |
ojeysky: Apparently it seem MPP took that part serious, they withdrew the 48v and sent me the 24v. When I insisted on 48v they claim that after further check the it won't be compatible with 3kva container though they had earlier indicated that they are compatible. I was already looking to experience 48v efficiency  Kindly note that the efficiency difference of 12v, 24v and 48v is very very minimal, not more than 1%. The advantage of 48v system is in the cable size. Less stress with cable, eg 12v 5000w, I will be dealing with nothing less than 120mm2 while at 48v 5000w, 50mm2 is very generous. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 6:42pm On May 31, 2020 |
adrusa: I tire o. I bought a smart BMS on Aliexpress and now they said I need WeChat to download the Bluetooth app. I also have serial cable but I prefer bluetooth. You can also try vbms on playstore |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 4:28pm On May 24, 2020*. Modified: 6:24pm On May 24, 2020 |
emyfine08: please what is a normal load for the 5kv and how to go about it Assuming a PF 0.8, 5kva becomes 4000w, 2000w continuous is ok, but u can get it up to 3000w for a very short time and not always. If PF is 0.7, u will have it at 3500w, so, 1750w continuous is ok. And max of 2500w for a very short period. Note: PF is Power Factor of the inverter. What is the inverter brand self? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 9:42am On May 24, 2020 |
emyfine08: Pls house I have 5kva 24v inverter.and I want to use it for a load of 3500watt how many battery and solar panels due I need to store it for it to work at least 12hrs.pls I need assistance thanks in advance Hi, so many things are wrong with ur questions/intended setup. But let me try small to correct some pre-thought ideas. 1. You can not run a 3500w load on a 5kva inverter fa! "If" d inverter is so efficient, say 0.8 PF, u will have just 4000w inverter, and if it is 0.7 PF, u will be dealing with a 3500w inverter. So, u can't run that load on it. I am of the opinion of not running an inverter more than 50% of its rated capacity in watts, not Kva. But u can do a short period with it, say 70% capacity. 2. Do you intend to run that kind of massive load continuously for 12hr! why? U will need to sell kidney, heart, liver etc to do this off the grid. 3. If you insist, then ur inverter can not handle such load continuously. Re-think what u want and we continue from there. But if u insist, let us know. Edit: thanks Mctfopt, u started well. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 7:34am On May 23, 2020 |
|
Satellite TV Technology › Re: Free To Air Satellite Tv General Thread by Oshomo12(m): 4:53pm On May 21, 2020 |
warboy3: ...68-70 That's great, thanks |
Satellite TV Technology › Re: Free To Air Satellite Tv General Thread by Oshomo12(m): 2:24pm On May 21, 2020 |
warboy3: ....U can depending 1,By removing the lnb cover that white cover it will add some Percent.2,changing the lnb depending on how old it is.3,By screwing the lnb gradual while u watch to see the development.cheers Thanks, I will try all three? What is the signal quality u have/got? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 10:38am On May 20, 2020 |
Dam5reey: You are missing the Point, An inverter is 3KV but continuous power is 2.4KW
And some brands are 3KVA and can do 3KW continuous
Same as the specs on the battery, The real usable capacity is advertised already so it's not a scam, they never told you it's 200AH or 150AH, it's simply put you can use 3.75KwH from battery 24200
Capacity is correct, you the only thing you can argue if the price is right or not, the specs is what it is. its was initially advertised @200AH but the usable capacity was not stated. but with the spec sheet now, its better. for the price range and dod, i think its a very good deal (if it can do the 3000 cycles at the rated 60a, it will be a good buy). |
Satellite TV Technology › Re: Free To Air Satellite Tv General Thread by Oshomo12(m): 10:27am On May 20, 2020 |
adubam: Mine is about 82% on 120cm dish oh, that's great! I forgot to add, I am using a 90cm dish. |
Satellite TV Technology › Re: Free To Air Satellite Tv General Thread by Oshomo12(m): 9:39pm On May 19, 2020*. Modified: 10:29am On May 20, 2020 |
warboy3: ...Well it is normal, most cases if,it want to rain though, depending on how cloudy it was it skips/breaking OR check ur lnb to see if, it getting weak ok. Okay, thanks. My highest quality for MBCs channels on Frq 12517 is 57%, I don't know if it can go higher? I ve tried a lot to improve it. Note, it's mbc on nigcomsat. EDIT: I am using 90cm dish, south-west Nig. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 7:59am On May 18, 2020 |
earthrealm: Am angry with LG after i bought their freezer 2 or 3 yrs ago, and the shit is just a glorified cooler. Been to LG shop twice under waranty repairs but still same story. Hence why am considering other makes.
