Topsy23's Posts
Nairaland Forum › Topsy23's Profile › Topsy23's Posts
1 2 3 4 5 6 7 8 ... 169 170 171 172 173 174 175 176 177 (of 212 pages)
Call us today and get the best of our service. |
For your Electrical, plumbing design drawing and installation. Contact us Good job boss. For further info call 08033643191 or 08051750560 Whatsap: 08033643191 Pin: 24ED26C9 Email; atope23@live.co.uk, topselg.engineering@gmail.com You can visit our thread: https://www.nairaland.com/1804476/complete-package-design-drawing-electrical https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9 |
Thank God it friday |
Weldone boss For your Electrical, plumbing design drawing and installation. Contact us For further info call 08033643191 or 08051750560 Whatsap: 08033643191 Pin: 24ED26C9 Email; atope23@live.co.uk, topselg.engineering@gmail.com You can visit our thread: https://www.nairaland.com/1804476/complete-package-design-drawing-electrical https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9 |
Call us today....... |
Weldone boss , I have done a project in the estate before. More power to your muscle don't forget us anywayI have work with segcymoore, kkonsult. Still looking forward for the day I will work with you. For your Electrical, plumbing design drawing and installation. Contact us For further info call 08033643191 or 08051750560 Whatsap: 08033643191 Pin: 24ED26C9 Email; atope23@live.co.uk, topselg.engineering@gmail.com You can visit our thread: https://www.nairaland.com/1804476/complete-package-design-drawing-electrical https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9 |
Those pictures are nice installations. This is galvanise surface conduit installations. It was when I was on 6month industrial training. After my 400level I involvde in this type of project when I was on 6month Industrial training after my 400level in the university. It was done for one of the well known company in one of their factory and the warehouse. We can handle that if you give us the opportunity. The building must be well and properly earthed because of the expose galvanise pipes. They conduct easily. Thanks |
EgunMogaji:Sir, you can see from the pictures I uploaded before the way our pipes is being bent. We don't use wrench in bending electrical pipes. The pipe is pvc and it can be bend easily with the use of bending spring. A methodology statement is what you need. To know how surface electrical conduit can done. . BENDING SPRING: We have 20mm and 25mm bending spring for bending 20mm abd 25mm pipe respectively. COUPLER: for joining two pipes together(we have 20mm and 25mm) MALE BUSH: use at point entry of knockout boxes either plastic or galvanise. SADDLE CLIP: for holding(clipping) pipes firm to the wall or slab
|
EgunMogaji:Quality and neat job is our priority, all our switches and socket are well plumed. We maintained the same spacing between two sockets or switches. We use water level when we have problem with the floor level on site to get the same height of our switches and sockets and to have uniformity in our switch and socket level |
More pix
|
Sir find below the pictures as requested
|
EgunMogaji:Our recent jobs are all conduit system of wiring. We can do surface as well. |
segcymoor:Sorry boss. I was at lekki so I had flat battery. My glo line is always availble. 08051750560 |
!! |
For Electrical Design And Installation that meet IEE standard and Maintenance: -Preparation of bill of Engineering Evaluation and Measurement also known as BOQ -Conduit system of wiring -Surface Wiring -Trunking system of wiring -Change-over panel -Electrical panel -Isolators -Cables Electrical wiring accessories e.g switches and sockets of any type etc PLUMBING -Water closet, wash hand basin, Installation of tanks, Water treatment plant, borehole For further info call 08033643191 or 08051750560 Whatsapp: 08033643191 Email; atope23@live.co.uk or atope23@yahoo.com Pin: 24ED26C9 You can visit our thread: https://www.nairaland.com/1804476/complete-package-design-drawing-electrical https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9 |
Happy sunday |
Happy weekend |
Call us today |
topsy23: |
mank1234:Okay boss. A trained ENGINEER ![]() Thanks |
Happy independence nigerian |
mank1234:Boss, there is what we called load calculations during the design stage. Total load(in Amps) normally determine the size of cable to be used for a particular project. There is a table from the manufacturer for that. I have kabelmetal and Nigerchin brochure. I don't choose load cable or supply cable anyhow. I followed the normal process in choosing cable For example if the total of a particular building is 45A and you are using single phase connection, the size of cable should be bigger than the size of cable when using 3-phase connection. In 3-phase connection, all the loads will be distributed between the 3-wires(RYB). Thanks |
Call us today........ |
bizzle2:Yea we are on same page now |
Weldone boss. Keep up the good work. Can't wait to handle one of your sit electrical installation. |
Happy sunday |
ironheart:Thank u sir |
bizzle2:I mean the incoming suplly cable(Live and Neatral which is single phase) can be converter to 3-phase by looping the live through the main breaker(MCCB). Three phase line must not be connected together. It is very dangerous to do that. It must be totally avoided. |
Nice work, more more power to strength. For your Electrical design drawing and installation. Contact us For further info call 08033643191 or 08051750560 Whatsap: 08033643191 Pin: 24ED26C9 Email; atope23@live.co.uk, topselg.engineering@gmail.com You can visit our thread: https://www.nairaland.com/1804476/complete-package-design-drawing-electrical https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9 |
mank1234:Yes 16mm2 cable is okay. |