Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 2:13pm On Feb 21, 2021 |
We are concluding the last part of the power audit today. We worked on 4 DB's on the ground floor as we plan to catch up with last flight to Lagos.
Pictures show below are before and after ...
|
Properties › Re: I Need Quotation For Plumbing And Wiring For Three Bedroom And Two Selfcontain by topsy23(m): 8:06am On Feb 21, 2021 |
baobab1: Hello Topzy, pls send to okikialonge1@gmail.com with your WhatsApp number pls Email sent sir |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 8:44pm On Feb 20, 2021 |
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 8:37pm On Feb 20, 2021 |
We are carried out some test today. Below are our are the pictures and observations
Picture 1: The voltage supply into the DB is healthy as seeing on the fluke tester.
Picture 2: Neutral to earth, the voltage seeing is too high. The ideal voltage should be less than 1. This is often caused by leakage or non functional earthing system.
Picture 3 : Line-earth, the voltage seeing is a further indication of leakage within the system as such high voltage isn't supposed to be present.
Picture 4: Loop impedance, this of course will never pass since there's no functional earthing system, and the voltage between earth and neural is too high. Equipment used is Kewtech
Loop impedance is simply a proof of good earthing system and a pathway of low resistance for fault current to follow through into the earthpit without damaging live and property. It's also an assurrance of a proper MCB breaker selection capable of tripping when there's fault or high voltage before damaging appliances.
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 8:29pm On Feb 20, 2021 |
n3xt: Good job bro. I think I've found a better and more experienced electrical contractor as a replacement for my late electrician.
May I ask this question? Do you offer circuit diagram or wiring diagram after every installation? If yes, that's good. If no, please kindly consider it as a value-added service.
The circuit is used to show how the circuit functions. It shows the components of the circuit and how to make the connections between the devices.
There are few install I did years back that I really wish I had considered having these drawings. We offer As-Built drawings for client who requested and ready to pay for it. |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 8:05pm On Feb 20, 2021 |
Electrical final sub circuit termination. We did a thorough cable tracing and carried out some dead test before the termination. unprofessional installation.
The electrician connected a single phase line and looped the other phases. Cable colour code matters alot in electrical installation.
The DB's are 8-way 3-phase which is is suppose to have 24nos of outgoing breaker. but we could not find the other breaker but we make sure we re-terminated all the cables on the available breakers.
The client's made a good choice by installing SCHNEIDER Electric distribution boards in all the floors
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 3:09pm On Feb 20, 2021 |
Disconnection of final sub circuit for us to carry out dead test... i.e continuity and insulation resistance test
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 3:07pm On Feb 20, 2021 |
|
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 2:17pm On Feb 20, 2021 |
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 1:53pm On Feb 20, 2021 |
Watch out for the revamp work
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 1:52pm On Feb 20, 2021 |
More pictures
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 1:51pm On Feb 20, 2021 |
We are here once again for quality and standard installations. All the way from Portharcourt in Nigeria, We received an email that we should come for Power Audit in a recently completed project(RESIDENTIAL BUILDING). We gave them our proposal and we later agreed to carry out the power audit exercise.
On getting to site we met a very poor and unprofessional job done by local electrician.
Our aim is to carry out all the necessary electrical test with the aid of using the beow equipment Kewtech Power quality Analyzer fluke
All the test to be carry our are: Continuity test Insulation resistance test Loop impedance test Load consumption test Earth test etc...
Below are some pictures of electrical installation done by local electrician
|
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 1:46pm On Feb 20, 2021 |
Watch out for our revamp work
|
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 1:45pm On Feb 20, 2021 |
More pictures
|
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 1:43pm On Feb 20, 2021 |
We are here once again for quality and neatness of our installations. All the way from Portharcourt in Nigeria, We received an email that we should come for Power Audit in a recently completed project(RESIDENTIAL BUILDING). We gave them our proposal and we later agreed to carry out the power audit exercise.
On getting to site we met a very poor and unprofessional job done by local electrician.
Our aim is to carry out all the necessary electrical test with the aid of using the beow equipment Kewtech Power quality Analyzer fluke
All the test to be carry our are: Continuity test Insulation resistance test Loop impedance test Load consumption test Earth test etc...
Below are some pictures of electrical installation done by local electrician
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 12:03pm On Feb 18, 2021 |
Call us today |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 11:42am On Feb 17, 2021 |
n3xt: Thank you sir.
Don’t forget to check me at our headquarters shop kobocity.com
Na there bebe dey shele. If I lie, ask fellow kobocitizens @thomaths @folmus @topsy23 @mank1234 Yes oo boss.. Really appreciate Mank1234. God bless you sir |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 1:05pm On Feb 14, 2021 |
Happy Sunday to you all.
Don't forget we are here to give quality materials and installation
WhatsApp us today 08033643191 |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 8:09pm On Feb 13, 2021 |
Materials sent to Eket Akwa Ibom State and delivered
|
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 12:51pm On Feb 13, 2021 |
Cribking1: Good morning all, I want to thank everyone who has helped in solving this issue. Special thanks to Kobocity for his swift response and professionalism . Mountmoriah has delivered the roofing materials and installers are currently installing them. I was very nervous because of my previous Fraud experience on this platform. Also, the gap of communication he created exacerbated the whole situation. Sure, there was sinister motive behind his silence but thank God I acted fast. My advice to anyone dealing with contractors on this platform or anywhere else is to be on your toes.... Thank God for safe delivery |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 10:42pm On Feb 12, 2021 |
Cool
|
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 10:34pm On Feb 12, 2021 |
erico2k2: To calm my man down that guy should have snapped pictures of materials and send it to him so he can sleep well, We don't want any BP rise My thought boss, he should pictures and also pick his call. Communication is very important |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 10:29pm On Feb 12, 2021 |
Cribking1: It was this Nairaland and Kobocity testimonials that made me to fall for his scam . Be patient sir. Let us wait till tomorrow morning since it was confir.ed that he's on Iwo road |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 4:45pm On Feb 12, 2021 |
Thanks
|
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 2:32pm On Feb 10, 2021 |
Good afternoon |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 8:08pm On Feb 07, 2021 |
doe: Please how much is 16mm and 25mm armoured cable. Email dooosak at Gmail dot com Mail sent sir |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 8:01pm On Feb 07, 2021 |
Delivered yesterday
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 5:02pm On Feb 07, 2021 |
Jalofun: No drawings to the plan. Mail sent to but below are the list of standard electrical installation. Thanks ANTE ROOM spot light 2nos 13A double socket 2 13A single socket 1 Tv 1 AC 1 SITTING ROOM spot light 6nos 13A double socket 4 13A single socket 1 Tv 1 AC 1 BEDROOMS spot light 4nos 13A double socket 3 13A single socket 1 Tv 1 AC 1 TOILET Ceiling light 1nos Shaver socket 1No Water heater 1No KITCHEN Ceiling light 4nos 15A socket 1No Cooker unit 1No Water heater 1No |
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 11:51am On Feb 07, 2021 |
Original AC copper pipes delivered to a client
|
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 11:46am On Feb 07, 2021 |
doe: Please how much is 16mm and 25mm armoured cable. Email dooosak at Gmail dot com Okay sir |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 9:51am On Feb 07, 2021 |
Jalofun: It's just a 2 bedroom bungalow.. So that you will handle both the mechanical and electrical installations.
I Ok sir can you send me the drawings WhatsApp number 08033643191 or topselg.engineering@gmail.com |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 9:26am On Feb 06, 2021 |
Jalofun: Hello sir, can you work on my small project in ondo State? Yes we can handle it |