damola1:I am envious. Pls. share on how did you get them, LCL cargo, airfreight any customs issues SONCAP etc. Can your vendor supply to Abuja ?. my email is anil_ghatikar@yxxxx.com It is must to not only install BMS to balance the battries to but a DC contactor to disconnect batteries in case of overcharging/undercharging to protect your precious investment . The Lion will have no absorb curve but have to sit at charge condition till the BMS can balance the cells Are these ATL cells ( based on blue color) normally the advisable charge and discharge limits are C/2 ( 100 amps) in your case for 2000 cycles and up life cycles I would suggest something like this where you can track the battery using mobile phone - https://www.ev-power.eu/Battery-Management/BMS123-Smart/123-Smart-BMS-Complete-Set-4-cells-with-Bluetooth-4-0.html DC relay - https://www.ev-power.eu/DC-Contactors/ |
As far as I am aware Yinglee does not sell for retail market except through approved installers. Can the forum share contact details . I am looking for double sided panels since last two months ( the LG ones are 130 K each for 300 watt) and Solarworld seem to have vanished from market Yingli also has Bifacil panels and is Global leader in twincell I am looking for - http://www.yinglisolar.com/en/products/monocrystalline/panda-bifacial-60cl/ Quote from - http://www.eco-business.com/news/why-two-faced-solar-panels-are-a-bright-idea/" Yingli’s bifacial modules, known as the TwinMax series, were launched last year, and are made using the company’s special technology, known as Panda cells. These use phosphorous, rather than boron, to treat the silicon so that it can conduct electricity by up to 10 per cent more efficiently than others." |
PRAG 48 - V ( grren color) 5 KW inverter user manual Need user manual or at least battery charging Voltage selection page /table urgently where the pot positions explained. I am replacing the office batteries and cannot find the manual anywhere ! Prag seems to have stopped supplying this inverter and replaced with a Hybrid MPPT http://www.prag.cc/index.php?module=product&event=viewdetail&pid=227&cid=79 |
kiekie1:you are welcome. That was my first solar device 4 years back from 45 amps I now have 4 Charge controllers which can handel together 225 AMPS ![]() |
earthrealm:I second the addition of panels and not running fridge on batteries - The CC will never get cooked with the addition of Panels - the recent trend is to add between 1.1 to 1.5 times the rated current to cater for cloudy days In case additional harvest is generated the CC limits it's current to max rated - Only draw back is on really sunny days you are wasting the harvest Also if you run CC on the limit all the time you might shorten the life but I guess 5 years from Now you will have much bigger panels and CC based on the trend in the solar industry What is you might observe is also called clipping which is additional ripple but not serious issue unless you are using one of the sensitive european brands In my own House, I am using a Victron 150/45 amps on a solar bank of ( 2440 w- 305 x without any temperature warningBeware though except midnight classic if you exceed the VoC ( more panels in series) it is short cut to white smoke from CC ( the caps blow almost immediately ) |
earthrealm:Lead acid batteries should not be left in partial discharge for more than 24 hours to ensure long life ( the full charge cycle also included BULK ( full rated current) Absorb and then float if possible. ( Trojan Carbon is exception to this as it can handle partial SOC If the panels can barely top up the batteries over 6/8 hours then absorb cycle is missed and you will feel the reduced lifetime Which means for a typical day your batteries should at least exist bulk by 2 pm to remain on absorb for next 2-4 hours ( bulk is at C10 or C20 ) absorb currents are, much lower. Typically absorb is lower currents but at least 2- and max 5 times the bulk duration |
