Topsy23's Posts
Nairaland Forum › Topsy23's Profile › Topsy23's Posts
1 2 3 4 5 6 7 8 ... 171 172 173 174 175 176 177 178 179 (of 212 pages)
We base in lagos but we can work in any part of the country. Our Contact 08033643191 or 08051750560 Whatsapp: 08033643191 Pin: 24ED26C9 Email; atope23@live.co.uk, topselg.engineering@gmail.com You can visit our thread: https://www.nairaland.com/1804476/complete-package-design-drawing-electrical https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9 |
3-gang
|
1-gang 2-way, 2gang 2-way and 20A DP switch for water heater
|
This is 13A single and DSTV outlet
|
This is 2-gang 2-way switch. Sorry for late posting
|
vanimashaun:Cool and lovely design. Nice one keep it up |
Good work bro |
Optionalx:What kind of electrical materials? Is it pipes, cables or light fittings? For further info call 08033643191 or 08051750560 Whatsap: 08033643191 Pin: 24ED26C9 Email; atope23@live.co.uk, topselg.engineering@gmail.com You can visit our thread: https://www.nairaland.com/1804476/complete-package-design-drawing-electrical https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9 |
! |
I hope this info is true..... |
Good job; following......... |
bizzle2:Thanks boss.....quality and neat job is our priority.
|
Nice day ahead |
For electrical and mechanical(plumbing) design and installation. Contact us. or further info call 08033643191 or 08051750560 Whatsap: 08033643191 Pin: 24ED26C9 Email; atope23@live.co.uk, topselg.engineering@gmail.com You can visit our thread: https://www.nairaland.com/1804476/complete-package-design-drawing-electrical https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9 |
Call us today |
Call us today...... Happy weekend ahead |
peaceland:Thanks for the questions. 20A DP switch is for AC and water heater, 15A is for equipment with 15A plug like some deep freezer, microwave oven etc... 16A is also a switch, it depends on each manufacturer the rating giving to their switches. Different between single(1) phase and 3phase is that single phase has 2 wires(RED and NEUTRAL). While 3-phase has 4wires(3-lives and one neutral cables). When the total current of a building exceeds 63A it is advisable to use 3-phase supply(4wires) from PHCN pole. But for a normal 3-bedroom flat single phase supply should be okay except if they have equipment that needs 3-phase supply. 4/5-bedroom duplex should have 3-phase supply. The total current will definitely exceed 63A(after calculating the total power in the building). This total power normally determine the size of generator, the size of changeover, size of gear switch and also the size of supply cables to be use. When the power supply on the 3-phase is not complete, some part of the house will not have supply. All the equipment/light/socket/AC connected to phase that is not having supply won't have power You will pay more when you use 3-phase meter. We have different types of supply cable; ARMOURED cable: this is copper cable with double insulation but very expensive and it it best cable. This cable normally pass through underground from pole to the building. Normally comes in different cores(2-core, 3-cores, 4-cores) depends on the type of installation you have. Reclin cable: this is an aluminium cable with light insulation, black in colour not expensive like armoured cable, this type of cables normally fly in the air from pole to the building. XLPE Cable: For transformer installation. It it very expensive also. |
peaceland:1-gang' refers to number of switches on the plate '1Way' means it is just on/off '2way' means there is the ability to have another switch connected to the same light, as in staircase, like the provision we have on your project. You will notice that we have made provision for a switch at the bed side which means u can switch off/on the bedroom light when you are in bed rather than going to the entrance door to switch off/on light. That is the 2-way switch. What we provided is 2-gang 2-way switch which means one gang is controlling center light and the other controlling wall bracket light. We have dimmer switch as well which we normally use for chandelier and dining light. List of different switches: 1-gang 1-way(means one button and u can only switch it on/off in one location 1-gang 2-way(means one button and u can switch it on/off in 2 different locations but there is what will called COMMON(engineering terms) but technicians normally call it traveller. The 2 switches must be connected together with traveller. 2-gang 1-way(means two buttons and u can only switch it on/off in one location. 2-gang 2-way(means two button and u can only switch it on/off in two different locations 3-gang 1-way(means three button and u can only switch it on/off in one location I will upload pictures later |
Call us today |
Delmac73:Noted!!! |
For your offices. Call us today |
segcymoor:Lovely design. |
Good, royal garden estate is like 2mins drive from Ajah round about. The estate is very nice but land expensive there. Good job oga segcymoore. More power to ur strength |
Thanks for calling. |
HsLBroker:@HSLBroker. This issue can be resolve amicably, forget about what happen to you and allow peace to rain. God will continue to protect you. You are in the best position to resolve the issue with Jonnyeghosa and Dr. Since doctor confirmed that your work has no issue. God bless u |
HsLBroker:This is serious |
The type of pipes used in residential building is as follows: -100mm(4-inch) UPVC pipe:- for soil and waste I.e from WC down to the septic tank/soakaway -75mm(3-inch) UPVC pipes:- normally use for water collection and for the AC sleeves as well. -50mm(2-inch) PVC pipe:- for collection of waste water from shower, wash-hand basin,, kitchen sink to the nearest manhole/chamber. 100mm pipe will take everything from the chamber down the soakaway or to the nearest gutter/drainage -40mm, 32mm, 25mm pipes:- Mostly use for water distribution from the overhead tank to the surroundings where we have toilet and kitchen. -20mm, 15mm PVC pipes:- Use in the toilet, kitchen for distribution of water. Copper pipes:- use for the hot water line. If client is not ready to install water heater in the house there is no need for copper pipes. -HENCO pipes:- Good for cold water and hot water suplly pipes. The pipe is one of the best pipes with 50yrs guarantee but very expensive. (From Germany) -PPR,TECHNOGREEN pipes:- Good for cold water and hot water suplly pipes. The pipe is one of the best pipes with 50yrs guarantee but very expensive For further info call 08033643191 or 08051750560 Whatsap: 08033643191 Pin: 24ED26C9 Email; atope23@live.co.uk, topselg.engineering@gmail.com You can visit our thread: https://www.nairaland.com/1804476/complete-package-design-drawing-electrical https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9 |
twinskenny:@twinskenny, most client don't believe in electrical and mechanical drawings. They will come to site and tell you the number of lighting point and socket outlet they need. They believe in giving instructions on site rather than having the design drawing which is not the best for the installer. Many clients don't believe in electrical, mechanical and structural drawings. What they know is Architectural drawing. All these drawings are very important in building construction. For the Electrical and Mechanical drawings we have: -DESIGN/WORKSHOP DRAWING:- These are the drawings needed during the installation and contruction of a project -AS-BUILT DRAWING:- normally issue to the client after the installation/completion of the project. We normally submitted it together with operation and maintenance manual. A lot of things must change during installation e.g location of switches and sockets, addition of lighting points and other things. |
! |
Congrats my bro. God will see u thru. You have done the major aspect of the project. Its nice to be landlord. |
mavverick:For electrical and mechanical(plumbing) design and installation. Contact us. or further info call 08033643191 or 08051750560 Whatsap: 08033643191 Pin: 24ED26C9 Email; atope23@live.co.uk, topselg.engineering@gmail.com You can visit our thread: https://www.nairaland.com/1804476/complete-package-design-drawing-electrical https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/9 |
1 2 3 4 5 6 7 8 ... 171 172 173 174 175 176 177 178 179 (of 212 pages)
