Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 5:37pm On Mar 07, 2017 |
aroseyi: • ANDROID TV BOX WITH AV CORD READY
• Q19G DECODER AND FREESAT AUTOROLE POWERVU DECODER
• WIFI STICK OR ADAPTER FOR 4922A,4950,QSAT,SUPER ESAT,ETC
• IPTV ACCOUNT WORKING IN ANDROID/TABLET AND STB DECODER
• TVSAT, HOTBIRD, HISPASAT, euro bird 9e, MYTV AFRICA CCCAM AND
• CANALSAT REUNION on 16e AND ZAPTV CCCAM on 36e
• SPYCAM/TCAM ACCOUNT FOR ONLY Q11G, Q13G, Q15G, Q23G,Q26G AND Q28G OPENING MYTV AFRICA on 16e
~ 3G/4G PORTABLE Router WITH LAN PORT FOR ANDROID BOX, DECODERS AND PC.
Whatsapp: +2348062272279
Skype: ancl.sy email: ancl1860@gmail.com How is it related here! Do these boxes have inbuilt solar cells & battery? I beg this place is renewable forum not junk room. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 2:39pm On Mar 07, 2017*. Modified: 9:40pm On Mar 07, 2017 |
Obimind1: Pls gurus in the house, ur advice is urgently needed. I noticed that my mppt cc 60ah ep solar keeps charging even when there is no sun. I feel something is wrong somewhere but can't exactly tell what could be the problem. it happens on few occasions don't worry! I use fangpusun 60A MPPT I got from Oga Chris.' initially I love it and kept wondering it is so powerful that it tracks energy from the moon and stars @10w at 0.4 - 0.5 amps and 1-2AH over night. but now I feel it is not worth it so I let my mppt sleeps even when "it feels" it still want to work at night. fangpusun 60A MPPT has a program restart solutions at various point to solve this situation and put it to sleep. if your CC has program re-set, run it in order to sweep or track MPP (in this case it will find non and sleep) OR if you have a DC breaker in-btw you PV & CC trigger it off and later on. worst put off / on the DC breaker btw the battery and CC | am double sure this will reboot ur CC to cancel the problem. However I feel leaving ur CC on will not damage it unless someone has a different view-point My regards! |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 3:50pm On Mar 06, 2017*. Modified: 5:23pm On Mar 07, 2017 |
chris81964: Good Morning Folks,
I hope my message meets you well. Please if you paid someone else to install your solar power for you, don't ask me for advice on fixing it. We charge a fee to diagnose problems on bad installations.
If you are a DIY'er I am very happy to answer questions and offer advice.
There is a clear difference between the two. I do solar for a living and if you are willing to patrnonize someone other than me it is your right. However if you want a performance problem diagnosed it is a minimum of N7500. And if it is an unusually bad job that fee is double am happy you did not slam the door of experience on everyone. In fact you are truly a doctor of solar. doctors admit, treat and get paid bad installations always tarnish image of solar addicts and lead to lower adherents. your decision is splendid !!! |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 9:21am On Mar 06, 2017 |
kiekie1: JUST OFFLOADED Yachi / YahSun Solar P-POLY,M-MONO 80w-P-25k 100w-P-30k 140w-M-42k 150w-P-43k 150w-M-45k 200w-M-60K 260w-M-75k 310w-M-85k Stocks fast running low,call & place your order today WhatsApp: O8I35O3I95I SMARTCELL GLOBAL SERVICES Thumbs up 4 Oga Kiekie1  timely info is important keep it up! |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 7:17pm On Mar 01, 2017*. Modified: 7:33pm On Mar 01, 2017 |
JUO: bros no be me and flooded again oh Na wa oooo Wen those of us with SLA batteries see you people with flooded batteries as big boys (which you are). No wonder LifePo batteries is gaining favour |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 6:45pm On Mar 01, 2017 |
abunafiu: For over a week now. Ilorin sun has been smiling at me. My daily harvest is now 14 to 15.5kwh daily with my 4kw @250w poly panels. 2 weeks ago, I will shout if I hit 12kwh. I almost felt my panels are going down.
Saipro how far ur side?
