Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 4:51pm On May 24, 2017
babaegun:
@Pranil

Thanks for your response. Still doing the research sha. The Outback/Fangpusun guys just want you to drop money for almost everything before you can view your device locally not to talk of online. Imagine getting a mate 3 for $400+ just to connect or WattPlot. Haba. No qualms sha. I am working on what a guy did online and am almost through. Am at the stage of integrating it with Grafana + Postgres or MySQL which uses a time series database to make lovely graphs. Don't know if somebody have achieved this on this forum before. Well, we will get there.
EMONCMS actually uses MYSQL database with PhP engine and apache webserver . The the api calls are all json . and you can qury the the Data using MQTT
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 4:05pm On May 24, 2017
Barezzi:
Thanks Pranil, very detailed response.
Incase you have not come across the DIY tesla streamer has done very good job in explaining simple terms use of fuse / breakers etc.

- for fuses see


https://www.youtube.com/watch?v=bFTK6c8iqXI&list=PLID-GiwIm8LO5FVtQgBDXfoWxuExG5yqC&index=5

His other videos are also great for D.I.Y enthusiast hwo have no professional background in electrical Engineering
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 10:38am On May 24, 2017
battleaxe:
@pranil, thanks for modifying an earlier note you wrote. Was easier to grasp afterwards.

Will the below workhuh?
You are wiring it slightly wrong Unless I am reading it incorrectly . Can you mark the MCB coil and power inputs separately .If following is not clear I will draw it time permitting in next few days and send it

MCB has total 6 terminals Say A1, A2 - Coil terminal Allows the MCB to become on when supplied with 230 V PH ( A1) and N ( A2)

Terminal L1 and L2 are NO rated to carry Nominal rated current at AC -7B duty
Terminal L3- L4 are NC rated to carry Nominal rated current at AC -7B duty

Please remember there is no Make before break so You cannot use this as changeover otherwise it might short inverter i/P and o/P for a sustained arc on inductive loads like motor

Only one of them can be used - based on your usage scenario

For your case one primary contactor will be needed on Grid side to avoid short circuit
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 10:17am On May 24, 2017
babaegun:
@Pranil

Love your Raspberry Pi setup and beautiful dashboard. Could you guide or point me to a place I can setup something similar for Fangpusun/Outback. Thanks as I await your feedback.
Unfortunately they do not have open protocol that I am aware . EMONCMS uses JSON calls on the API . Google srecah turned up nothing .

I got fed up with crappy software and shoddy practice of charging extra for remote monitoring by mainly USA based manufacturers like morningstar and extremely to shift to Chinese stuff . I have a ATS from company called powergen - Costs 73 USD only but comes with full windows software and remote monitoring. Anything close to that from established brands is upwards of 500 USD.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 10:11am On May 24, 2017
dejidotun2000:
Have you tried watchpower software. I have never been able to get it to work on both my 1kva and 3kva ipoweplus inverters.
Yes both all type of connections, Serail , USb and even connected to my remote display unit no issues . Can confirm that Zinox also uses it at many locations

Are your inverters serial ( the cable is like network cable at inverter end and DB-9 -9pin Serial )

The you will need a genuine Serial to USB converter - in My experience the prolific PL 2303 chipset works without problems .

See the link

For inverters after 2016 they are both serial and USB - Use the cable that came with inverter

https://www.amazon.com/Trendnet-TU-S9-USB-Serial-Converter/dp/B00BL697VA
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 1:49am On May 24, 2017
Barezzi:
I love your setup Pranil. If i can lay my hands on a monitoring software like that of Justin Case, I'd be sold...
I just love his dashboard.


https://www.youtube.com/watch?v=ZAwG9VtvSGE
You can do same with emoncms. see my dashboard variations - You can configure it your way in half an hour once the basic setup is running

The yellow one is for my kids and wife . They know very well based on battery charge status when to use TV or washing machine etc. The moment the pointer is in Orange they swtichoff non essential stuff such as AC , TV , etc.

