Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 12:55am On Oct 22, 2017
earthrealm:
ok confirmed what i have suspected!.
you know where i can get the VE usb cable locallyhuh
Komponents and rack or dealers in Lagos

Komponents & Solutions Rack
27B Ize-Iyamu Street Off Billingsway
Oregun, Lagos State
Mr. Adeniyi Afilayan+234 802 307 7749+234 176 403 53ren00power@aol.comhttp://www.ren4power.com
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 4:46pm On Oct 20, 2017
earthrealm:
Its fangpusun 1.16 firmware. 60amp 48v mppt cc.which is a direct victron clone.
The equalization setting is grayed out.
I hope the software is free and readily available.

For remote monitoring...what did u use to connect it to the web?.

Edit..saw thr app on playstore and the bluetooth connector on amazon too...wahala..
So just to set up equalization...i get to jump tru all these hoops..
Guess thats the price to pay for cloned stuff..
Btw epsolar and the fangpusun/victron clone....wch wud u recommend?....


Cc chris18964

https://www.amazon.com/gp/aw/d/B01CGFF8Q2/ref=mp_s_a_1_1?ie=UTF8&qid=1508429368&sr=8-1&pi=AC_SX236_SY340_FMwebp_QL65&keywords=victron+energy+bluetooth&dpPl=1&dpID=41v8zzYdJfL&ref=plSrch
Cloned or not clone the equalization is turned off on purpose in case the user is not familair with the concept

The setting becomes visible once custom voltages are selected

App is free on play /appstore -

You can always use a laptop and .Ve direct to USB cable ( cheaper )

EPsolar I have no direct experience - I have ordered one Itracer including pure inverter to experiment with Wind and solar hybrid . so Will update in December probably.

again no experience with clones but Victron absolutely yes. Much better than Morningstar for ease of use .

A little-known fact about Victron is that they manufacture it in India!

The new Victron Smart solar CC's support Bluetooth connection out of the box - https://www.victronenergy.com/solar-charge-controllers/smartsolar-150-85-150-100
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 3:25pm On Oct 19, 2017
Saipro:
I find it interesting that no one would volunteer the information. The issue of flexibility and crimping problems are real but the real reason is something quite different. Google up "skin effect", if my memory serves right.
smiley Skin effect is prominent in AC systems, not DC systems. In Ac systems For preventing electronic interference, however, stranded wire holds a disadvantage because the air channels between strands magnify the skin effect caused by magnetic fields on the surface of the wire.


If a Wire can be crimped by the hydraulic press than both stranded and non-stranded work the same. But for direct connection to terminal stranded are preferred due to higher contact area

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 3:13pm On Oct 19, 2017
ghostt:
We recently designed our mppt solar charge controller, targeting Nigerian market, our mppt comes with two year warranty, affordable and reliable, 98% efficiency, utilizing three phase Buck converters for higher current and higher efficiency.
Looks exact copy of Makeskyblue -

https://www.aliexpress.com/store/product/MakeSkyBlue-60A-MPPT-Solar-Charge-Controller-Regulator-for-12V-24V-36V-48VDC-Unbeatable-Price/1759821_32629969109.html

I have one which was in service for 6 months. Except loud fan noise worked reliably. Took it out of service when fixed the Victron Bluesolar as I wanted to minor data remotely
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 3:08pm On Oct 19, 2017
earthrealm:
Ok good.the attached doc was talking about heating n possible fire from thick strand cables.

Also on the fangpusun/Victron energy clone equalizition issue.
Bigrovar i recall u use fangpusun...can u shed more light?.
what is the model type No.

For Victron, you have to use a programme called Victron Connect Either on PC or on Ipad/Iphone or android tablet/ phones
Also to connect to the MPPT CC you need either one of these

1. Ve direct to Bluetooth dongle - http://www.ebay.co.uk/itm/Victron-Energy-VE-Direct-Bluetooth-Dongle-FREE-EU-Delivery-/301579173692
2. Ve direct to USB cable - http://www.ebay.co.uk/itm/VE-Direct-to-USB-cable-Victron-Energy-connects-to-VE-Direct-interface-/253043764801

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 3:02pm On Oct 19, 2017
earthrealm:
so any idea why small strand cables are prefferred to the thicker less strands type as shown in the picture below. dont really understand the explanation in the pic