Finally ve united my Trojans. Back to 48v set up now. So I now discharge gently. Since I am 100% off grid. Saving for additional 1kw to hit 5kw PV strength. After then start saving for battery replacement. Not sure if I would love to have a repeated flooded experience. What about you? Am happi ur system has bounced back. It seem our solar community is having good tidings from north to south. My regards to all. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 11:47am On Feb 27, 2017 |
kiekie1: Yes I know BT for areas with high humidity , dehumidifier is available for purchase .. They work real good as I use 1 in my room. I don't run AC always as I save more with Chillers (Dehumidifier optional)
https://www.amazon.com/gp/aw/d/B013IJPTFK/ref=mp_s_a_1_1?ie=UTF8&qid=1488187874&sr=1-1&pi=AC_SX236_SY340_FMwebp_QL65 Nice work Oga Kiekie1 thanks for the update on Oga Chris observation and bigger thanks to naira that has just woken up from almost a year in Coma & heavily sedated by CBN  you'll hear from me @ appropriate time even if it means selling one of my split AC going green is a commitment and do-able affair.  |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 4:44pm On Feb 26, 2017 |
kiekie1: You are free to always explore as chillers are cheaper than inverter compressor 1hp Aircons.. I have used Scanfrost chillers(170w max consumption & uses 20-30L water reservoir for chilling) in most of my installations and they have been working real good & Scanfrost also provides good customer service ...
Contact me for company price/discounts !! Nice! 170w max is green better than 900w compresior system. I hope the price is friendly green? |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 10:57am On Feb 24, 2017*. Modified: 1:26pm On Feb 24, 2017 |
dapsyra: Harvest is good 
15.9KWH today
15.5KWH yesterday
http://pvoutput.org/list.jsp?userid=46221 hummmmmmmmmmmm am speechless!  NEPA will really hate you ! and may soon bribe you with 'Ghana Must Come' bags to stop opening peoples eye to free sun energy. imagine, see your 15.9 KwH x Nepa rate = (thousands of naira/day) x months or (years of going green) - (initial expenses)=  nice one & good savings! me i still dey 3.4KWH/day Sha! |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 2:03pm On Feb 23, 2017*. Modified: 2:54pm On Feb 23, 2017 |
mcci: Hello Gurus in the house,
Please advise
Current System Configuration: 6 x 250W; 3 x 2 Series-Parallel Configuration; Vmp=30.1, Imp=8.31, Isc=8.71, Voc=36.4 CC: TS-MPPT-60; 3.5KVa 48V Inverter
Proposed new panel specification: 6 x 260W; Vmp=31.4, Imp=8.37, Isc=8.94, Voc=38.4
Proposed System Configuration (1): 3 x 4 Series-Parallel Configuration My concern from varied online source is that old panel would negatively impact new panels and mppt would have a hard time identifying Vmp
Proposed System Configuration (2): 3 x 3 Series-Parallel Configuration; I eliminate 2 old panels and connect remaining 4 in series and parallel to new panels (3x2) I suppose new panels would give maximum power but old panels (1000W) would be pulled down to a max of (780W) I guess.
What do you think the impact on system would be? Please advise.
