Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 8:49pm On Dec 26, 2021 |
Valto: lolz, wahala no de finish. @dollarnaira, @ dam5reey is correct, there is no way, that inverter will consume just 1.1w. u need to a DC meter with shunt, to accurately measure the idle current and the efficiency on load. Imagine checking Idle Consumption from the AC output of inverter and claims that's the 1.1w the inverter is consuming and Still Stand by it.. Some people don't want to learn jare.. I rest the case.. Even Victron no be 1w, lol |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 8:45pm On Dec 26, 2021 |
dollarnaira: U don't get it bro. U sound too Authoritative again. Sounding too proud.
Read this thread from first page 1 and begin by calling each out to remove a post as if u created it. It is my opinion and I am not liking ur response. Too AUTHORITATIVE...No one is an Island of knowledge here.
How does the last line u posted sounds to you? Even a 5 year old will Authoritatively tell you 2+2 is 4 and can never be 3.. Because it's a proven fact.. And confidently correct anyone regardless of age or knowledge that says otherwise.. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 8:21pm On Dec 26, 2021 |
dollarnaira: As cheap as souer 1000w is it can never take 6w. Hope I can use this to checkmate power P=IV P= 0.15A(or less)× 12v = 1.8w LOL I have tested several of these inverters the proper way.. so rest If you don't have the tools to conduct the test and Remove the wrong information Where did you get the 0.15A from spec sheet, post pictures.. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 8:16pm On Dec 26, 2021 |
ewizard1: Because it's on directly on the battery's path before the switching starts. The button/switch to open the gate to the inverter is inside the inverter.
The consumption exist just for the charge up. When its filled, that's all.
That's why after the first spark, if you remove the battery for like 3 seconds on reconnect, it doesn't spark. Because the capacity is still charged. Assumptions, Get a DC meter and Revert.. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 8:14pm On Dec 26, 2021 |
dollarnaira: Bros u too dey authoritative Not good. We are not writing exam with it. I don't understand what you mean.. So I should I agree with False information even when you have stated how you arrived at 1.1 which is totally Wrong.. Accept you are wrong and take the 1.1w information OFF.. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 7:02pm On Dec 26, 2021 |
ewizard1: Capacitor is been charged up. Yes, but you didn't switch on Inverter na... Why is it charging capacitor ? So Idle Consumption exist.. and no load consumption exit case closed |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 7:00pm On Dec 26, 2021 |
ewizard1: Should this be used for all inverters. What about inverters that doesn't have these? There is still small current flowing out.. can be 0.1w Not total idle.. battery is only Idle when nothing is connected.. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 6:58pm On Dec 26, 2021 |
dollarnaira: What do u expect Na wetin i know na  So Please go and Remove that claim for 1w idle consumption from your post.. it was a conclusion based on assumptions and not a correct way of testing... It's misleading.. It's should be 6w to 15w based on few I have tested |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 6:55pm On Dec 26, 2021 |
odimbannamdi: Baba, you forget to upload the picture o...lol
Well, as people say, we are all a product of our own realities.
This information is coming as a shock to me because the three inverters I use do not have indicator lights or screens that stay on even after switching off the inverter (with the terminals connected to the battery). The closest to an indicator one of the inverters have is a screen that shows the voltage of the battery or so. But even that goes off when you switch off the inverter. So I never would have thought that power could still be consumed by the inverter from the battery even after switching it off.
However, I am inclined to believe you because inverters typically make a spark when connected to a battery, accompanied by a beeping sound most times.
Well, the outcome of a DC meter test will give us more insight.
