Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 8:26am On Dec 13, 2019 |
KIDfurniture: Someone guide me on best wire for electrical . Then I need a good pop man Coleman, Nigerchin, Kabelmetal, Purechem etc |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 10:46am On Dec 12, 2019 |
Call us today.... |
Properties › Re: The Anambra Modern Duplex Construction by topsy23(m): 10:13am On Dec 12, 2019 |
Weldone boss. Love the 3-D |
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 4:44pm On Dec 11, 2019 |
Call us today |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 10:40am On Dec 11, 2019 |
opebiboy: I am about wiring my house and the cost I got from the electricians brought so far is indeed alarming. the total number coil of wire given to me for a 5 bedroom is up to 17 coils and someone told me it shouldn't be more than 12 coils. The different wires are 2.5mm, 1.5mm and 10 mm. So experts in the house what is the rough estimate. The house is 60 feet by 30. Thanks I don't think the quantity is much if AC and water heaters is to be installed |
Properties › Re: Importance Of Proper Earthing And Bonding System In Electrical Installation by topsy23(op): 1:00pm On Dec 10, 2019 |
Call us today for your earthing system and lightning arrestor |
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 11:39am On Dec 10, 2019 |
Check out our DB's termination
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 11:35am On Dec 10, 2019 |
Recent DB termination. You will always get the best from us
|
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 9:51am On Dec 10, 2019 |
Call us today |
Properties › Re: Complete Package Design Drawing For Mech, Elect & Plumbing(MEP) with COREN Seal by topsy23(op): 10:54am On Dec 09, 2019 |
Nice week ahead
Don't forget we are here to serve you |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 4:52pm On Dec 08, 2019 |
Thanks for your calls |
Properties › Re: Complete Package Design Drawing For Mech, Elect & Plumbing(MEP) with COREN Seal by topsy23(op): 7:19am On Dec 08, 2019 |
Dennis3D: How much do you do MEP Designs it varies.. Let's see the size of the the building |
Properties › Re: Construction Of 4 Bedroom Duplex + 2 Flats In Lagos by topsy23(m): 9:55pm On Dec 07, 2019 |
Oga mi long time ooo.. where have you been |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 9:51pm On Dec 07, 2019 |
|
Properties › Re: Complete Package Design Drawing For Mech, Elect & Plumbing(MEP) with COREN Seal by topsy23(op): 11:38am On Dec 07, 2019 |
Happy weekend |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 12:35pm On Dec 06, 2019 |
westliverenterp: Can half plot of land accommodates 2 units of two bedroom flats. Yes |
Business To Business › Re: Introduce Your Business to all over world free of cost by topsy23(m): 12:13pm On Dec 06, 2019 |
|
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 12:12pm On Dec 06, 2019 |
|
Properties › Re: Current Prices Of Building Materials In Nigeria by topsy23(m): 12:11pm On Dec 06, 2019 |
|
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 8:40am On Dec 06, 2019 |
Daboomb: Well done Sir!
Thanks for sharing your calculation.
There are a few things l will please want you to take not of:
In your calculation, what you used are what we call 'absolute values" in that they are the maximum limit of power the house can draw if all appliances are IN USE and drawing Maximum Power concurrently but a few things are going to be obvious: 1.) A ll the 4A.c's wont be on at the same time. 2.) Even if they are, they wont all the on and the Cooker, Water heater all still on concurrently. 3.) Even if all those are on, all the 13 Amps Socket wont be in use at the same time 4.) Sockets are rated for the maximum power that theycan carry but we all know that when we dont plug any appliance into a socket, NO POWER is drawn from it, which means its power consumption at that point, from the Load wire, is ZERO! So, most time, only a few Sockets are in use and drawing power from the load wire. Others are idle. 5.) Some appliance like TV's, Laptops, Sound System, will draw less than 35W, yet each on is plugged to individual Socket! 6.) All 35 Bulbs in the house wont be on at the same time, some might be low-energy LED Bulbs that draw only 5W of energy so, they all will draw a fraction of what your figures gave!
So, if you look at it, IN REALITY, at any given time, REAL POWER being drawn from the 10mm load wire is less that 45% of the total POSSIBLE Power Consumption of the House, that will pass through the Load wire, at the same time, for a single pahse wiring.. Same reason Engineers use the 16mm as load wire, for single phase.