2ndly anybody using fangpusun/victron energy mppt charge controller.
can the person confirm if it has equalization settings, from the manual its saying a software is needed to turn on the equalization setting
The explanation is right there in picture ( last Para) basically more strands to mean more copper in contact with the terminal.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 3:10pm On Oct 18, 2017
GeorgeD1:
dmerciful,
you may need a forklift or crane to lift each battery if really you're looking for 12v 2000ah. besides, it would be a very costly proposition.
smiley smiley a 2 V 2000 AH weighs 130 KGS and almost 04 meter x 0.4 metr - A 12 V will be almost 1 Ton in weight if you can find a supplier . Imagaine the shell thickness of plastic container to handle that weight

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 1:02pm On Oct 17, 2017
Konnektions146:
Anil,
the bolded above is made where, please?
Ipower / Gennex all use voltronics with rebranding ( links earlier on the forum) It is a Taiwanese company with a very good reputation in the budget market. Sold in SA as Axpert in Australia as giant power , worldwide as MPP Solar etc.

their factories are also in China but so are the iPhone factories http://www.voltronicpower.com/oCart2/index.php?route=product/product&path=24&product_id=123
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 1:11pm On Oct 16, 2017
http://punchng.com/electricity-tariff-may-increase-by-61-5-soon/

Electricity tariff may increase by 61.5% soon

Okechukwu Nnodim, Abuja

The tariff payable by electricity consumers may increase by 61.5 per cent any time soon following the latest revelation by the Nigerian Electricity Regulatory Commission on Friday that it was waiting for a final approval from the Federal Government before implementing the new rate

According to NERC, the actual tariff for one kilowatt-hour of power is meant to be N51, as against the current unit cost of N31.58 for which electricity distribution companies are selling the commodity.

NERC explained that the actual tariff of N51/KWH was arrived at based on the economic fundamentals considered when carrying out minor tariff reviews, adding that the commission had completed the process for the new tariff but had yet to receive an approval from the Federal Government to announce its implementation.

It disclosed this at a training programme in Abuja.
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 1:10pm On Oct 16, 2017
JohnKester:
Further information

The system is 48V.
The battery bank is made up of two (2) strings of 370AH each connected in parallel to give 740AH.
The PV Array is a total of 5.3KW in two strings connected to two charge controllers.

The loads are merely a description of what would be powered by the inverter, rather than what would be powered simultaneously.

Cheers
for 48 V you can have a look at Victron Quattro 5kw - 1 million or 8 KW/10 KW ( almost space price) - 1.8 million ,
SMA Sunny island - 8H - 1.6 million


Something cheaper is ipower /gennex 5 KVA ( 4 KW) x 2 = 8 KW /10 KVA approximately 6000 K including parallel kit - Can be expanded upto 24 KW single phase

I have no personal experince wityh Magnum but i think one unit is max 4.4 KW

All the inverters have chargers built in . Inverters without charger cost approximately 100 K less but it is better to buy with charger ( easier to resell or charge in emergency)

cheap alternative is china made inverters but for a such a serious system I would advise against it
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 5:13pm On Oct 14, 2017
foonshur:
thanks for the links, will definitely check them out. Battery make is Okaya.
And I'm also sorry for the confusion caused. Ba3 = Battery.
Mr Chuckdee, walahi I no be indomie generation.
smiley Okaya is Indian Brand but the website does not inspire confidence - NO datasheets or charge curves. I have sent them a message for datasheet. Let's see if they respond


https://www.okayapower.com/shop/smf/ob-200-12-2/
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 1:14am On Oct 13, 2017
foonshur:
downloaded and read the manual for the TriStar 45 and to my amazement, it was stated categorically that there are no set charging settings for the sealed maintenance free ba3s as they are "unreliable". guess we'll have to go with custom settings and please what voltages would u recommend for the bulk, absorb and float charging states.
And my question still remains, even if the cc is confused as to how to charge the ba3s effectively, is that suppose to affect how the inverter charges the ba3s too? (its a SKG inverter, 1.5kva 24volts)
I am a bit confused about ba3 . is it a type of battery or manufacturer name- A quick google search revealed only OLX ads and Nairaland. What is the make of battery? you may find the recommended settings on the manufacturer's web page
Knowing battery chemistry is important before making the settings

see this link on morningstars webpage - https://www.morningstarcorp.com/morningstar-best-practices-battery-chemistry/

another excellent source is - http://batteryuniversity.com/learn/article/charging_the_lead_acid_battery

I am doubtful if the SKG has temperature compensation or four stage adaptive charging looking at the picture.
Good settings in morningstar should keep your battery at peak performance
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 8:37pm On Oct 12, 2017
efuro:
I have not used TriStar 45 but I know it is a powerful CC and it should have GT Mode function.