Phcn is decent in my place avg of 12hrs daily, so my 4 battery inverter setup is doing quite nicely, should be 4th or 5th yr running on the fla batts. I now intend to add solar, hence why am considering an inverter fridge that i can afford to keep plugged in 247. 30w consumption of the Lg fridge is superb, would prefer samsung cos of my earlier beef with LG.
My thinking is..since the fridge would be running 247, it being frost free shudnt be an issue again. My other grouse with normal fridges is that. Like my old/current HT fridge, its not frost free but the freezer compartment can stay 2 to 3 days of no power and still be cold, however the fridge compartment would be in a sorry state and perishables therein would be in a bad state. It had a normal 130w consumption till kazeem fingered it, and its now 190w, so i cant afford to put it on inverter 247.the fridge tried though...13th yr now..developed issue in the 12th yr Haba! U wicked small o, little wonder we no dey see Nigeria used buy! Go and buy another one joor, u want to use it forever ni. |
Satellite TV Technology › Re: Free To Air Satellite Tv General Thread by Oshomo12(m): 9:41pm On May 17, 2020 |
olushaggy: It seems those channels on TP 12518H - 29500 (Our tv, Trybe, wazobia, etc. are now moved to 60.0e intelsat 33e or something. I don't think that's ku band. That's not a KU band |
Satellite TV Technology › Re: Free To Air Satellite Tv General Thread by Oshomo12(m): 9:38pm On May 17, 2020 |
adubam: The MBC on Nigcomsat are working well. Its only Televista, TVC and other stations on the same frequency that are off. Thank you, I will readjust my settings/position. I only have problem with MBC once we start to enter raining season or when I notice dark cloud cover! |
Satellite TV Technology › Re: Free To Air Satellite Tv General Thread by Oshomo12(m): 6:54pm On May 17, 2020 |
Hello house, I want to know if it's my tracking that is not strong enough or it's general. Most stations on nigcomsat (especially those with mbc freqs) skip/dont show during this period(cloud cover or if there is any sign that it want to rain). |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 9:33am On May 17, 2020 |
ojeysky: Same here, since I got a central stab and solar, at times I just wish I could turn back the clock. My freezer would have survive unfortunately I have not been able to get the same freezer.... I just love the display panel features on the cover. Looks like thermocool discontinued it I feel u on this freezer! Very sensitive to voltage fluctuations, I discovered this late in 2015(bought mine in 2012), the electronic panel at the bottom where the fan is got melted badly! Stopped working. I went to their repair center, and the engineer I met wanted to do Kareem repair(direct connection, I rejected it, and took the freezer back home). I waited for about a year to get the replacement panel. I fixed this panel outside, by the side of the freezer. And it has been working beautifully ever since then(though by d time I got the panel, I was already off NEPA completely). Not by choice, but by force.
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Oshomo12(m): 2:06pm On May 07, 2020 |
Hello house, Is there anyone/centre that can have a look at a MICROTEK inverter (1.5kva 12V)? Issue is a surge (after a loud thunder), charging of batteries works but not giving any output. I am asking for someone (He stays around Ibadan). Thanks. |
Phones › Re: How To Data From Airtel To Airtel by Oshomo12(m): 5:29pm On May 06, 2020 |
5Gnetwork: How can I share data from airtel to airtel because its gift date is seen, or I see that I can only share 200mb per day I really don't understand From the topic, down to your question/comment, kindly recast. |