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 7:14pm On May 23, 2017
Barezzi:
grin grin grin
I have used Prag , Sukam, Mpower etc at sometime of other and also familiar with Hight end units like SMA , Schinder etc.

Unless netmetering becomes legal in Nigeria it does not make sense to spend r times the money on AC coupled system with attend losss of efficiency


I am basically running the two inverters full time in DC mode with the Third inverter and solar keeping the battries topped up. via NEPA or 7.5 KVA DG .


The way it is setip is the load is divided in following priority - if one is not sufficient the next source is used to make upo the shortfall Solar , NEPA , Gen, Battery


Apart from the High end systems ( mainly german) I have not come across any budget inverters which give you power sharing options .

In the price of one Conext XW 6848 I can buy 6 to 7 units of Axpert with paralleling , remote monitoring and have cash to spare smiley

Now if NEPA becomes 65 Naira per unit and you decide to go completely offgrid with the whole house including conditioning , pumping , water heaters etc. or DISCO's allow you sell excess Solar then it is different story
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 7:02pm On May 23, 2017
All my units in one picture

Ignore the wiring mess. Installing new monitoring software on my Raspbery Pi

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 6:55pm On May 23, 2017
bigrovar:
You mean MPP solar and Voltronic are one and the same? I thought there were different companies
YES Voltronic is the OED - MPP SOLAR makes some of the units based on their design in Taiwan and gets boards for some specially the CE marked units of grid tied inverters for Europe I guess ss . For a long time I also thought MPP Solar was the OEM but then when I ordered remote display unit from MPP SOLAR ( Zinox does not sell it in Nigeria) I noticed the box it cam in carried Voltronic label - I guess they forgot to remove it
On close inspection even the PC is marked with Voltronic .

Considering the history , and product lines it is anybod'ys guess who is the actual maker .

By the way the reason MPP solar is so much mentioned on the forums is that the company has horrible support in technical. They refuse to support you without getting serial no Picture from you. Now I know whay they want to support only their own products and not solt by voltronic to other CKD unit sellers .
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 6:48pm On May 23, 2017
bigrovar:
Thanks a lot for the detailed response. Indeed that Axpert series of inverters are hugely popular in most OECD countries like Australia and South Africa. I would be considering them now so that I can join the club of cool kids with their cool wall mounted Inverters. I just wished the pure inverter units without the charge controller bits are also sold in Nigeria
Considering you get charge controller , Inverter and AC charger in one unit at the price of only Charge controller from Outback or Midnight solar it does not mater if you don't use some of the parts
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 3:13pm On May 23, 2017
[quote author=pranil post=56800640][/quote]Software by order of prefrance
ICC - http://iccsoftware.co.za/

Lucibus - http://www.lucibus.com/( end May) and OLD verison -http://www.homoandroidus.com/forum/ - Inverter control , Hostory ,s ttings Additional peripherals to switch on and off specific loads based on production /SOC and web browser interface on any phone tablet

Watchpower( official) -
https://www.youtube.com/watch?v=XO1Oskf3HHA - Download from Any vendor site also comes on CD with inverter - Msut for changing some settings

Solarmon -
https://www.youtube.com/watch?v=FiBDnjGH5Oc - GREAT dashboard buggy . Don't think it is supported anymore, can't find the download link.
Website is closed - http://www.solarmonitor.co.za/


SolarPatrol
Great program used it for quit a while, stable, USB & rs232 support, great built-in timer to turn on and off inverter -
Download Link: http://www.energialternativa.info/public...Patrol.rar


SolarMon





ACDC power monitor
never used it but seems a fair effort has gone into it.
Website : http://www.acdcpowermonitor.com/Default.aspx
Video review :
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 2:49pm On May 23, 2017
battleaxe:
Hi Pranil,
Curious as to how you sized your fuses between your batteries and inverter.