I will advise u state the type of ur inverter or snap both cc & inverter so dat those with similar type can assist you with settings.
If the Tristar was started with Solar PV first before the battery was connected it might have registered wrong battery type of voltage specially with the discharged battery.

Check the dip switch settings for battery type and voltage as Auto settings sometimes get fooled
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 8:35pm On Oct 12, 2017
adewasco2k:
My setup and advise on improvement or do good maintenance?

PV array: 2 piece of 130w mono
30ah CC
250ah 12v battery - Lifepo4 battery
1kva Inverter


So far everything works great!
Are u not using a BMS with Lifepo4 is the CC and inverter capable of handling LIfepo4? Otherwise, you are reducing the life of the battery . Lifepo4 charge and discharge have to be adjusted based on battery temperature
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 8:33pm On Oct 12, 2017
zeestone99:
Call us for your neat solar and inverter installations @affordable price, we also sell renewable energy products such as inverters, battery rack, batteries, charge controller and solar panels.
You can also check out our previous installations on facebook.com/monzpowersolutions

Call 08117398294 nw for enquiries.
It looks like the electrician in the picture is using his pliers to twist two solar cables together. Correct me If I am wrong . There is nothing else with the solar installation which requires pliers.
I have long frowned on such practice. The correct way to do is use MC4 connectors and couplers with their low price there is really no excuse
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 5:19pm On Oct 11, 2017
makavele:
,,,
The amps are directly there Initial Current Not more than 30 Amp - Please note that that current is also for battries at 25 DEG C> if hotter the current should be reduced ( most of the advanced inverters and charge controller do temperature compensation )


Quote directly from Victron AGM datasheet -
During the bulk phase the current is kept at a constant and often high level, even after the gassing voltage (14,34V
for a 12V battery) has been exceeded. This can lead to excessive gas pressure in the battery. Some gas will escape
through the safety valves, reducing service life

15. Charge current
The charge current should preferably not exceed 0,2C (20A for a 100Ah battery).The temperature of a battery will increase by
more than 10°C if the charge current exceeds 0,2C. Therefore temperature compensation is required if the charge current
exceeds 0,2C.

https://www.victronenergy.com/upload/documents/Datasheet-GEL-and-AGM-Batteries-EN.pdf

You can try to lookup your battery supplier datasheet to check correct values
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 1:20pm On Oct 10, 2017
efuro:
Nice Pictures, also elementarily kool for a beginner. Enjoy ur freedom 247.



Need not to worry, the CC will handle amps going into the battery. My fear is ur consumption/backup time. angry angry
The batteries like to be charged C10 (max .13C) normally ( so for 100 AH it is 12 amps only). The battery will get killed faster due to high temperatures during charging. better add one more battery in parallel at the earliest
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 1:16pm On Oct 08, 2017
GeorgeD1:
barrezi,
cost is only a tiny fraction of what comes into play when going for renewable energy.
let me flip the question the other way round: what is the cost of staying in darkness?
i guess the answer is zero naira? so if cost is our only consideration we might as well
decide to save the huge amount we have invested so far and remain in darkness while
waiting for the elusive phcn to supply us power whenever they deem fit. however, will
that be a good option? no?
so here comes the fuel guzzling, noisy generator to fill in the
gap for those long hours almighty phcn decides to keep us in darkness. and this is where
it gets really interesting: if mr idsolar had been running his generator for this length of
time (august till date) commensurate with the up-time of his charge controller, he
certainly would have spent enough money on fuel to buy his solar system all over again.
I agree. I may only one of the few who is praying for cost of NEPA to go up so more people see the light and invest in solar ( not as a replacement of generator but something which makes commercial sense)

