Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 7:45pm On Feb 25, 2018 |
Kiekie1 pls respond samnaija: Thanks for the help. Would look into flexmax 80a . Any idea on price range |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 6:29pm On Feb 25, 2018 |
The bigger the panels the better  . You could get a bigger charge controller of 80A like Fangusun flexmax 80A or Midnite classic of 90A. You could also split the panels... 6 on the itracer and 2 on a 40A EPSOLAR (this I have  ) samnaija: Are the panels on the large size. Because the epsolar states 1600watts for max power. And the 8 in number. Do you suggest I return them for smaller sized panels. Will appreciate need to make a decision. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 5:33pm On Feb 25, 2018 |
This is dicey... But if d distance btw array n charge controller is not long and you can get 16mm cables, then I recommend parallel samnaija: The panels 320watts Voc is 45.07v. They are 8 in number. Tnks |
Science/Technology › Re: How my inverter is saving me in this poor power supply and no-fuel situation by DMerciful(op): 10:33am On Feb 25, 2018 |
DMerciful: Hi Guys,
Contact me for your brand new epever 12/24V 40A MPPT solar charge controller @ 60k Fangpusun FLEXmax 60A 12v/24v/36v/48v/60v @ 140k If interested Whatsapp me on 08035415969
Cheers. |
Technology Market › Re: World's Smallest Power Inverter by DMerciful(m): 7:37am On Feb 25, 2018 |
For sale. Brand new mppt solar charge controllers from different brand. Epsolar 12/24v 40A mppt @ 60k Fangpusun blue controller 12/24v 50A@ 64k Fangpusun 12/24/36/48/60v 60A @ 140k
Solar installer for professional solar installation
Whatsapp me... See number on my signature |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 7:10am On Feb 25, 2018 |
What is the Voc of the panels? U can get this info from the name plate. What is the wattage of each panel and how many panels in total? samnaija: Guys a 24v 500ah system. What's the best panel configuration. If your are going to use12/24/48v epsolar mmpt charge controller 60a. The max power is 1600 watts for 24v system. Is it better parallel all panels or double the PV volts. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 8:17pm On Feb 24, 2018 |
The first pic is a watt meter or energy meter. Measures the energy consumption of connected appliances as well as other data like voltage, current, power factor, wattage etc davodyguy: Hello team.
Found this, but not sure of it usefulness |
Investment › Re: Treasury Bills In Nigeria by DMerciful(m): 6:49pm On Feb 24, 2018 |
U are just rude! zinaunreal: everybody is focused. But ive noticed you people still don't want to ignore a few comments on quilox so continue showcasing your immaturity here. Rubbish. What would it take for you not to comment and move on. I cease to comment any futher. If una like start employing people on this thread like say na company. Na your forefathers get am |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 12:51pm On Feb 24, 2018 |
Funny when at investment stage the wifey will be like why are u spending so much. But at the benefit stage they can't do without it  davodyguy: Wow. Yours is super. I'm currently doing 200watts. Its safe to conclude that I'm losing batteries, cos the 10amps can't do anything.
My wife is on my neck and since we work to take care of the family.
If the batteries start showing, signs of being low, I'll put on the gen.
My aim is to increase my system by end of march, 2018.
I'll get 2 more 300 watts panels to take my system from 600watts panels to 1200 watts panel |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 12:19pm On Feb 24, 2018 |
Led TV and fan should not be more than 70w....mine is 42inch led TV and it's 50w and fan 20w davodyguy: Wow. Yours is super. I'm currently doing 200watts. Its safe to conclude that I'm losing batteries, cos the 10amps can't do anything.
My wife is on my neck and since we work to take care of the family.
If the batteries start showing, signs of being low, I'll put on the gen.
My aim is to increase my system by end of march, 2018.
I'll get 2 more 300 watts panels to take my system from 600watts panels to 1200 watts panel |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 12:01pm On Feb 24, 2018 |
Davodyguy, You are right the sky is very cloudy and I am only getting 232w fortunately my 'convenience loads' are less than 180w so net my battery is charging a little. Look at it this way, you a filling a bucket at a volume flow rate of 10m3/s and draining at 15m3/s....net you are depleting your reserve. For mains, the inverter takes enough power from the grid(we can say the grid power is unlimited comparatively) to power the load and charge the batteries. I have an analogy meter that tells me if the batteries are being charged or discharged and by how much depending on the needle direction. For light loads like TV, fans and lights, I use a small inverter of less than 20k but very efficient while I use my mustpower 3kva for heavy loads like AC, pumping machine, iron when needed. See pics below davodyguy: Hello chief niyi and Dmerciful
It rained heavily last night and the effect is seen on the sun right now, very poor now in Lagos
My Panel is sending 3-4Amp to the batteries.
I want to use the inverter now and still allow the Panels to continue to charge. My question is if I load the batteries now, will the load be on the batteries by draining them or it would be like normal electricity that charges batteries and also supplies power without depleting my batteries?