I thought with 8 nos. of 200Ah, 12V batteries, making a 48V, 400Ah battery bank, that you would need a bigger fuse?

Also, there are several schools of thought on having a fuse on the negative. I notice you have a fuse though halved. May I ask why?

@Barezzi
Max PV Array Open Circuit Voltage for the 5kVA is I think 145V DC.
Plenty of protection I am paranoid - I have 125 Amp on each battery connection - +Ve and +Ve https://www.amazon.com/Blue-Systems-MRBF-Terminal-Blocks/dp/B071H9NL9G

After that A combiner switch with 250 Amp DC fuse on +Ve and 150 Amp MCB on -Ve ( The mCB alo stops my systym from Feeding more than 8 KW in oveload cases - ) See attached photos

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 2:31pm On May 23, 2017
Barezzi:
Pranil,
1. What's the maximum PV input DC voltage - 150 V DC ( ( 37 Voc and 3 in series and 2 in series I have used both combinations without problem- 2 panels in series has a marginal better efficiency )
2. Number of mppt inputs - Nigeria models 1 input upto 3 KW ( 60 Amps) - you can get modesl with 3 seprtate inputs MC4 direct also to avoid junction box
3. The monitoring software you use? Plenty Most liked ICC from South Africa ( paid 70 USD), Lucibus Italy , Solamon , germany , Watchpower ( origanal from company) - and also Emoncms.org and PVOUT.org

Thanks Battleaxe...
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 1:09pm On May 23, 2017
Barezzi:
Egbon, there seem to be a dearth of information concerning the ipowerplus.
I have searched everywhere, nothing tangible. Even users are afraid to share their experiences... Lol
Abeg if anyone has any info, please share.
There is plenty of information just ask whatever you need . A very little known fact is these inverters ( both Ipower and Genex and other not so well known) are made by a single company called Voltronic Power - Sold in South Africa as Axepert and in Europe /Latin America as MPP solar
The company is as big as APC and very well known brand having more than 15 % global market of Hybrid inverters .


https://www.youtube.com/watch?v=YCXTHiurLbc


It has a loyal following in many countries and fan base .

Personally I am using them in parallel 5 KVA x 2 to even run 2 AC's and my washing machine without any major issues .

The failures you see in the market is because of bad installers/Design hence Ipower insists on complete system. There limitation is 60 V DC and nominal failures are in capacitors . This only happens when you use a charge controller than their own which tries to equalise batteries or the ones called battery desulphators. I learned this the hard way - This has been corrected in new models after 2015. Also there are many models looking identical depending on the importer ( they have identical models with PWM/MPPT , ac Charge capcity 50 Amp , 60 AMp or even 80 Amp).
Like all systems you should use your design tools referring to datasheet other components to build a correct system

They even now have a 1 .00 power factor inverter ( 5 KVA inverter does 5 KW load) and max 140 Amp charging ( 80 from Solar and 60 from Grid). All this in 700 USD is not possible in any inverter . The price and size is kept low by moving teh AC and DC protections outside the inverter hence the need to correctly design the system


for more info see - http://www.voltronicpower.com/

OR http://www.mppsolar.com/

Wbr

Anil


My system for info ( all main inverters are Ipower)