I have never see any house where appliances like Boiling Kettle is plugged to all their 15Amps Socket, and Appliances are in all the 13A sockets all at the same time, with AC and Water Heater balrring and food cooking on the Cooker, e.t.c ....all at the same time. 
This is why l and some will agree that a 10mm load wire, (and from experience), is adequate for the load of that the poster suggested. All the same, l thank you for your effort and opinion. Respect. Yes you are right but from my calculations i have diversify lighting and socket to reduce the total load |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 6:19am On Dec 06, 2019 |
nugadel: Please how good is N.W.C. Denki wire and cable for house wiring? My electrician rates it above Coleman. NWC is good but can't compare it with Coleman, Nigerchin and Kabelmetal Denki wire and cable saw it once but I don't think it's the class with what I lusted above.. |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 9:13am On Dec 05, 2019 |
Daboomb: Baba, l did not instruct you o! Who l be? I just made a humble request ni o. 
Your post does not contain the calculation, though it has the Results or Conclusion.
I am of the Opinion that the person with that Bungalow will not need a three phase connection for his Bungalow, (the only advantage is that you can switch phases when one phase lacks power and others have power, the cost lies in more than doubling your wiring needs and switching accesories).
Until we see your calculation, it will be difficult to agree or disagree with it. When l have the time, l will dig up something similar that calculates the gauge of Wire, based on the overall load. I know l have it somewhere in the past.
Also, quantity of wire required will largely depend on the span and shape of the building and wiring type (Conduit, Surface, Structured cabling). That is why l would advice everyone to buy enough wire but keep vigilance on how it is use so that "wires dont start flying over the fence" 9as my friend said) and then request for more wires start coming in.  See the attached calculations
|
Properties › Re: Complete Package Design Drawing For Mech, Elect & Plumbing(MEP) with COREN Seal by topsy23(op): 8:06pm On Dec 03, 2019 |
Let us us give you a detail MEP design drawings for your project. |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 8:05pm On Dec 03, 2019*. Modified: 4:52pm On Dec 08, 2019 |
Do your normal load calculation before you select your load cable.. I can do it for you
Call us today for your original cables |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 8:02pm On Dec 03, 2019 |
Daboomb: It is very unfortunate, that the spambot is banning it! 
Can you do us the favour by posting is as an attachment in PDF or just snap the pages and aspictures and attach it to oyur post, so as to avoid the spambot? That would be nice to see.`
I am aware that one can calculate load for each appliance (VA in Kilowatts) and use that to calculate the thickness of wire required to carry the current equivalent to such load, within appreciable tolerance) but l just dont want to go into such details with the poster but rather gave a "general, rule of thumb" advice that will still work. see the attached as instructed
|
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 8:00pm On Dec 03, 2019 |
this
|
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 9:32am On Dec 03, 2019 |
Daboomb: I understand you but your worries are unfounded ..and l will explain. 10mm will conviniently do all those things you mentioned. I use all those things you mentioned, have a large family and because l also have an alternative source of Power, my electricity is always-on, 24/7. And my internal wiring is also 10mm.
The key to the Power Scalability you are concerned about, is to wire your building such that heavy-duty equipments dont share the same line of wore. For example, l wont join the terminal/socket box of my Electric Boiling Kettle, Iron and Microwave (even though thi sone is used intermitently) or Electric Rice Cooker on the same line of wire. Each of these items will take their power on separate wire, directly from the Distribution Box (DB). This method also have the davantage that when their is a fault, only that particular item's socket is tripped on the DB.
As long as you dont cut corners, (use original wires, do proper, direct wiring for heavy equipments and let an experienced professional do your wiring, get separate DB for each flat and run a direct (from Pole) 16mm Service Wire for each flat), 10MM wire is adequate for your internal wiring. There is a calculation i have posted here that u need to follow. But just that anytime i posted it the message would be deleted and also ban for 24hrs. I would have love to share it to everyone |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 9:29am On Dec 03, 2019 |
tikristinimi21: Good evening everyone. Below is an estimate given for a 3 bedroom bungalow. 3 AC. No water heater
I want expert in the house to help counsel on the appropriateness of price and quantity.
Thank you.
cc twinskenny topsy The quantity is much and price is also high For standard 3bedroom flat below is the list cables require 1.5mm for lighting Red 4 Black 3 2.5mm for socket and water heater Red 3 Black 3 1.5mm green 3 4mm for AC Red 1 Black 1 2.5mm green 1 |
|