I hope you get my question
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 8:52am On Feb 24, 2018 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 8:36am On Feb 24, 2018 |
To make a comparative analysis you have to keep certain variables constant. I did not change my loads to get this harvest infact nobody was at home just my regular loads on inverter. Also you did not question the numbers shared for the premium panels but you want to question the conditions surrounding this one  Barezzi: This is not entirely true, as harvest is proportional to usage. You squeeze every juice from your array cos house energy usage far outweighs production, hence your fantastic efficiency numbers. |
Investment › Re: Treasury Bills In Nigeria by DMerciful(m): 8:24am On Feb 24, 2018 |
Loool..you want us to join them Alikote: truck drivers even halt to have sex to refresh the mind and still deliver product to filling stations |
Investment › Re: Treasury Bills In Nigeria by DMerciful(m): 7:11am On Feb 24, 2018 |
He advised we stay focus on the intent of the thread without derailing and I think he is right. If you are travelling from Lagos to PH and you want to stop for eating you go off the road to an eatery! U don't eat on the road. If you need to unwind, go to romance section afterwards you can come back rather than derailing this thread. Stay focus guys zinaunreal: it would have been wise for you to keep shut and get on with the TB discussion rather than lecture us on what we already know Mr Minister of Education. Taking the heat off sometimes aint bad. Youre asking for correlation. When ever you drive from lagos to portharcourt don't stop to take a break and eat eba and better soup keep on driving till you suffocate. Coz you own a car and others use public transport doesnt make you a robot. You must divert to eat. Youre asking correlation
Youve actually dragged just a few comments that isnt even up to four peoples opinion and made it a case. Maybe na you own this thread i guess. You can eat the thread then. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 10:52pm On Feb 23, 2018 |
If I'm told the premium panels are 8%-10% more efficient than the tier 2 or 3 panels then I will be convinced of significant yield difference. For instance the pic attached is my harvest today from a 1.5kw sunshine panels. Meaning if I have 6kw of sunshine, I will be doing 21.2kwh......now compare and contrast! All in all, the difference does not justify the cost difference, my opinion though NiyiOmoIyunade: This then is the price vs. performance paradox that we face in deciding to go with the Premium or Value offering.
KieKie can attest to how many times we haggled bitterly over me trying to get a good price point for supply of Solar World panels over the last 2 years - the guy would give me a quote and I would squeeze him hard for more discounts until he would abruptly end the discussion in frustration.
Using advertised prices on this forum for the larger size 300w range panels, I estimate the price of Premium Tier1 to at least 260naira per watt and a good Value Tier2 to at least 180naira per watt.
If I give the Tier 2 60% efficiency and the Tier 1 STC 77% or let's just say 80% I am still looking at the Tier 1 coming out more pricey. Again I would say 10 years forward is the usage horizon for solar panels because one would always want to upgrade to the latest tech even if the product in use was still performing.
This is the dilemma I face every day in making buying decisions for myself and clients especially those with a large budget. I have come to decide that it's mostly an emotional decision in the end hence I bought two MorningStar units for myself because I believe I can rely absolutely on them even though one Midnite Classic 96A may have done the job at 60% of the cost but simply because of the remote possibility of fan failure in the Midnite I refuse to use it.
|
Politics › Re: Publish All Properties Recovered And Owners Before Selling Them -Fayose Tells FG by DMerciful(m): 10:02pm On Feb 21, 2018 |
Can't you see the sarcasm in my comment? Pecca: What integrity? Integrity entails sticking to your words. Tell me one thing this Mr Integrity has said and stood by it. Is it his boast about foreign hospitals? His asset declaration? Fighting Boko boys from the front and defeating them in 3mnths? The man na bad product jare!! |
Politics › Re: Publish All Properties Recovered And Owners Before Selling Them -Fayose Tells FG by DMerciful(m): 8:07pm On Feb 21, 2018 |
They wanted to hide propaganda by claiming they have sold the recovered properties thus escaping the explanation and prosecution of those behind the stolen properties. Time to test the false integrity of Mr Integrity |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 8:06pm On Feb 21, 2018 |
Lay the panels flat then tilt it 6degrees facing south. davodyguy: Thanks
Kindly advice on the best position they should face. I plan to get another 300watts Panel |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 6:34pm On Feb 21, 2018 |
Sun wasn't that great today and depends on he direction ur panels are facing. They should almost be horizontal but 6• facing south davodyguy: Yes, that's why I asked if what I'm seeing is at its peak
Inverter 900watts 12v 2nos 200amps Gennex Gel batteries 40A E-Smart Charge Controller 2nos 300 watts Panel
From 8:00am to 2:30pm with sun, the best I saw was 27amps dropping into my batteries.
Ha e I been scammed?
 |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 7:58pm On Feb 20, 2018 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 8:22pm On Feb 18, 2018 |
If your cc to battery breaker trips when there is no short.-circuit then it means it's not properly sized and this could cause cc failure. If it were EPSOLAR cc it would have positively failed. You seemed to have experienced what is called solar flare where the luminosity is more than 1000w/m2 and as such panels give more than their rated capacity as their capacity is usually rated at 1000w/m2. Key take out is for you to size ur breakers correctly Ijeoma660: Please who can explain this phenomenon.