A diesel generator on average will cost 60 NGN/KWh considering diesel at 200 NGN/ltr. This is independent of diesel. Small diesels in the rage of 5 to 40 KVA will cots on top of that approximately 30 to 50 NGN /KWH depending on the load factor.
Considering with 3 KWH /KW of solar panel on average it takes 3-4 years before your investment starts making the profit . With correctly sized lithium this period dramatically reduces to 2 years a or less due to efficiency of Lithium
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 4:42pm On Sep 27, 2017
efuro:
Am giving pv-dc-electric heating a thought. (CC load dump diverson) or Just 2 dedicated PVs, 12v DC heating element, but still wondering/planning how to work around heating tank. I may do hybrid to AC disabled ariston tank.

At the end, I may end up spending just a quarter of the price of tube solar heater.
angry

Still weighing DIY options angry
Different readymade solutions on the market you can find more

https://www.geyserwise.com/products/pv-water-heating-systems/150l-pv-water-heating-system/

https://www.aliexpress.com/item/3000W-Excess-plus-Solar-I-boost-Alternative-Energy-saving-for-water-boiler-infrared-heating-system/32613200769.html?
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 4:08pm On Sep 26, 2017
efuro:
huh huh

https://www.youtube.com/watch?v=M1YFqBl6Cxs

undecided undecided


https://www.youtube.com/watch?v=iyGmFWMQHHs
Yes, I am doing that on top of Solar direct heating. I just ordered last week 360 W x 2 Canadian solar meant for heating - Using Victron Quattro and microgrid inverter. The cheap heating element of 300 watts will also be inserted in solar heater tank


But the biggest advnatge of direct solatr water heating is it is not so senstive to direction of teh tubes as the round tubes make efficient use of sunlight . The pV panels have to be orieneted right .

In my case the Northwest side was free and sees enough sunlight for water heating but not for PV production
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 3:46pm On Sep 25, 2017
dsunmade:
Saw an earlier post by JUO of his BMV data. I am wondering why the discharged energy is about half of the charged energy? Is it peculiar to flooded batteries? Should one expect better ratios with lithium batteries?
YES, Lead acid charge efficiencies are between 65 to 85 % . If your numbers are lower means one of the two things

1. You batteries dont drain enough which means most of the time the charging pattern is short boost mode followed by longer absorb mode - Absorb mode efficiency of Lead-acid is very low as most of the energy is lost in heat

2. Batteries are old - The charger is running prolonged in absorb mode


for comparison, my 40-month-old lead acid normally cycled to 20 to 30 % DOD with occasional deep discharge when the generator decides to misbehave - efficiency is close to 70 %


and NO lithiums have efficiencies of 90 to 96 % !!! one main reason I am shifting to them . and also can be charged at higher rates means my generator does not have to run for more than an hour

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 3:32pm On Sep 25, 2017
GeorgeD1:
hello pranil,
for those with protek solar water heater products like myself,
it comes with an assistant tank which does exactly the same job
so really no need to buy additional accessories to control water supply
pressure.

notice the assistant tank on top of the system in the first picture.
Thanks . It does the same thing of pressure reduction. Unfortunately, protek insisted that I buy the pressurized solar system at more than 500 K for ground mounting making me drop the idea earlier

Now i will purpose this system with pressure control on inlet, booster on outlet and connect to my existing 50 lts Ariston so effectively having 120 lts+ 50 lts hot water storage with full redundancy. On cloudy days IO just switch on my storage heater
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 3:40pm On Sep 24, 2017
pranil:
Solar Water users? and gurus in the house

How did you connect the inlet of the tank ( cold water )?
Direct to Overhead tank, to the borehole, manually fill using a tap

The reason I am asking is I came across this https://www.aliexpress.com/item/Automatic-water-control-valve-solar-water-heater-feeder-assistant-tank/1935638063.html

there is a single and double pipeline model


In my solar heater user manual ( Simba make 120 L - looks like made in China) the manual recommends all filling methods which are manual and the tank has overfill discharge outlet which means if I connect to water source the water will flow out from discharge outlet.