DUNKA:I can second the Prag solution. I have a Prag 5 KW /6.5 KVA running for 4 years now without being switched off except Xmas in office Handels the LED lights ( 1 .5 KW) laser printers, Photocopiers and one AC without any issue. My earlier SUKAM used to make loud fan noise on the same load and I chose PRAG as the FAN comes on only when boost charging. The only model I know in market which is rated at 3 times rated surge power Also, Has a power saving mode so You can throw it in Power saving when not using to allow it to charge batteries when NEPA is available without depleting batteries But it is also climbed in price now that I checked on Konga 550 K https:///prag-48v-v-series-pure-sine-wave-inverter-2787585 |
c0ogumo:WOW Lion from Simplify in Nigeria - I could not believe my eyes - Now we wait for the price to DROP. I noticed it is the only preorder. How much time to get door delivery in Abuja after ordering Also, something wrong in website coding the next page / Navigation button when clicked leads to original coding page not the rendered page Now we want to see more brands, please wbr Anil |
NiyiOmoIyunade:I am doing, in fact, the same a more advanced version 1- 5 x 2 10 KVA Ipower in parallel on battery bank for 4 AC's +Washing machine and dryer Charged with power gen 2.5 KW 3 phase charger - plus 3 KW Solar through built-in MPPT - rarely more than 2 Ac's are on but the peak capacity is designed when children or house help unknowingly will switch on W/C , dryer, and AC - The system simply switches off on Battery low voltage ( set at 49.5 V) The other set is Victron 5 KW/ 2.5 KW solar with supplying critical load, fridge plus lighting computer TV etc. - Since the bank is shared the critical loads are backed up till as the battery is never depleted below 50 % due to charger and gen combo When battery is full the Ipower inverters kick in again the gen is on AUTOstart with Victron Venus GX and self-made ATS switch control panel My research for LIon is to change Victron to its independent bank. But looks like I will have to wait till prices drop. ( no space for Lead acid) I have 3 chargers 48 V -20/ 50 Amp single phase in case somebody is interested in buying. I bought a high-efficiency charger and hence three are redundant - I am using this now The PowerGen charger - http://www.batterychargerpowergen.eu/en/prodotti-alta-frequenza/ - 90 % efficiency and available up to 200 amps In case somebody wants to buy - current price links are below - make a reasonable offer One is with pulse and battery recovery 48 V 20 Amps perfect for 200 AH - https://www.aliexpress.com/snapshot/6716059717.html Another is pure taper charging which works also as power supply - perfect for 400 AH or higher - similar to this - but 50 Amps with normal cable and UK plug was 268 USD when I bought it last year https://www.aliexpress.com/item/Lead-acid-Battery-Charger-48-Volt-10-Amp-EU-plug-with-XLR/32693316126.html The third is actually from a reputed manufacturer - mean well ( expertize in electronics is needed for this as It has control and set point pins which need to be wired) https://www.aliexpress.com/snapshot/7786307566.html |
In the interest of sharing pls. find attached my comparison of LIon batteries ( which can be leaglly imported into Nigeria) and lead acid The transport costs are approximated to the higher side. All battery prices are from manufacturers with direct quotes Conclusion - Unless NERC increases unit rates of makes net metering legal. LEAD ACID comes out winner The only exception is Smplifi USA who claim to have more than 10,000 Cycles life at rated capacity |
GeorgeD1:I considered the wind here in Abuja for my House few years back - Even got an Anemometer ( wind speed measure). I could hardly get 1-3 m/s best times of the day. if you look at wind speed versus power ratio for most of the turbines you will realize that best speeds are above 6 ms normally 10 -14 m/s At low wind speeds, the cost per KWh was working out to be outrageous Wind speeds throughout Nigeria on average are 4-8 m/s unless very near to coast or on top of hill Below is a very good site for Nigeria wind in case you are considering wind energy http://www.neenigeria.com/html/wind_energy.html |
JohnKester:Yes, I am also interested in price to compare with Trojan RE200 ( carbon ) The cycle life looks to be good on spec sheet . What are the vent caps the battery supplied with - the water saving ones ( spin top?)