I experienced this upsurge about two days ago before midday. It kept tripping my CC to Battery bank outgoing breakers. I kept closing it back, then it tripped the PV to CC incoming breaker. After which I allowed the system to relax.
PS: I looked out of the window and noticed the sun wasn't as bright as there were scattered low lying clouds in the sky. But the sun's intensity was so intense through the edge of the clouds with shadows showing clear and distinct outlines around objects!
Still wondering why... |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 10:32pm On Feb 16, 2018 |
With your array and battery bank... You should get longevity cos the stress on individual battery is low and enuf array to ensure full charge daily. When I grow up sha  NiyiOmoIyunade: The plan is not to need new batteries for the next 5 years at least. 
Fingers crossed on how the future will actually turn out!!!
If I can get battery longevity results like Oga GeorgeD then I will be a happy man indeed |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 10:14pm On Feb 16, 2018 |
With this kind of battery bank,do you really need lithium batteries? NiyiOmoIyunade: Your observations are correct same as Oga KieKie - Flooded batteries kind of have lower voltage profiles than sealed maimtenance free batteries and their Voltage vs. State of Charge charts typically reflect same.
I also noticed that this apparent low voltage is more pronounced in the Mercury Flooded I first had than in my last set of US Batteries for example but I have no hard data to support this.
Interesting that you also are getting disillusioned with Flooded batteries as a quite a few people have been on here - for me Lithium is the next port of call once I wrap my head around all the complexities of a BMS and battery balancing.
To eliminate undercharging issues with your Flooded battery bank please Can you confirm that you give your batteries a proper daily charge? What is your absorb voltage setpoint? How many hours do your batteries spend in absorb daily?
Currently I have 16 pieces of 12v 200ah Gel batteries in a 48v 800ah setup - my voltage generally stays around 50.6 worst case by 6am in the morning. If the Madam had used microwave a lot the night before or the 2hp sitting room AC then I could see 50.3volts - once on a cloudy day where I could not finish absorb and still had heavy overnight usage, I saw 49.75volts by 6am in the morning and mind you I ALWAYS use the 1hp bedroom AC overnight.
So I remove anywhere between 160ah to 260ah between 6pm and 6am daily from a 800ah bank and the voltage stays within the 70 to 80% State of Charge mark.
So far so good excellent batteries and they were sourced from ICelllPower through JUO. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 8:26pm On Feb 16, 2018 |
Transformer types are more rugged... Just the idle consumption kiekie1: I typed 100% ! Its due to distortions you get especially when you load above 50% .. Its not really obvious for those running average loads , its ruggedity can't still be compared to transformer based pure sine wave inverters.. Thanks!! |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 7:09pm On Feb 16, 2018 |
You mean it's modified sine wave?  kiekie1: Ooo sorry for the disappointment on your konga supplies .. You are more safe because you paired up Gennex hybrid "par a & b" .. Its a bit more affordable considering the procurement cost of a 10kva schneider , victron etc without adding extra cost of mppt yet ! It exceeds a million to be factual ... If you operate within safe load range , your inverter system should serve you for years not minding its not 100% pure sinewave !! Cheer's |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 7:00pm On Feb 16, 2018 |
Too much charging current deteriorates batteries faster esp when you are charging with mains and solar, tendency to b charging with over high charge current exist. Also at lower input voltage of 85v coupled with high charging current due to low battery, the stress on the axpert will be massive and might cause premature failure and as such always install a decent stabilizer before the inverter earthrealm: wow, if a transformerless 5kva axpert system has 45w idle consumption, makes me believe the 135w idle consumption rating for the 4kva prag/mustpower. the axpert is really a master piece, i wish it could handle my resistive loads, the wide input range is a big plus 85v to 280v ac, and massive charging current |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 7:50am On Feb 16, 2018 |
 bigrovar: Warning: Coupon is either invalid, expired or reached its usage limit!
Also you might want to work on the process of checkout. It requires the user to be registered (you can't checkout as guest) and the registration page throws up a json error |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 10:39pm On Feb 15, 2018 |
I did some tweaking of my solar array from 3*2 to 2*3 as my itracer is finding it difficult to track the maximum power point quickly on 3*2 config. i did the change this evening so i will observe tomorrow if there is improvement. My panels are fence level so i change easily  . I love the beauty of the axpert though Barezzi:
About 45w each if I remember correctly. When i get home next month, i'll confirm. About 90w*13hrs=1.2kwh by daybreak. Not much, considering my pv array.
Hot water. This particular area nearly gave me high bp, until Dapsyra's tweak! My house is fully off-grid.
How's your system treating you bro? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 9:39pm On Feb 15, 2018 |
Barezzi, Always tweaking ur system  . Anyways... What's the idle consumption of this Axpert? Barezzi: Yes, I have 2 Genex Axpert inverters in parallel mode. It carries everything i throw at it, no issues so far. 5 months and counting!
Each inverter has a 2.6kw array. They've been churning out amps like a demented coyote on heat. |
Politics › Re: Presidency: Our Social Investment Programmes Marred By Fraud by DMerciful(m): 9:04pm On Feb 15, 2018 |
K |