But it is just scary to think that even when not switched on, village people could still use the inverter to sap my batteries...  The consumption is very negligible, 1w there about.. The Question is why do you experience that when you have the Power Switch turned OFF.. That's not enough to believe, Just get a meter and check.. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 5:23pm On Dec 26, 2021 |
@ odimbannamdi NL email no dey work for me.. See this Luminous inverter for example it has some lights on it.. which comes on as soon as you connect to batteries... Maybe those lights comes up with magic.  no mind me oo So those little lights or meter on your inverter will consume power even Switched OFF, I hope you are clear now? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 5:11pm On Dec 26, 2021 |
odimbannamdi: Thanks for the response, sir. But just to be sure you got my question right:
If an inverter is switched off, but still connected to the battery, will it still consume power/energy? Get a DC meter with a Shunt, Connect to Batteries before connecting inverter.. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 5:09pm On Dec 26, 2021 |
dollarnaira: All I know is that wen i plugged my energy meter to my inverter without spec sheet , then plug my ac cable, my energy meter reads 1.1w,and other details. By d time i turn on my trusted akt 5w bulb it jumps to 6.1w and it goes on and on....
Even manufacturers get surprised at times after a product is fully operational shifting a little from spec sheet or shit  You are measuring Inverter No Load consumption from AC Output LOL FYI, The 1.1w is the Energy meter consumption.. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 4:40pm On Dec 26, 2021 |
[quote author=dollarnaira post=108832954][/quote]Post the spec sheet, for your inverter and not a random google post.... |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 4:38pm On Dec 26, 2021 |
odimbannamdi: I am not sure I got you right.
Are you saying, when an inverter is switch off, but connected to a battery, it will still be consuming power/energy from the battery?
Please clarify us Yes, it consume power when connected, Idle.. It also consume power when powdered on.. no Load.. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 4:17pm On Dec 26, 2021 |
dollarnaira: What are u saying? Which one is mislead ppu. Can u differentiate btw idle and no load consumption? Because I no really understand u.By the way how do u test "No load consumption"? Idle Consumption is what the inverter consume when Switched off.. No load consumption is what inverter consume when Powered on and nothing is connected.. Efficiency is how much power does the inverter need to power of 100w load.. the ratio of Load (output)power to Input power |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 4:11pm On Dec 26, 2021*. Modified: 3:22pm On Jan 03, 2022 |
Dam5reey: [s]Neatly used 24V, 2.4KW Hybrid MPPT 25A, 102VOC, 1000w PV input Pure Sine Wave
100k Price drop 90k Still available Manufactured March 2021[/s]
Sold
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 3:58pm On Dec 26, 2021 |
dollarnaira: My Souer 1000w inverter (msw) takes just 1.1w while my 1600w psw uses 1w idle consumption. Stop misleading people, we are interested in No Load consumption and efficiency.. Not Idle Consumption.. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 10:25am On Dec 25, 2021 |
Michaelondon53: Also I don’t know which component is lying maybe the inverter that doesn’t know how to calculate simply or the lonton company with all their crazy nos of watts inscription on their bulbs. My inverter load last night red 16% I.e 160 watts of a 1kva with just tv of 70watts, one 12watts bulb and one 5watts bulb. Inverter took 30watts running on the battery. Calculating that should amount to
70+12+5+30= 117watts!!! Why then is the inverter reading 16% (160watts) where did the 43watts come from??� The problem I noticed here is that you don't know 1. Your inverter Idle consumption 2. Load consumption. First step when going Inverter Route is KYC (Know your Consumption Energy) Get a DC Energy meter to calculate your energy usage directly from the Battery.. They are not Cheap, Around 10k plus shunt with this you will know the consumption as well as the Battery capacity... Your 100AH might not be 100AH too.. or used cell Also those Inverter 16% or load are not Accurate.... |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 11:24am On Dec 24, 2021 |
dollarnaira: When brought down,run the set up while down yourself.
*No two terminals must touch *Battery to cc first *Pv to cc *Then support d panels at different angles *Check results especially if your cc can display amp. * Get a friend or family member to check.
Your set up is small, try do it yourself. In addition he can use a cylindrical container, like cup, Malt can etc.. around 12 noon tilt until there is no shadow.
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 8:39pm On Dec 23, 2021 |
Mustiboy: I'm sorry Sir
I wasn't aware of this thread and just left it all to the supposed expert.