Self Consumption DC coupled Whole House system 10 KVA , 400 AH , 5600Wp with backup 7.5 Diesel Generator
5 KVA x 2 Voltronic ( Axexpert) in parallel- , 1 x 5 KVA Voltronic standalone as charge controller and charger with remote panel
8 x 315 Wp- Yahi Mono on Inverter 1 , 6 x 250 Wp Ritek ,on Inverter 2 , 4 x 255 Wp on Inverter 3 , 200 W x 3 on Make skye Blue MPPT
midnight solar PV junction and 8 x 200 AH 48 V Flooded lead Acid , BMV 702 , 450 AMP DC bus with 250 and 125 Amp fuses on +ve -ve and midpoint from Blue Sea systems with 200 Amp DC breaker
Powergen Self wired ATS with 7.5 KVA 3 ph Generator - starts based time of day and SOC to offset the battery load
emoncms ( work in progress) - http://emoncms.org/ghatikar & PVOUT https://pvoutput.org/list.jsp?sid=51733, Inveters montioring via ICC and Lucibus
Intel NCU PC , Ra Pi 3 , IO gear wireless USB , Current cost ,UK monitoring Total power and critical loads and logging to Measureit
Awaiting delivery - Powergen, Italy 3 PH 48 V 60 Amp Battery charger
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 12:50pm On May 23, 2017
bigrovar:
Has anyone here who uses any of the Axpert series of Inverters be it ipowerplus or Gennex been able to ascertain the idle consumption of these units?
I have four of them . Normally 35 watts running on Battery on Avrage can reach upto 65 Watt on full load .
See the datasheet
And these are actual measured values

I have been running these inverters for last 5 years without any major issues and when it comes to price point nothing in market can beat them .

Anybody who has questions on these can feel free to ask them. .

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 4:12pm On May 22, 2017
Contrary to the popular practice of using a changover cwitch between inverter and NEPA the actual use of Inverter is different than a generator.

The NEPA goes to inverter and then flows out to your loads ( The inverter senses availability of NEPA and automatically connects loads to NEPA)

In your case you have to split the DB wiring to possible inverter loads and non inevrter loads ( ask the electrictian if you cannot do it should be fsairly easy to modify the busbar or remove the looping)

So in your case all house loads upto PEAK loading of inverter ( normally double the rating of nominal check also the bypass relay rating of inverter ) can be connected to inverter . The MCB contactor coil will be fed from NEPA with a timer . The moment NEPA fails the contractors drop keeping only essential loads like light and DSTV /TC /Computer to the output of ineverter . ( identical to a large UPS for your computer) now based on your judgement you can manually bring some loads on or off based on your needs. The beauty of the contactor I suggested is it self resets the position on every changeover of NEPA no no risk of loading inverter on the next failure even if you had kept it on

For example if you leave the Air Con MCB in ON ( manual)positiontion and forget to Put it to Auto next time NEPA fails it will still switch off It has automatic returning to AUTO position on every coil energization See marked in the Blue

If you want further automation you can use 4P MCN ( 2 NO and 2 NC) NO for NEPA and NC for inverter automatically changing to inverter based on SOC or time of day

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 11:09pm On May 19, 2017
mank1234:
Nice. Do you have link for a modular 18mm DIN programmable timer too?
Even available on Konga or Jumia or local market
http:///programmable-digital-timer-switch-relay-control-220v-16a-2610886

http:///water-heater-programmable-auto-switch-timer-220v-25a-3110204
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 11:24am On May 19, 2017
mank1234:
https://m.aliexpress.com/amp/item/32810512997.html
If your question is choosing btw PHCN and inverter output with phcn priority. Use above link.

If however you want to be on solar(or inverter) at specific time, say day time and switch to PHCN after sunset consider attached image for setup.

The link for timer and contactor that can do this is as follows:
https://m.aliexpress.com/s/item/32762997458.html

https://m.aliexpress.com/s/item/32613347337.html
I prefer to USE the Single Pole MCB and contractor built in instead of one single contactor. This allows you to force individual loads or circuits to stay on NEPA or inverter if you choose or switch by timer based on your usage .e.g. weekdays keep fridge on Inverter as teh afternoon load is small when kids at school. Weekends Frdidge off but TV on inverter . Added advantage is you just replace the existing MCB no Seprate DB requited or create a DB with Rows of MCB saving space and money


https://www.aliexpress.com/item/MKWCT-25M-Manual-220V-240V-Universal-Home-Household-AC-Contactor-Modular-Modulus-25Amps-2P-2-Two/32671904971.html?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 8:06pm On May 17, 2017
bodeface:
@Dmerciful,

Thanks so much for your time and explanation, may be what I will do is that I will combine the two circuit and use only one inverter, the two banks are just redundant, they do same job. Just wanted to ensure there is always power available.

