Properties › Re: Complete Package Design Drawing For Mech, Elect & Plumbing(MEP) with COREN Seal by topsy23(op): 4:36pm On Sep 24, 2015
Our recent electrical design: Lighting and Power layout

Properties › Re: CONTACT US FOR YOUR ELECTRICAL AND PLUMBING INSTALLATION WORK!!! by topsy23(op): 10:42am On Sep 24, 2015
Barka de sallah to all our Muslim brothers and sisters in the house.....
Properties › Re: Importance Of Proper Earthing And Bonding System In Electrical Installation by topsy23(op): 7:24pm On Sep 23, 2015
Call us today......
Autos › Re: Registered 2008 Toyota Corolla Bought Brand New. by topsy23(m): 2:42pm On Sep 23, 2015
CAN WE SEE THE PICTURE PLS
Properties › Re: The Professional Touch To Building Design, Construction And Real Estate by topsy23(m): 12:53pm On Sep 22, 2015
Weldone boss,

For your Electrical, plumbing design drawing and installation. Contact us

For further info call 08033643191 or 08051750560
Whatsap: 08033643191
Pin: 24ED26C9
Email: atope23@live.co.uk, topselg.engineering@gmail.com


You can visit our thread:
https://www.nairaland.com/1804476/complete-package-design-drawing-electrical

https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9
Properties › Re: Complete Package Design Drawing For Mech, Elect & Plumbing(MEP) with COREN Seal by topsy23(op): 5:37pm On Sep 21, 2015
adanny01:
Thanks so much on the socket color coding. I will definitely do that.

My main concern is that the inverter is a small one and will not be used on fridge and freezer but I want them both on stabilizer. There are now 3 isolations. First is does on direct, second is those on stabilizer and thirdly those on inverter and on stabilizer.
I believe 10kva stabilizer should be able to carry those appliances
Properties › Re: Cost Of Electrical Cables by topsy23(m):
marumaru:
Thanks
COLEMAN
1.5mm 3640
2.5mm. 5875
4mm. 9215
6mm. 13,455
10mm. 23,675

Kabelmetal
1.5mm 3880
2.5mm. 6300
4mm. 9,850
6mm. 14,810
10mm. 23,810

Nigerchin
Kabelmetal
1.5mm 4002
2.5mm. 6,520
4mm. 10,300
6mm. 15,280
10mm. 26,110

For further info call 08033643191 or 08051750560
Whatsap: 08033643191
Pin: 24ED26C9
Email; atope23@live.co.uk, topselg.engineering@gmail.com


You can visit our thread:
https://www.nairaland.com/1804476/complete-package-design-drawing-electrical

https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9

That's it.
Properties › Re: Complete Package Design Drawing For Mech, Elect & Plumbing(MEP) with COREN Seal by topsy23(op): 3:30pm On Sep 21, 2015
adanny01:
I saw your neat job pictures.

I have a project up north to finish soon. Am planning the finishing. I was wondering how to provide for a small inverter of about 2.5kva which will power selected power outlets, lights and fan. Am a civil engr so am playing with ideas only.

My idea is to simply introduce a 1phase DB beside the main 3phase DB. By so doing, all points to be on inverter are placed in the 1 phase DB while the rest go to the 3 phase DB. However, one phase will be used directly from the meter unit to the inverter while two other phases go to the main DB. Where it gets complicated is that I plan a 10kva wall mount voltage stabilizer which I want the inverter and other points that will not be on inverter to be passed through.

My problems is trying to prevent some crazy people from plugging pressing iron, water kettle or other heavy stuff that will kill the stabilizer. I will also limit powered sockets and some light points on inverter for power saving. Eg. fridge, freezer, inverter, 1 AC, all lights, all fans, 2tv points, water dispenser will be on stabilizer while half lights, all fans, 2 TV points will be on the inverter.

Should I alternatively use 3 one phase DB's to eliminate the confusion?
The best way is to have one separate single phase DB for the inverter, all the selected power outlet, fans, lights, fridge, freezer and TV to be power to be connected to it. Installing 3 single phase DB for inverter is a waste of money. Limit inverter socket in the kitchen to 2(one fridge and one freezer).

You can use different colour of socket outlet for inverter to differentiate them from the normal socket so that there would be no confusion.