I also believe the tank and tubes can take max 0.7 bar operating pressure. In addition, the water when heated expands 3 to 5 % which means it needs space to go


The system I came across only fills at 0.5 bar and the overfill outlet has to be connected to the 2-foot pipe above water level. I believe the water coulm works as counter pressure stopping inlet water.

I intend to drain the tank from top outlet using a small 300 watt booster to match my house pressure of 2.5 bar
user manual

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 3:20pm On Sep 24, 2017
Solar Water users? and gurus in the house

How did you connect the inlet of the tank ( cold water )?
Direct to Overhead tank, to the borehole, manually fill using a tap

The reason I am asking is I came across this https://www.aliexpress.com/item/Automatic-water-control-valve-solar-water-heater-feeder-assistant-tank/1935638063.html

there is a single and double pipeline model


In my solar heater user manual ( Simba make 120 L - looks like made in China) the manual recommends all filling methods which are manual and the tank has overfill discharge outlet which means if I connect to water source the water will flow out from discharge outlet.

I also believe the tank and tubes can take max 0.7 bar operating pressure. In addition, the water when heated expands 3 to 5 % which means it needs space to go


The system I came across only fills at 0.5 bar and the overfill outlet has to be connected to the 2-foot pipe above water level. I believe the water coulm works as counter pressure stopping inlet water.

I intend to drain the tank from top outlet using a small 300 watt booster to match my house pressure of 2.5 bar

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 3:10pm On Sep 24, 2017
Very good idea
the charge rates are same most of the time as discharge currents but I will add the column for the max charge current
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 2:56pm On Sep 22, 2017
hisenjos:
You are welcome.

Do you have more details of the 10kwh battery you want to get? Does it have a bms?

I would be interested in a group buy with you if you are willing.

See my contact on my signature.
see my earlier group buy post 2 weeks back on freedomwon and comparison prices of all lithum battries which are accesible in Nigeria

updated file attached
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 12:44pm On Sep 21, 2017
hisenjos:
@damola1
@pranil

Would recommend a programmable solar controller with enough panels and charge only on solar as much as possible.

Good source of info for lifepo4

https://www.solarpaneltalk.com/forum/off-grid-solar/batteries-energy-storage/lithium-ion/15966-simplified-lifepo4-charging-and-care
Thank you great article.

But solar is not an option for office batteries for me.

At home, I have a Victron Bluesolar 45 amps with 2.5 KWp Yachi panels from Kike1 so no issues there
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 5:51pm On Sep 20, 2017
Hurray PRAG 5KW inverter supports LiFEPo4 batteries !!!!!!

I found the PRAG manual and what I suspected was right - The Prag has built in support for Lithium .

So now I can use a battery with Cheap BMS - I found a reputable 10 KWH 48 V with 2000 Cycles battery at 3000 USD . now only to sort ouut the shipping smiley


p.s. Can the house shed some light if the new Prag hybrid ( charger/inverter/MPPT) also support LfePo4 - Can be imporant when you want your investment to be futureproof

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 5:43pm On Sep 20, 2017
Doable but not advisable for couple of reasons

1. Multiple points of failure - 3 electronic units instead of one
2. efficiency losses- The inverter even if idling will consume some power while the charger and convert will have atleast 10 % losses each - not so important as total losses are equivalent to 100 Watt bulb compared to convenience but still to keep in mind
3. The charger may not be able to sense correct battery voltage due to drops across the chain so over longer run the battery will remain undercharged unless you can change the charger setpoint voltages ( or it has voltage sense to directly measure battery volatge )

Unless you are creating a total isolated supply for critical equipment such as server or NAS it is fraught with problems and may be more costly ( cabling, fuses etc) than a single inverter /charger combo


I am running a similar setup where charging is with 48 V 50 Amp - 3phase charger but the same 400 AH 48 V battery is connected to a small 350 VA inverter to power my computer and NAS essentially isolating them from Grid - ONE giant UPS smiley

Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 12:12pm On Sep 20, 2017
damola1:
Used sea.

I made a huge mistake buying 12, the seller offered 16. but it'll be corrected. for now, what's important is to test that these are what they say they are.

Can't I get this BMS and DC contactor locally?

Also, how many units of each do I buy now? no ebay or amazon links?