This thread has opened my eyes to a lot of things I can understand now, it's good you have seen the light..  Some installer sha.. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 9:13am On Dec 23, 2021 |
Mustiboy: Thanks, Chief. I really appreciate your prompt response
1. By 12v system, do you mean the 1.5kva inverter I'm using? However, for me, MPTT is an overkill, since I have just two panels and a 100amps battery. Moreover, the installer already connected the panels directly to the battery. So the PWM charge controller is not connected. I don't understand why you should allow that in the first, in this age, if you are able to Comment on Nairaland, I feel you should be able to do simple research about Charge controller and why you should not Connect panels to batteries directly.. make use of Google my friend.. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 4:00pm On Dec 19, 2021*. Modified: 3:25pm On Jan 03, 2022 |
[s]Neatly used 24V, 2.4KW Hybrid MPPT 25A, 102VOC, 1000w PV input Pure Sine Wave
100k Price drop 90k Still available Manufactured March 2021
Negotiable[/s]
Sold |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 6:56pm On Dec 17, 2021 |
mustaphagreens: Thank you, Valto. I will try this. I feel you want to waste my Adding Wire, Instead Wire in Series and use money to add two more panels.. I have same the 6mm 26 yards, There is no Voltage Drop.. with 4 270w (2s2p).. at MPPT I get 60V and VOC I get 72-77V Also on your current setup Measure Voltage at the Panel, and at the end of controller without and without load to see if there is voltage drop or not |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 6:34pm On Dec 16, 2021 |
Valto: i stand to be corrected. this is a fake mppt. try buy a real mppt Cc as the pwm cc u are using is not good enough. Looks like it, I suspected the Controller too.. PWM in disguise.. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 6:28pm On Dec 16, 2021 |
mustaphagreens: Only my phone and pc are always plugged in while the battery is charging. Max voltage I have gotten is 13v (while on charge), my battery should read 14.4v (I only get this with gen or NEPA) when fully charged. As for the panel orientation I don't know much about it o. How can I check the current produced by the panels? This your Controller self, A 12V batteries don't charge at 12V why is yours showing 12V Ensure the Controller is charging at recommended voltage for your Tubular batteries |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 6:08pm On Dec 16, 2021 |
mustaphagreens: Chai! I got two 350W panels some weeks ago. Both connected in parallel and are still unable to charge my 12v 200ah mopower battery full in a day. So many factors can contribute to this, Is your batteries taking full AMPs from the panel, Is your panel Optimized for Best harvest, do you use while Charging, is your controller efficient enough, etc.. you might have Good Panel but consider other factors too |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 10:34pm On Dec 15, 2021 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 12:14pm On Dec 15, 2021*. Modified: 3:23pm On Jan 03, 2022 |
Dam5reey: [s]Neatly used 24V, 2.4KW Hybrid MPPT 25A, 102VOC, 1000w PV input
100k Price drop 90k Still available [/s]
SOLD |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 9:27am On Dec 14, 2021 |
@ generalstingz It's like you sent mail, you can reach my phone 081323-944.78 |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 9:12am On Dec 14, 2021 |
ceaser: @ Ojesky.
"PV Risen 390w X 8, Sunfit 280w x 9, Prime 380w X 7"
So I was wondering how you configured your 7 pieces prime panels.
Your system is 48v The Risen is 390w in 2s, Sunfit 290w in 3s, I guess (stand to be corrected though).
How does the the odd number 7 pieces 380w work out?
NB. I'm trying to use this to work out some possible new upgrades. He has 2 PV input, Also High VOC input allows Odd numbers.. 2s and 3s Ke Simply series until you get to 450V |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 4:59pm On Dec 13, 2021 |
olopan: This seems right up my alley, there is propsective project I am looking forward to and I hope to get four of this if quantity is available.
Still researching more but the info so far is looking promising 1 unit is what is available. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by Dam5reey(m): 1:34pm On Dec 13, 2021*. Modified: 3:25pm On Jan 03, 2022 |
[s][quote author=Dam5reey post=108190910]Neatly used 24V, 2.4KW Hybrid MPPT 25A, 102VOC, 1000w PV input 100k Still available [/s]
Sold
|