10kva stabilizer will carry those appliances you mentioned above but it will be waste of money having 3 distribution boards at home.
Properties › Re: CONTACT US FOR YOUR ELECTRICAL AND PLUMBING INSTALLATION WORK!!! by topsy23(op): 5:24pm On Sep 20, 2015
Call us today. Happy sunday to you
Properties › Re: Contact Us For Your Electrical/mechanical(plumbing) Design And Installation by topsy23(op): 2:02pm On Sep 19, 2015
Happy weekend!
Properties › Re: Current Prices Of Building Materials In Nigeria by topsy23(m): 9:45am On Sep 19, 2015
topsy23:
For your Electrical, plumbing design drawing and installation. Contact us

For further info call 08033643191 or 08051750560
Whatsap: 08033643191
Pin: 24ED26C9
Email; atope23@live.co.uk, topselg.engineering@gmail.com


You can visit our thread:
https://www.nairaland.com/1804476/complete-package-design-drawing-electrical

https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 8:48am On Sep 19, 2015
peaceland:
Thanks sir for the response,
however I must confess I am still a bit unclear here.
1. for the little property we are working on, is that 1 or 3 phase?
2. how do you physically differentiate a 3 phase from 1 phase meter?
3. since only 1 line/phase/cutout can be working at a time, why will consumption/power cost on 3 phase be higher than 1 phase meter.
Thanks sir
If I can calculate the total load of your building I will know if the meter to be install is single phase or 3-phase.

Very easy to differentiate single phase and 3phase meter. Single phase meter has 2 connection terminal which is LIVE and NEUTRAL and 3-phase has 4 connections terminal which is RED, YELLOW, BLUE and NEUTRAL.

If you are using 3-phase supply u must use all the four cut-out, which means all the 3-phase line must goint into your ditribution board through a 3-phase changeover switch. That is why the charges on 3-phase is more higher than single phse meter. But for a single phase connection only 2-cut-out must be use at a time and you can easily change to other line when there is fault or low voltage in one line.

Thanks
Properties › Re: CONTACT US FOR YOUR ELECTRICAL AND PLUMBING INSTALLATION WORK!!! by topsy23(op): 5:53pm On Sep 18, 2015
Thank God its friday
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 7:59am On Sep 18, 2015
peaceland:
sir
a 3 phase db will use a 3 phase meter i believe?
It depends boss, it can use single phase meter or single phase meter. Single phase can be converted to 3-phase with the help of looping either from the cut-out or changeover switch but if you have 3-phase equipment or appliance in the house this method is not advisable, the appliance or equipment will not work.

And again if the total load of your house is more than 60A it is advisable you go for 3-phase meter so that u can split the the total load into 3-wires

Sorry for getting back late

Thanks
Properties › Re: Current Prices Of Building Materials In Nigeria by topsy23(m): 4:34pm On Sep 17, 2015
For your Electrical, plumbing design drawing and installation. Contact us

For further info call 08033643191 or 08051750560
Whatsap: 08033643191
Pin: 24ED26C9
Email; atope23@live.co.uk, topselg.engineering@gmail.com


You can visit our thread:
https://www.nairaland.com/1804476/complete-package-design-drawing-electrical

https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9
Properties › Re: Semi-detached Duplex At Royal Garden Estate, Lekki By MOORE by topsy23(m):
Weldone boss
Properties › Re: Construction of 4 Bedroom Duplex +3 bedroom Bungalow At Ajah by topsy23(m): 3:53pm On Sep 17, 2015
JibrilJunior:
Thanks a lot.
You are welcome boss. Let them do the plumbing before plastering so that there will be no need of breaking the walls after plastering.
Properties › Re: Importance Of Proper Earthing And Bonding System In Electrical Installation by topsy23(op): 1:48pm On Sep 17, 2015
Call us today and I have a great day.......
Properties › Re: Construction of 4 Bedroom Duplex +3 bedroom Bungalow At Ajah by topsy23(m): 7:16am On Sep 17, 2015
JibrilJunior:
A 3 -bedroom bungalow. I mean when to start putting all the pipes from wc, bath and sink to soak away.
Plumbing should be done before plastering for conduit but after plastering if you are running the pipe surface.

Thanks
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 5:59pm On Sep 16, 2015
mank1234:
What's the size of the wire taking power into the the distribution board (ie colored red yellow blue)
Size of cable(wire) depend on the total load of the building. Total load normally depend on numbers of AC, water heater. Since you are using 3-phase distribution boards it means the cable is going to be 4-core I.e red, yellow, blue and black but a separate cable for the earth.

We have the cables in different sizes:
6mm 4-core pvc
10mm 4-core pvc
16mm 4-core pvc
25mm 4-core pvc
Etc........
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 6:44pm On Sep 15, 2015
Lovely socket

Properties › Re: Construction Of A 5bedroom Duplex + 2 Flats by topsy23(m): 5:42pm On Sep 13, 2015
airsaylongcon:
A while as in? How many days?
I believe after a week you should be ready to start your block work
Properties › Re: CONTACT US FOR YOUR ELECTRICAL AND PLUMBING INSTALLATION WORK!!! by topsy23(op): 5:26pm On Sep 13, 2015
Call us today for your Electrical and mechanical works
Properties › Re: Construction Of 4 Bedroom Duplex In Benin by topsy23(m): 8:27am On Sep 13, 2015
Congrats my brother. May the Lord bless your union
Properties › Re: CONTACT US FOR YOUR ELECTRICAL AND PLUMBING INSTALLATION WORK!!! by topsy23(op): 5:21pm On Sep 12, 2015
Happy weekend
Properties › Re: Building A Solar-powered Hostel - A Learning Experience by topsy23(m): 3:24pm On Sep 11, 2015
EgunMogaji:
We use 240 volts here too but my house will be 110 volts wink