|
jazzman2:Thanks, I checked from web -9 http://www.evlithium.com/CALB_Battery/42.html) They are multipurpose for EV ( vehicle) and storage with very high rating - Similar Brand new cells on EVpower are 250 USD per piece so it a good deal DAMOLA has found ![]() But additional BMS is recommended - http://gwl-power.tumblr.com/tagged/SBM they are rated as Cycle Life 80DOD% ≥2000 times Max.Charge Current ≤3CA Max.Discharge Current Constant Current ≤4CA Impulse Current ≤12CA Standard charge/discharge current0.3CA
|
JohnKester:Yes LIFePO4 does not have mneoery but cycle life and % DOD is very much related |
jazzman2:The seller has not quoted the Max charge and discharge current. The cells pre 2015 were all low rated ( mostly 50 Amps) ( 2.5 KW on 48 V max) Please check that. Also cycle life was low ( 1500-1600). Nowadays cells with 5000 cycles are available. Herwin ( china ) gave me a quotation of 1900 USD exworks of brand new for 10 KWH (48 V) including BMS and assemled system - I have also posted the freedomwon pricing earlier The used ones are coming to almost 2000 Pounds for 48 V plus you have to use cables, MCB, fuses etc. If you are looking for 24 V Soladin in Ghana is selling Lithium Ion assemblies with high current rating Charge voltage Nominal voltage 标称电压 48V 3 ominal capacity 标称容量 208Ah @0.2C Discharge(放电)最小值 210Ah @0.2C Discharge(放电)典型值 Energy 能量 10.08kWh 5 Charge current 充电电流 Standard charge(标准充电): 0.2C Approx 6 Hour(约6 小时) Rapid charge(快速充电): 0.5C Approx 1.5 Hour(约3 小时) 6 Standard Charging method 标准充电方法 0.2 CC(constant current) charge to 58.4V, then CV(constant voltage 58.4V) charge till charge current decline to 0.02C 0.2C CC (恒流) 充电至58.4V,再 CV (恒压58.4V) 充电直至充电电流 0.02C. 7 Max. charge current 最大充电电流 100A 8 Max. discharge current 最大放电电流 100A 9 Max.Pulse Current 最大脉冲电流 300A(<3S) 10 Discharge cut-off voltage 放电截止电压 40V(常规) 11 cell & Method 电芯组装方式 (3.2V30Ah) 16S7P 12 Operating temperature |
GeorgeD1:I definitely believe you . there is no doubt in mind about the advantages . In India most of the big cities the town planners have made it mandatory for new building spurring faster adoption Seriously looking at the solarshop flat plate collector as my further research showed me that it is Grundfos OEM brand made in China. I have serious respect for Grundfos as a brand . The price is a deterrent though at 600 K it is worth 25,000 Units of Nepa which the back of envelope calculations say worth heating 2000 Ltrs of water by 10 DEG |
kiekie1:@ kiekie1 Are you selling any brand currently. The ones on Solarshop say Out of stock |
bigrovar:the Venus GX ( Same as CCGX ) is here - https://github.com/victronenergy/venus/wiki/raspberrypi-install-venus-image Runs very well I ran it for few months before getting the Venus GX ( i wanted the Can bus and Tank levels) The 7 inch display for RS components is the official version with case - No driver required - http://uk.rs-online.com/web/p/graphics-display-development-kits/8997466/ Lagos dealer is below
|
pranil:any reviews for this unit - https:///protek-solar-water-heater-200l-with-heating-element-1647054 |
GeorgeD1:Problem is that my cold water is boosted at 3 Bar which means I have to boost Hot water also with a booster to match user expectation on temperature versus mixer handle position. Also, Hot water boosters /recirculation pumps are on the pricier side How much outlet temperature normally you get on a sunny day and cloudy day. I might use the hot water as preheated water for one boiler /heater used for the main bathroom and later think of adding other rooms Where did you get your system from? Any issues with the pumps controllers ? |
babaegun:My wife complains that the house should have it's own user manual ![]() I am mainly using my Pi3 to run emoncms with ICC to mintor my Axperts ( which power the AC) and same PI is also attached to Touchscreen displaying the VRM from Victron /Venus GX The another pi is only running measureit with currentcost to measure whole house consumption and uploading to PVOUT ( thats how I posted teh booster data) I am now trying to get the unified dashboard for Victron and Axpert ( ipower) and other stuff using http://freeboard.io/ Currently stuck on some code on Github which needs to be modified as I have no Knowledge of JAVA- If any inhouse experts are there I can use the help |