What I really want to know now is: How long will 8 batteries last him if fully charge. of course, am aware that's dependent on the load. my current 200ah wet batteries serve me: 3hours after fully charge using the same 4kva magnum. We have electricity up to 15hours presently daily. I want to know whether more batteries is the way to go, or solar backup to charge them. I intend to buy 28units more of these are as impressive as everyone seems excited about. 24units for a larger office we recently just got or even more. and 4units for the balance. I will let the floor know then if someone is keen on buying.
Serach for BMS 8S 28 V and your current rating . there are plenty on eBay . All vary in feature and price starting as low as 20 USD to few hundred usd

The one I suggested is slightly different in sense that It can be used for any volts from 6 to 500 and any current rating buy buying additional boards at few usd each per battery, in addition, it is compatible with Victron and SMA using enable to charge and disable discharge contacts and has Bluetooth to check battery status on mobile
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m): 12:05pm On Sep 20, 2017
damola1:
Used sea.

I made a huge mistake buying 12, the seller offered 16. but it'll be corrected. for now, what's important is to test that these are what they say they are.

Can't I get this BMS and DC contactor locally?

Also, how many units of each do I buy now? no ebay or amazon links?

What I really want to know now is: How long will 8 batteries last him if fully charge. of course, am aware that's dependent on the load. my current 200ah wet batteries serve me: 3hours after fully charge using the same 4kva magnum. We have electricity up to 15hours presently daily. I want to know whether more batteries is the way to go, or solar backup to charge them. I intend to buy 28units more of these are as impressive as everyone seems excited about. 24units for a larger office we recently just got or even more. and 4units for the balance. I will let the floor know then if someone is keen on buying.
200 AH x 26 V= 5.2 KWH approx assuming 80 % DOD= 4.16 KWH = at 4 KW load 1 hour, 2 KW 2 hour etc.


Always solar first as far as possible - Cost of energy using Solar pv is approximately 50 Naira per unit while using Lion batteries is 80 to 100 NGN per unit

Always remember Batteries only store energy which means you have to use generator or NEPA to charge them ( in absence of SOLAR PV) which means using only batteries for power supply is cost of energy ( Gen 60 NGN /unit or Nepa min 22 NGN/Unit) + battery energy cost *1.1 efficiency loss in batteries + inverter)

so for NEPA it is min 120 NGN or using gen 160 NGN versus pure solar during day at 50 NGN

I suggest SOLAR PV during the day and battery only for night and cloudy days
Satellite TV TechnologyRe: Solar Energy, A Complement To FTA by pranil(m):
pranil:
I am envious. cry

Pls. share on how did you get them, LCL cargo, airfreight any customs issues SONCAP etc.

Can your vendor supply to Abuja ?. my email is anil_ghatikar@yxxxx.com

It is must to not only install BMS to balance the battries to but a DC contactor to disconnect batteries in case of overcharging/undercharging to protect your precious investment . The Lion will have no absorb curve but have to sit at charge condition till the BMS can balance the cells

Are these ATL cells ( based on blue color) normally the advisable charge and discharge limits are C/2 ( 100 amps) in your case for 2000 cycles and up life cycles

I would suggest something like this where you can track the battery using mobile phone - https://www.ev-power.eu/Battery-Management/BMS123-Smart/123-Smart-BMS-Complete-Set-4-cells-with-Bluetooth-4-0.html

DC relay - https://www.ev-power.eu/DC-Contactors/

I am happy to buy the remaining four from you since you will need only 8 for 24 volts .



Please send me an email. then I can order bms and other accessories such as connecting links, terminal covers etc. for LIon batteries.

Also very important to separately charge each battery before putting into the bank as they are never shipped with full charge. or alternatively, allow them to balance over several hours before loading


Below is the full list I made earlier when I was designing separate bank with individual components ( 48 Volts so for 24 quantities are half)

WB-LYP260AHA LiFeYPO4 (3.2V/260Ah – 16 NO
Terminal conn. For LYP260AHA (( includes 5 spares))- 35 No.
BMS123 Smart -Complete Set (4 cells) 200 amp CT 1 NO.
BMS123 - Cell Module – 12 No.s

Charger 3.6V/20A for LiFePO4 cells (1 cell) 1 NO.
DC Power Contactor 400A, Coil 48V – 1 NO.
Power DC Fuse MEGA, 175A, M8 1No.