How much is your surge protectors? Please, you missed the second part of my question:
"for the combiner box must it be OEM type or can one get one locally or fabricate or is there a make shift type that could be used as I do not see so much specialty in combiner box as it looks like a small DB could be used for combining"
See The attached. Combiner Box- Local market - DC MCB - From Seller on Forum, VPD ( surge protect) from Aliexpress. total cost 20 % of Midnight solar - I have midnight solar PV Junction box also and while much easier to work and can combine three ( even 6 or 12 models available) banks this setup also works without issues for 150 V DC unearthed system . If your CC or inverter needs negative eratherd then Midnight solar is recommended ( remember to use use 25 mm2 or larger cables to link the MCBS's to avoid local heating or use a Cu busbar cut into shape .

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 5:29pm On May 02, 2017
efuro:
At least, so says the watt meter & CC readings.
Always 0.5v difference.

The ba3 are wired @ 24v series x 3 parallels. No special loop to equalise the three 12v nodes.
A 10 mm2 cable will loose 4.6 mv per amp per meter How much is the current ?. if the shunt of the meter is 200 MV then 0.2 drop is in meter itself .see attached. Meanwhile 0.5 v is 2 % difference which is well within tolerance level of measuring instruments ( normally they are class 5 ) if you want accurate readings you need class one meter like fluke Multi meter or hight quality meter ( e g. BMV 700 e) panel meter .

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 12:01am On Apr 26, 2017
bigrovar:
The sukam falcon plus 1.6 kva 24v uses 25w against the 30w advertised in the manual. Its one of the reason I love that inverter.



I use a battery monitor with watt/Amp counter. Previously used a watt meter that comes with a shunt. The device is not bidirectional hence it can only read one way. I set it up between inverter and battery to read watts inverter takes takes from the battery. To know the idle load of the inverter. All I need do is

A: Turn off the load output of the inverter and check the watt meter readings.. Since the inverter becomes the only load on the battery the watt meter gives me its idle load.

B: Put an AC killawatt meter on the inverter out and read how much load in watt is on the inverter. Compare it to how much load the inverter takes from the battery. The difference gives me the inverter self consumption load.

Now I use the victron energy watt meter which is much more sophisticated than the previous device. This one is multi directional as it shows what goes into and out of the battery. The device easily shows me the inverter without stress. The former option is much cheaper though.
Some of the better designed inverters like Prag or Ipower have a power saving mode to solve this issue They switch of the inverter mode and capacitors etc to reduce consumption. If I remember correctly Prag uses 100 Watt in normal mode and 35 watt in power saving. Every four second and so they send a pulse to check if the load is above rated value say 60 watt . It it is more they fire up the inverter . The problem with power saving mode is things like LED bulbs don't trigger it and keep on flashing

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 11:51pm On Apr 25, 2017
efuro:
In addition to ur earlier post. I know some enthusiast will take me on it but it may fall true dat some of these ba3 are over-rated for Nigerian market. 200AH ba3 may actually be 180AH or less even with SON seal or LOGO.
So to enjoy 5 days of off-grid, consider over sizing ur bank.
On d condition dat u have powerful mppt firing @ 98% conversion efficiency to maintain ur ba3 in good shape.
Like big wigs here have said few months ago. In crease the abosption time of ur FLA 2-3hrs. U may soon find out that ur ba3 will fall in line in no time at all
I have Luminous and enjoying over 30 months now still going strong . Top and equiliaze them atleast once in 3 months and dont discharge more than 50 % of rated capacity
200 AH x 50 V is 10 KWh at C20 rate ( 400 watt considering 20 % loss in inverter and cabling) you should use them max for 10 Hours at 400 watt load ( not 5 days !)anything more and you are crossing 50 % dod drastically reducing their life They are rated for 1200 Cyles for 50 % DOD and only 500 at * 80 % DOD , if you were discharging them fully expect them to last less than a year