Thanks you did not specify if panels are mixed that is poly mixed with mono. i assume you are using poly panels please go with config 1. with ur MPPT ur CC will probably pick the lowest values (i.e. Vmp=30.1, Imp=8.31, Isc=8.71, Voc=36.4 instead of Vmp=31.4, Imp=8.37, Isc=8.94, Voc=38.4) at that rate you are granted of harvesting steady wattage for longer time particularly during raining season. @48V battery bank you need all the panels. nice effort too.  |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 12:54pm On Feb 23, 2017 |
kiekie1: Hello 30a a series mppt @ 60-65k , 40a is 70-75k , MT50 black remote meter @ 15-20k .. Thanks Oga Kiekie1 I appreciate u and ur fast delivery as usual! I always thought I was consuming more until I received & installed the watt mater. thanks!  |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 6:54pm On Feb 21, 2017*. Modified: 9:42pm On Feb 21, 2017 |
chikkaobi: Here is the picture of the CC working. Couldn't get the load A, because my inverter is connected directly to the battery. Though I watched some video on youtube which stat that the CC is just a rip-off, because it doesn't have an Inductor, and would waste energy. Any Idea the effect it might have on the battery? If it isn't good, I will be ok if you could suggest a CC. Are u using hybrid inverter? Pls love ur CC. A good CC will save u huge money eventually. left to me just ground Dat ur cc casing with d bus bar for grounding in ur setup. Don't ascribe to + or - earthing till u have funds for dc arrestor Explore other options from guru pls. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 2:31pm On Feb 21, 2017*. Modified: 2:47pm On Feb 21, 2017 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 2:27pm On Feb 21, 2017 |
chikkaobi: Got Charge Controller MPPT30A for a single 200AH battery, however I saw Battery Capacity configuration which says >= 300AH(Meaning greater or equal to 300AH) My question is; Can I still use this charge controller on a single 200AH battery without issue? lets have your full config. or setup by listing them out. few pix can quicken your request from those with similar CC you may also add your intended load! alternatively go back to classroom by reading from page one. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 8:09pm On Feb 11, 2017 |
Onosy: Installer do give different prices for installation of a 5kva complete system. As it stands now I don't even know what the best option, though someone suggested Nickel batteries or FLP batteries Start small but go 4 d best |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 11:22am On Feb 11, 2017 |
cooldipo: Pls we need more contributions to this issue of limit pose by charge controller rating. In my case, I have a 12V inverter set up and a 30A Epever Tracer charger controller with 3 units of 150watt mono panels. The Max Pv input power is 390watt(12volts) 780watt(24volts) for the cc..... I was tempted to add one more panel even though the Maximum Power current is about 8.5A per panel. I wanted one more panel if 150watt for obvious reasons......bountiful harvest on days with less solar radiation which my supplier gave a nod to but my installer here gave me the scare that I run the xtra/over current...... Pls help me out with informed opinion. Thanks Yes! under STC Max Pv input power is 390watt(12volts) 780watt(24volts) falls true for your CC but will you always get those parameters harvested from your roof top? Yes! you stand the risk of blowing up ur cc with the extra/over current that is where you need learn from experience of gurus in the house. for me, you can always tweak by re-configuration of your PV with installation of extra one PV having a slightly lower specs somewhere in your Series & parallel. But observe the 145v / 30A thresholds. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 9:38am On Feb 11, 2017 |
bigrovar: So yesterday I finished series of updates I have been carrying out on my system. The upgrades include an additional solar panel (250w) to my 240w+240w+220w array. I made was to replace my crudely put together battery monitor with victron Energy BMV 700 battery monitor. Comes with a shunt and display too.
Hope to do a product review on the BMV soon. (Fantastic product.) Below are mandatory pictures for sharing your experience, i say thank you ! i love your Tubular batteries too i wish recession should just go to purchase some too. the distance btw battery bank & CC + battery loop seems too long, but you seem to have solve energy loss using rated cables. Nice too! i admire your monitoring meter and its basic installation. it re-buttress what konnection said earlier that we are like hawks watching over our power solutions. I am not comfortable with your cables hanging or dangling from your PVs. I hope you don't have domestic goats around your place or else they may practice "head butt" with it or use horn to test their stamina to impress she-goats.  |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 9:53am On Feb 08, 2017 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 5:14pm On Feb 06, 2017 |
goddyior24: The EPSOLAR Tracer 2210RN 20A is rated at 260w maximum panels. I do not understand. I need clarity. am sure you are referring to the following specs Specification Summary System Voltage 12 / 24VDC Rated Battery Current 20A Rated Load Current 20A Max. PV Input Voltage** Tracer-2210RN 100VDC Tracer-2215RN 150VDC Max. PV Input Power 12V System 260W 24V System 520W *Array voltage should never exceed maximum PV input voltage. Refer to the solar module if you read further on the manual you also find " If the solar input current exceeds the maximum rating, the array will be disconnected automatically". what stops you from configuring your panels on hot sunny day to get the upper limit since it has auto shutdown. let us have your test results when you can carry it out.
