Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 10:14am On Mar 07, 2021 |
Mup4life: Thnk you how many pipes make a bundle? 25length Also we have other cheaper pipes in the market but hardly bend and created a lot wastage on site |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 10:01am On Mar 07, 2021 |
Mup4life: Pls what is the current price of :
1. Three phases DB d4. Schneider or ABB
2. 20mm and 25mm pvc pipes.
Cc topsy23 D4 ABB is 46000 Schneider 44000 Original DIGNITY pipe as at yesterday. Price of electrical materials are not stable these days..We contractor are really facing serious challenges in terms of materials cost ... 20mm 9000 25mm pipe 10500 |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 1:02pm On Mar 06, 2021 |
Focusmind: Yes Topsy, my concern mainly is on the unit price. We know how to handle quantities. The picture is not clear enough |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 12:43pm On Mar 06, 2021 |
PAPAFEELERS: Please is this a fair qoute? and if anyone know where one can get good quality ones in Abuja, kindly share. Buyiing direct from manufactuerer is preferable because of the margins in comparison to buying from open market where one will not be sure of the quality. cc:NE3T , Rotech, TwinnsKenny etc please help out Why having 4coils of 16mm? what is the size of your project. Cable manufacturer increase price recently. |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 12:40pm On Mar 06, 2021*. Modified: 1:00pm On Mar 06, 2021 |
Focusmind: Good!
My plumber sent this for plumbing work completion. Note that some internal plumbing work has also been done. Are the prices ok for the stated materials? Sorry, the background from where he took the picture looks faint and blurred. We can not say anything about the quantities because there is no mechanical drawings |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 6:03am On Mar 05, 2021 |
Call us today.. |
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 7:29pm On Mar 02, 2021 |
Rexology: There is no water heater, should I still go ahead with the 6way 3phase? 4-way 3-phase should be okay ABB 48,000 Schneider 46,000 |
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 3:05pm On Mar 02, 2021 |
Rexology: @topsy23, please what capacity of DB is ideal for a 3bedroom bungalow?
What is the price of the original and the cost of sending it to Makurdi. For a standard 3bedroom flat with the following features AC 4nos Water heater 3Nos Cooker unit 1 lighting point Socket outlet External light 6-ways 3-phase is okay for the total load Price ABB 64,000 Schneider 58,000 cost of transportation to Makurdi is around 5,000 |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 5:52pm On Mar 01, 2021 |
Hatesin: Happy New Month to the Honourable House. Please, am confused as to the right Electrical materials needed for the electrical wiring of a 3 bedroom bungalow. Need help..... Send me your plan to 08033643191 |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 9:09pm On Feb 28, 2021 |
Coleman is set to increase price of cables tomorrow...
God help us in this country |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 7:15am On Feb 28, 2021 |
Happy Sunday to you all |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 9:18am On Feb 27, 2021 |
shogbenga: The plan is for a building in an estate. I am only allowed to modify the interior. The windows and doors must remain where they are. Thanks There should be a door at the kitchen area |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 3:00pm On Feb 26, 2021 |
Thanks for your calls |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 2:48pm On Feb 25, 2021 |
|
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 2:15pm On Feb 25, 2021 |
Sent to Kano this morning.
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 9:49am On Feb 25, 2021 |
We are here to give you the best |
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 9:22am On Feb 25, 2021 |
nelsonB: Good morning @Topsy23 how many way distribution board do you advice for a mini 4 bedroom duplex... Please email cost both ABB and Snyder and way bill to portharcourt to helen4free@yahoo.com. Thamks Sir, did you get my mail yesterday |
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 10:41am On Feb 24, 2021 |
nelsonB: Good morning @Topsy23 how many way distribution board do you advice for a mini 4 bedroom duplex... Please email cost both ABB and Snyder and way bill to portharcourt to helen4free@yahoo.com. Thamks Thanks for visiting our thread. I have sent the mail to you |
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 1:28pm On Feb 23, 2021 |
Thanks for your patronage |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 8:42am On Feb 23, 2021 |
Delivered to ikorodu
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 5:25pm On Feb 22, 2021*. Modified: 9:43pm On Feb 22, 2021 |
REMARKS FROM THE CLIENT.
[2:36 PM, 2/21/2021] Client : Thank you. My sister is a good person in eve upry way and I understand you have worked hard, professionally, and competently. It's the least we could do.
My regret is we could not use you for the original Installation but that is another story.
I have a series of initial positions I will set out in following notes due us to consider, at least until I receive the final report. [2:37 PM, 2/21/2021] Client. We are paying for 3 phase supply, have a 3 phase generator, 3 phase DBs and PHCN meter - but only connected to one phase? I can understand if the upper apartments are single phased but the ground floor and outbuildings need to be distributed across 3 phases. [2:37 PM, 2/21/2021] Client. The earthing system needs to be restored as a matter of urgency. |
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 7:42pm On Feb 21, 2021 |
More pictures
|
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 7:34pm On Feb 21, 2021 |
Call us today |
Properties › Re: I Need A Surveyor & architect In Ibadan by topsy23(m): 4:22pm On Feb 21, 2021 |
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 4:04pm On Feb 21, 2021 |
These are observations, all these will be well detailed in our report and add any other necessary ones. |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 3:58pm On Feb 21, 2021 |
|
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 3:08pm On Feb 21, 2021 |
sinorte: Kindly reach out if you can make the TV stand below and/or any other similar designs. Contact Dominionng |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 3:02pm On Feb 21, 2021 |
More pictures from the Power Quality Analyser
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 2:58pm On Feb 21, 2021 |
In the main power distribution room, the power quality analyser was plug for about 3hrs to monitor and examine the quality of power distribution within the facility, below are the picture updates and our observations
* The supply voltage is healthy * A single phase distribution system is noticed, with all loads on blue phase only. The other two phases are abandoned. This will caused unbalanced load the 30kVA generator, and effect is damaging. * Excessive current is seeing on neutral line. * No earthing system around here. * Load on blue phase alone gets above 200A * Frequency is normal *Harmonics is fine
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 2:52pm On Feb 21, 2021 |
More pictures
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 2:38pm On Feb 21, 2021 |
The concluding test on the 4nos. Distribution boards
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 2:27pm On Feb 21, 2021 |
Some circuits are having appropriate voltage while some are having high and other are low. Pictures below
|