jazzman2: you have every right to call me out .I only pointed out the dangers both technical and legal and left the choice to consumers in the absence of any regulation on GRID Tie since the community is full of D.I>Y enthusiast who might lack the knowledge to make a suitable decision . May be it was misunderstood F.y.i. in my case is I am using a islanding relay and a Em24 Energy meter to ensure that the grid export is prevented along with PV assitant and a Venus GX If you want I can send you my discussion with Victron ,EVpower and ,d Soladin on applying Microinverter. Even Victron has not done it before and I am trying to test a solution Infact both Soladin and victron advised me against it as it has never been done before making me more curious to try it out |
Saipro:I have a Victron Bidirectional Quattro( multi) so I am planning to try using a small Grid tie Inverter with solar panels and a current sensor - See atttached PDF - The sensor can be similar to this -https://www.ev-power.eu/Measure-Test-Tools-1-1/Current-Monitoring-Relay-PRI-52-AC-0-5A-25A-CE.html#tab2 A soladin or APS grid inverter will be ideal choice ( 1 KW to 2 KW) - http://www.mastervolt.com/products/solar-inverters/soladin-1000-web/ APS- http://www.apsmicroinverter.nl/ The idea is that whenever the current sensor senses the Current flowing from PV panels to Multi or from Multi to PV panels the sensor after 1 min will switch off the Powercontactor feeding the water heater/Boiler - The contractor timer waits for 10-20 min and resets if there is no current flow then the water heater remains connected till the current sensor switches it off the idea being that in daytime the solar PV inverter will directly feed power to water heater. After midday when the heater gets thermal cutoff there is no power draw from heater the excess energy is fed back through multi to loads and battery You can set timers( time of Day) and even a bypass switch to feed the heater directly from Multi in winter or night if some top up heat is required. Alternatively, a time of the day timer can be fitted to disconnect heater in the evenings /night to prevent draw from batteries ( in case your inverter is not passing the grid to the heater) Since the grid tie inverters have efficiencies between 95-97 % you are using the full yield and compared to the DC heating element you can locate your panels anywhere and heater anywhere in the house as long as they are connected at AC side Also, the solar panels can be smaller say 500 watts ( set current control higher than the difference of Panel average yield and heating load) OR They can be much larger ( set current control or a lower value say 1 to 2 amps) In my case I am planning to use a similar setup but instead of heater use it for running an air conditioner - The one advantage I have is that the AC is inverter type. so it ramps up the load from 100 Watt to 900 watts in linear fashion giving ample time to the contractor to act and disconnect if it is a cloudy day without much tick toc effect
|
GeorgeD1:Yes but in my particular case I have 5.6 Kwp installed with house load of just 500 watt during normal school days except washing machine for one hour. Since I am in rented House it is easier for me to relocate the PV panels and Gyserwise than to rearrange plumbing. Also Gyserwise fits with my main design principle. When the grid is available to use the grid as far as possible. At current 24 NGN /Unit Grid power is still cheapest per unit of energy in Nigeria. if the situation changes we shall see The other option I was thinking of was to use PVT panels ( hybrid panels) where solar PV is combined with EV tubes Uptil now I did not find them in Nigeria market. http://www.staffordarea.saveyourenergy.org.uk/what/solar/Solar%20PVT%20hybrid%20panels http://www.eesy.uk.com/services/micro_03_PVT/index.htm https://www.alibaba.com/showroom/pvt-hybrid-solar-panel.html |
tivta:yes I am using Plex with my Synology and works without any problem Synology also has DSaudio which cats to chrome cast since this is primarily a Solar forum we can discuss offline Any more issues you can directly reach me anil_ghatikarAtyxxxx.com |