Nigeria is not as unique as you think.
Am not saying Nigeria is unique but we should be proud of father land grin. It means the output of your generator will be 110V as well. All the electronics must be 110V AC supply. But in future and things change for best for our dear country and you want to connect to public supply, u need to pull out all the cables and re-run another cables because 110V cables might not withstand 220V supply voltage
Properties › Re: Building A Solar-powered Hostel - A Learning Experience by topsy23(m): 3:00pm On Sep 11, 2015
EgunMogaji:
It's okay. I've never met any American builder that will recommend or use Nigerian cable grin

I sometimes wonder how a house built with concrete burns so robustly in Nigeria.

I'll be bringing in lots of materials from the U.S. because it's a quality that I know.

Not saying Nigerian cables are not good but......
Boss remember that US voltage is 110V and their cable is is designed for 110V 60Hz. Here in Nigeria is 220V, 50Hz
Properties › Re: Building A Solar-powered Hostel - A Learning Experience by topsy23(m): 1:59pm On Sep 11, 2015
EgunMogaji:
Not on my project wink

I'm using different cables that are more efficient and with solar power in mind. Most of what you wrote doesn't apply to this project.

There's s loss when you use standard cables.

Thanks.
Nigeria cable is one of the best cable. Most of nigerian consultant don't specify imported cables.
Properties › Re: Building A Solar-powered Hostel - A Learning Experience by topsy23(m): 9:19am On Sep 11, 2015
EgunMogaji:
Just as an aside, I'm self designing the electricals in my house to be all solar powered from the get go. Cables will be solar specific as I'm using low voltage wiring for lights and such. I will have a room full of batteries and a small generator to supplement solar charging.

By calculations and research, though I would love to control all from one source but I think there will be several stand alone units. Example the driveway gate will have it's own standalone battery and charging system, the wholehouse fan will have it's own.

To really save watts I will have sensors in each room to auto shut off if no movement detected.

I have a coworker that is earning money from Southern California Edison (our version of NEPA) monthly by suppyling electricity back into the grid. He has all the electricity he needs and the left overs goes into the grid. Who cool is that? He won't tell me his setup cost and that tells me it's probably lofty.

All this being said, I may just go with the flow and just hitch up with NEPA. There's something about Nigeria that makes me tired and unproductive.
Sir, the cable will still be normal wiring cables for all the lights, sockets, AC and water heater. The only thing solar or inverter does is to convert DC(DIRECT CURRENT) to AC(ALTERNATIING CURRENT). The outpout voltage of inverter or solar is still going to be 220V-240V, 50Hz. The battery/ies does the major workby discharging when there is no power, inverter equipment is just to convert DC to AC, turning the battery's DC power into AC at a frequency of 50–60 hertz. In our elementary physics in secondary school, we learnt how to convert DC generator to AC and AC generator to DC generator by replacing the armature coil. Solar is just for charging batteries and same work PHCN/generator does. All the big UPS equipment have something that will convert the DC to AC when there is no power supply to the equipment.

Thanks
Properties › Re: CONTACT US FOR YOUR ELECTRICAL AND PLUMBING INSTALLATION WORK!!! by topsy23(op): 6:53pm On Sep 09, 2015
larrymoore111:
pls where is ur location....thanks?
Lagos
Properties › Re: CONTACT US FOR YOUR ELECTRICAL AND PLUMBING INSTALLATION WORK!!! by topsy23(op): 8:27pm On Sep 07, 2015
peaceland:
@ topsy23,
can we talk a little about plumbing (its part of your thread title grin)
How is testing done for pipes already laid to ensure no leakage before tiles are laid?
what are the likely requirements and likely cost implications for a simple 4 bedroom structure wink
Thanks sir
Boss, there is an equipment called testing bucket. This what we normally use to pressure the all the water supply pipes both hot and cold line to be sure there is no leakage. The gauge is normmally be on 10bar when pressure testing. Find below the picture of testing bucket and the gauge. We normally put the pipes on testing for 24hrs while the gauge is on 10bar. If the gauge drops from 10bar it means there is a leakage somewhere.

Thanks

Properties › Re: (PICS) Budget P.O.P Ceiling, Interior Decoration, Plasterboard And Many More... by topsy23(m): 7:32am On Sep 07, 2015
Dominionng:
cc Topsy23
It can be change when the lamps dies. Very easY to maintain if it is direct light(I mean 220V supply). There are some spotlight that have transformer(choke), those ones are 12v supply.

1 2 3 4 5 6 7 8 ... 170 171 172 173 174 175 176 177 178 (of 212 pages)