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 10:13am On Feb 06, 2017*. Modified: 6:45pm On Feb 06, 2017 |
goddyior24: EPSOLAR Tracer 2210RN 20A mppt controller is rated at 260w maximum solar panels. If you want to go close to the 100v for more efficiency, your panels wattage will be more than the 260w. How can you get 80v still being within the 260w Limit?. I need clarity. Is that what the manual says? why not consult properly from dealers before buying items. most solar enthusiast here will gladly offer you good -free advice without consultancy fee. mind you 20A mppt cc cannot have upper limit of 260w please do your sizing properly to enjoy your sweat otherwise you will think "solar thing" dont work  .  |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 12:49am On Feb 05, 2017*. Modified: 10:49am On Feb 05, 2017 |
bigrovar: Avoid parallel connection if I can. Rather it's always better to go on higher voltage than current. Parallel connection no matter how well installed have a knack for not being evenly charged. hmmmmmmmmmm Voltage (v) versus Current (amp)  lower voltage => lower heat more amps (mppt, pwm) higher voltage => higher heat greater amps (mppt) having battery-cable distance in view. hmmmm true talk! |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 10:30pm On Feb 04, 2017 |
GeorgeD1: richmon,
welcome back from the cold. no doubt 2017 is shaping up to be a very exciting year after all. I completely agree with you. Oga richmon u've stayed away too long. I have everyone here to thank profusely b/cos am enjoying 24hrs electricity with style since I discovered the great house. Thank you all! |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 8:13pm On Feb 03, 2017 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 8:08pm On Feb 03, 2017 |
juliustip: I am tired of changing batteries every year(Used Mercury twice and some other deep cycle battery), is there any recommended 200AH battery that can go for 2 or 3 years straight? Would appreciate your suggestion.
NB: Am on off-grid 2kva and always switch off power at 12.2v i feel ur pain, batteries aren't cheap. to my view, i believe batteries just don't die without a fight, i believe batteries are constantly under-charged, you need to add more panels Also work on your loads or double your present battery bank to considerably extend their years of usage. Living off grid is a good thing. pls make sure you add more panel before acquiring new set of batteries. you will eventually smile. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 12:54pm On Feb 03, 2017 |
DMerciful: With current price(Fullriver @ 130K, Exide @ 200K, Mercury @ 115K etc) Lithium iron phosphate is cheaper in the medium term and far cheaper and super in the long term. It requires planning i see your point it is eventually cheaper and more efficient (Fullriver @ 130K, Exide @ 200K, Mercury @ 115K ) recession is not good ooo |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 10:26am On Feb 03, 2017 |
|
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 12:52am On Feb 03, 2017 |
Jean2: Interestingly, it is possible to use Solar power installation of less than 500WH for powering several equipment. Power cut (mains power outage) should not stop you from running your electronics... to be cont'd. Can it be true that the strength of home solar applications is directly d strength of batteries? My advocacy on AE has always been bedeviled with opinion that solar don't last and see no reason why they should fall in love with it as we do. We need to prove to Nigerians that solar works and works well & remains d lifeline of electricity to millions of homes. I salute the courage & works of great men here. It inspires millions to take their lives in their hands. |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 12:29am On Feb 03, 2017 |
DMerciful: The ariston has temperature setpoints adjustment and it can get quite hot if set high...but then sun gets really hot....as seen in solar electricity generation through heating of molten salt That solves it. It is a deliberate pre set. A valid point too Thanks |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 2:04pm On Feb 02, 2017 |
GeorgeD1: all, out of curiosity i decided to measure the max temperature of my solar water heater and do a comparison with a fully functioning electric water heater (ariston). the result was shocking even to me.
i knew the solar water heater really gets hot on a good day but i was really not prepared for the sharp difference in max temperatures between the two.
see below pictures:
the sun truly is the answer! Oga GeorgeD1 thank you for your innovative intuition the forum is getting too boring that is why i try to introduce issues on equalization of different batteries few days ago. i still find your discovery hard to believe, it's like a bitter pill. May be the ariston is on standby mode. pls fire it up untill the thermostat switches it off and re-run/test your values. am anxiously waiting to hear your results.  |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 4:03pm On Jan 29, 2017 |
Good day House can anyone tell me or link me with site showing standard days for equalization for SLA, FLA, AGM batteries i observed AE enthusiast set equalization to 28 days, some to 32 days. i set mine to 14 days or having BLS negates equalization of batteries ? am kind of confused. thanks !  |
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by efuro(m): 7:43pm On Jan 23, 2017 |
chris81964: We are officially a distributor and installer of Outback Power Inverters, Controller and Accessories. Inventory will be available in a few weeks. Good job. I always know you Don't compromise on quality. Keep it up. |