[quote author=tivta post=58575168][/quote]Choemcast Audio oand video both work. I use play store from India so Google music also works . Even if Google music could ot work there are plenty of apps which support googlecast Audio - Personally I use Deezer ( www.Deezer.com) and TuneinRadio along with Pocketcast regularly |
GeorgeD1:May times but the plumbing headaches stop me from doing so. Now the solar panels are dropping in price I am thinking of converting existing geysers into solar geyser using SolarPV- e.g. One 200 Ltr Solar water heater at 200 K + plumbing upwards is similar to 3 x 300 Watt + one Gyserwise controller - http://www.geyserrobot.co.za/Technical_Details/technical_details.html I will switch off NEPA to Gyserrobot using a Relay based on SOC. So If the SOC is high then Gyser will use the PV Just have to find time during my many projects. Currently trying to automate my projector screen to drop down on voice command from google home |
GeorgeD1:Haha . It's not complex. all those pipes and joints are left after initial machines were added removed etc. Plus I am a lazy plumber sometimes I just leave old pipes in capped instead of replacing the whole circuit It is a normal system but built with redundancies and parallel circuits so I can choose the water source and or the outlet I have a water purifier for drinking water that I built myself. to keep purifier running I need clean water intake. Also, the borehole used to cause stains on taps and especially on the car body and window glass so water softener. The booster to improve pressure as with Security cabin, BQ and gardening in parallel to house sometimes the pressure is too low to be usable except for the pumps the whole setup did not cost more than 30,000 including NRV's, valves, Floats etc but guarantees 24 Hours pure clean water with constant 3 Bar Ultimately all is done with two separate purposes pleasure in building things yourself and life hacking ( improve your life by modifying stuff around you to suit your purpose) |
Reprobate:Galaxy S7 |
Saipro:Abuja or Lagos ? |
chris81964:Very nice installation - clean looking and nicely matched battery box to Victron blue and nicely laid out with minimum battery lengths/ I had few questions though. It's not a criticism but I am trying to understand how inverters are normally used in Nigeria 1. Are you not using AC IN -2 or AC out 2 - I don't see any wires or MCB for it. 2. Why there is a changeover switch. Victron has its own built in transfer switch rated 110 Amps of much better quality 3. Is there no earthing either for body or neutral? Normally an ELCB on output and connection external earth should be provided as Victron has floating output 4. if there is no other brand charge controller than BMV was not needed. Quattro has built in SOC monitoring you could have used Venus GX/CCGX giving customer the choice to see the battery status and other parameters online through mobile or on PC/Tablet - Was the price a constraint |
Juokorow:I have three Tanks Water001.jpg ( the smallest Groudn tank 1000 Ltr receives bore hole water acrosss the day - Bore-hole runs on Solar only ) The Water is pumped to overhead tank 1500 ltrs - Again daytime solar only as the pump is controlled by float levels The overhead tank slowly discharges into 5000 Lts ground tank through a 10 Micron filter and a water softener unit - Typically 1000 to 2000 Ltrs a day depending on when I serviced the filters and how much use was there in a day The 5000 Ltr ground tank also receives direct waterboard water ( once or twice a week for an hour if I am lucky ) Water 003 .jpg - You can see the water filter ( blue cap) and water softener ( white cylinder) Water 002 jpg my abandoned water pump and booster tank ( they are still connected as backup but not powered up) Water 005 .jpg - The scala ( black machine) takes the water from 5000 Ltrs and supplies to whole house . - The overhead tank is also connected to house via a NRV and bypass switch incase the pump is bad or I am cleaning the tanks - The whole system is interconnected and interlocked with controller and floats so only manual part once is a month is cleaning the filter and restocking the softener with Salt
|
without any temperature warning