Also little known fact is the capacity of battery reduces under heavy load a 200 Ah bank will deliver more like 170 AH for loads over C20

https://en.wikipedia.org/wiki/Peukert%27s_law

Anil
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 11:38pm On Apr 25, 2017
emmaniche:
Good evening house, I’m new into green energy. But I’ve been mandated to make a quotation for the installation of solar energy at a particular location.
My main concern is the client in concern is really interested in monitoring the solar setup over cctv and if possible controlling the setup. i.e the charging and discharge rate, watts stored, battery level, switch time from NEPA to solar.
House is this really possible as I’ve been mandated to research into this and give back a quotation for the projected to be kick started.
Thanks very much awaiting feedback from u guys. God Bless.
My suggestion is to use one of the hybrid inverters like ipower which can be monitered with software developed by user groups. e.g. see my setup . The other inverters like SMA /schinder/Voltron are all expensive to start with . That way you can control also
http://emoncms.org/ghatikar

With a software like ICC you can even change the time the inverter uses solar and not NEPA e.g. during weekdays use solar not Nepa weekend USE nepa even if solar is available ( to avoid prematurely discharging batteries)

CCTV will not give you control and too expensive to continuously monitor because of high data rate used of video feed over internet
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 7:17pm On Apr 13, 2017
2baga:
Wow just reading this makes me think are we in the same naija... surely you have a sweet setup
LED bulbs from Philips ( e27 Base) are available in Emab Plaza at 1800 NGN each for 6 or 9 w ( 40 and 60 watt equivalent) . The shop is near the gate on right side. I forgot the name.

Light output good but not same CRI as Hue but almost matches the concentration mode color
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 3:16pm On Apr 12, 2017
I am Looking for a 40 AMP 48 V DC 3 phase( 440 V) supplied battery charger Ideally should have only taper charging . Anybody has encountered one in Nigeria or direct to me to someone who can build one ? - This is to ensure the battery charger loads my generator evenly

Alternatively 3 identical chargers rated to work in parallel with 10 to 15 amps rating for 48 V DC


wbr

Anil
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 3:59pm On Apr 11, 2017
idsolar:
i wl prefer quanta
Quanta for AGM /GEL ( i am using in office) Luminous for flooded( long life) - I am using at Home
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 3:55pm On Apr 11, 2017
bigrovar:
This set a gold standard for setting up a smart and energy sustainable home. Massive congratulations and thanks for sharing.

I never knew Amazon echo would work in Nigeria (does it have to be always internet connected ) also how did you setup your 10terabyte hard drive array? Are you use a turnkey device or built one? I hope to setup a media server with 10 tera but my aim is to use disk arrays setup to raid 5 for redundancy...That's will eat lots of 2 terabyte disks and would require a server with 10 disk drive bay. Kindly share.
FYI currently use kodi (formerly xbmc ) as media center. It is the project which Plex is based. Running for over 5 years now.
ECHO works but you have to hack it for it to tell the time correctely - I have both google home and Echo and Google home is better for andoid chromecast ( media applications) Echo is good with Harmony , Hue and yeelight .and samsung hub
USE a NAS for data . personally I use Synology 2 bay 4 TB x 2 (Raid 1) . It has it's own server for plex. I also use XBMC but prefer plex as it syncs to tablet and xbox al the watched status and has better integration - ( but you have to pay a yearly subscription) XBMC is good for direct streaming
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 11:44am On Sep 18, 2016
Barezzi:
Lovely! We're getting there...

Take a look at the link below,it's a very comprehensive analysis of renewable energy in Nigeria.
Very interesting read...
https://www.giz.de/en/downloads/giz2015-en-nigerian-energy-sector.pdf
Nice to see the study on the website. I am one of the authors. Although the study is aimed at mainly grid power of solar pv
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 10:12am On Aug 08, 2016
samnaija:
guys i need your advice. i want to attach an external smart charger to my bank 48v 200ah. what my supplier brought was a rectifier. he claims telcoms use it for their batteries. (48v50amps). is this a smart charger . i dont want something to damage my bank for nothing.
200 Ah requires max 20 to 25 Amps C10 rate batteries. Anything more and you will damage the battries unless the charger can adjust current and monitor temperature .

If you are willing to order from Aliexpress I can send you link for a very good charger . or altrenatively look on this website and find a way to order http://www.meanwell.com/product/inverter/inverter01.html

I found it very difficult to locate a good charger at that capacities as normally it is integrated in inverters
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 12:30am On Aug 07, 2016
abunafiu:
interested in home automation too. any practical experience to learn from here?.

Its been a while since I discussed my personal home set up.
I recently hit 3kw pv strength. my 2 yrs old trojans still firing like new. I have switched charge controllers from morning star to FM80 and now midnite classic.
I now live off grid and hardly drain my bank below 49.5v(with load) by 6.30am when I wake up. I now switch off my 4kw mustpower(1.5 years old) inverter off when leaving home for work. once I return home ,I go tru d logged data. my batts reaches absorption usually by 1pm.
I Have personally tried following air conditioner controllers for automation and love the ambilight followed by broadlink followed by Tado - too lazy to put links but google it they are easily found.

On the lights I primary use philips hue with logitech harmony and amazon alexa works wonderfull. Personally I found zwave too much headache. My samsung smartthings is far from smart and constantly looses connectivity with my projector screen controller and it's own socket

too many variables in Zwave and not consistent echo system

I found the broadlink platform quite good specially their power socket which keeps a history of the power use and current use for any appliance. Very Good to monitor fridge and AC

http://www.aliexpress.com/item/Broadlink-SP2-EU-Smart-Home-Wireless-Remote-Control-Electrical-Smart-Plugs-Sockets-By-app-control-switch/32655943437.html


I also use the battery monitor to check on battery from bedroom - found good to be 40-60 metrs in open adn 10-20 meters through one wall http://www.aliexpress.com/item/NEW-MHF-120S-Wireless-DC-Voltmeter-Ammeter-Power-Meter-0-120V-100A-Shunt-MHF120100S/32611336909.html
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 4:34pm On Aug 05, 2016
Barezzi:
Lovely setup Pranil.
Been tinkering with my proposed setup, and finally came up with the attached.
I have no plans to sell to the grid or go fully off grid.

Supply to the 2nd essential load panel will be controlled by my battery SOC.
Have a look and lemme know your thoughts.
The setup looks enviable. Few thoughts

1. The battery is too small for 4.6 KVA load unless that is your peak load for bedroom /lights - 400 AH is hardly 10 KWH at 50 % DOD at 3 KW it is not even 3 hours of runtime in the night . I have exat seame battery size and I can run 800 watts for one whole night ( which includes 300-500 Watt of bedroom AC)

2. You might want to consider running the inverter in hybrid solar mode during daytime to maximize that 6 KWp Solar panels solar production . In that case I suggest to use changeover along with DOD cut off to keep non essential loads connected to grid if available on days when solar production is not enough otheriwse one angr better half smiley

3. You might consider reducing the solar panel size and investing that amount in energy efficiency ( long term effects will be similar) specially as NEPA bill also comes down. Solar prices will always drop for next few years and you can always add more 1.5 KW diakin or LG AC is around 200,000 NGN but can run on as low as 300-600 WATT. LED bulbs ( i found the Yellights and Philips both reliable )- The yeelights are specially good at less than 20 USD in addition allow dimming and color change from you rsmartphone - http://www.gearbest.com/smart-lighting/pp_361555.html

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 3:10pm On Aug 04, 2016
Anybody stocking Roof mount aluminium members and clamps in Abuja . I have unusual requirement and would like to see the items first before I buy


wbr

Anil