As long as they have the same nominal voltage, then yes, they can be connected in parallel. However, they will charge and discharge at different rates and one may carry the load more than the other one . There are some videos on YouTube https://www.youtube.com/watch?v=hqSc7FngRE8?si=C1Xtsu3qQL3IqAPW And https://www.youtube.com/watch?v=JcV6IIFqKt0?si=EEfCg_wVljZL7RH4 sharks776: |
durodee:I have finally resolved never ever to buy any inverter named by or produced by SOROTEC again! It is truly SORROW TEC(HNOLOGY)! Anytime I think of the inverter I cannot think of a SINGLE good thing about it. it is that subpar! First, the finish is far below the name. I strongly believe also that the self-consumption is higher than similarly sized inverters. I was not able to measure this though. The fan is noisy and the inverter failed woefully where Gennex and MUST inverters of similar capacity have thrived. Despite my misgivings, I paid 120k for the useless inverter to be repaired a few months back. I then relocated it for domestic use in my weekend house where I am completely off grid. I tend to visit the place every fortnight ( spending the weekend only) and put a total load of a small fridge, a 22-inch tv and six light bulbs on it. I made sure it was only INVERTING, no other task. Yet, the same error has resurfaced. I am not sure the bloody thing has worked for a total of 30 days before showing its true colours again!!! By the way, I live alone there before someone will say it was mis-used behind my back! |
durodee:Interesting to know I was here a few years back. Now I am solidly lithiumed! Total capacity at that site now 27kWh and no regrets. By the way, anybody in the house with a medium capacity inverter (4-5kw inverter) @24v?. Its needed to sort out a domestic issue. Kindly quote me here with your best price. Thanks |
Oshomo12:Saw that at a place I visited recently. The panel was part of panels connected in series in an high voltage setup ( close to 200 panels total in that installation). Due to some reasons( I don't know the full story) the instal had to be dismantled. This panel had a through and through meltdown!! |
And the panel died............
|
earthrealm:I just dey laugh since I read this. You know this battery issue is like marriage. You choose who you want and to you they are the best. All I know is that my oldest Lithium battery is more than 2 years now and life has never been this sweet since I started my renewable journey about 12 years ago. Over the years, I used both wet and sealed, semi-dry lead acid batteries, with the attendant up and downs. I also use domestically and for business, balancing the tug of MORE/ LATEST of an hobbyist and the PRAGMATISM of balancing the books in business had become an art for me. For learners and fresh, small sized users, there is no harm in going that route of lead acid first to learn the ropes BUT if you are planning on a 2kVA and above inverter system, the most reasonable and cost effective path is straight to Lithium. That is the only path that makes business sense in my experience. |
Interesting assumption. I don't know how you expect everyone to be on that list. Some of us are in rural areas without network connectivity or reliability. I generate about 25kwh averagely from one of my rural setups (24x 300w Canadian panels, 27kw LiFePO4 storage) daily (the biggest) and I have 4 setups in all. So the noise being made here is working, as it's encouraging us to do more ![]() AshipaEk0: |
jonescosmos:A perfect example of Power Room or Ile Agbara!!!!!! ![]() |
durodee:I appreciate all the suggestions. I decided to try a TV box and got one off Jumia @12k. Pictures attached. It was delivered yesterday and connected to my home WiFi network. Came with HDMI cable for TV connection. Has been working well. YouTube films played without any glitch or lag. Netflix is next.
|
Any suggestions on names/brands to consider? dollarnaira: |
Kai! Total knockout for plan 2 be that! dollarnaira: |
Good morning house, just want some advice here on Smart TVs. 1) Is there a way I can make my regular TV smart? I.e is there a box or stick readily available that I can attach? 2) Anybody with experience with Polystar 65inch smart TV. Is it worth the 300k price? Just to watch films and occasional football matches. Many thanks for your input! |
Successonpoint:You've done well OP. Kudos for your resilience and to your wife, she is a wife indeed. Far better person she is than some who have commented. Some advices: 1) Stay with your boss a while. Learn all he can teach you before leaving 2) Move far from him when you set up and don't go with his customers. Develop your own customer base 3) Keep a close relationship with him and work with him in getting big jobs. Contracts come easy if you have a network 4) Upgrade yourself in two ways. Go academic and a get a technical certificate in welding as a minimum. You can't get some contracts with your expertise alone. Also go online and learn, learn and learn 5) Determine which area of welding that pickle your interest and develop yourself in it. Aim that your name is the first that comes to people's mind when the think of that aspect 6) When success comes your way, remain fateful to your wife! Otherwise............. |
dacool1:Nothing lasts forever. Normal wear of the parts in motion is my thought. However,I have used inverter for 2-3 years straight atimes . Usually I plan towards @5years of use. After that, I am ok with anything that happens. I always look at it this way: how long can I expect to use a petrol generator 24/7 before changing the engine As long as the inverter lasts longer, I am ok |
Mine does, easily. For how long depends on your battery capacity. I have had one 1hp and another 1.5 HP for 3hours at a point. While it's not usual for the AC to be on most times, regular load is less than 2kva ( @1.5kw) but i have a 1.5hp water pump that on a timer of 15mins action every hour. The inverter handed that brilliantly. My usage of some other brands for the same activity showed that some brands advertised here are overated. Kaybthaniels: |
Kaybthaniels:I have used Gennex products for about 8years now. While I had only fair respect for their 3.4kva I bought then ( have had to send it in for repairs three times) , the 5kva I bought in 2021 have really been capable of getting the job done. Able to handle the loads well and easy to use and understand. No regrets in that area. |
bobmalu83:I want to clarify if you mean 3 pieces of 3phase machine rated 3kva each? Single phase inverters are cheaper than 3 phase ones. If I am to set this up I will rather go for 3 individual 48v 5kv-6kva inverters, each with a 7.2kw array of panels (minimum, preferably more) coupled with 15kw (48vx300amp) lithium battery bank. I will go for the high solar voltage CCs and possibly hybrid inverters to save costs. I will however parallel the batteries together, so that ,in case only one or two of the machines will be in use, then the other storage will not be idle. A fourth 3.5-5kva inverter will be for pump and light. It will have its own panels but I will likely connect to the same battery bank to just complete the circuit but relying more on harvest from its panels to meet the power need. As a minimum, a 7.5-10kva petrol gen should be available as backup, so that any of the water packaging machine could be switched over to generator if the need arises. You can do your own initial assessment and calculations This schematic might look strange but using solar/inverter for industrial use for years made me realize that a single 20kva inverter is like putting all my eggs in one basket. |
Yorubahdguy:How many solar panels please? |
ewizard1:You've hit the nail on the head! |
My guy cool down. You have bought already, mistake or no mistake, time will tell and you would have learnt from it. Nobody in this forum was born with super knowledge and don't let anybody make you feel you have killed someone. We all learnt one way or the other. We all have our failures in this solar journey- trust me, even the gurus here have wetted their pants before. Use your panels and CC. It will serve , no matter how small You have osayuwamwen: |
I recently had an inverter that stopped working less than 3 months of purchase. Next i was slammed with a bill of 120k for repairs. Reason: the components inside failed, hence it's not covered . This then begs the question of what exactly is covered ?mctfopt: |
manya:Let us assume 700 watts usage @12v = @60 amps. Is your 10hours usage going to be at night only? If so all the 60amps must come from your battery. You will need about 70- 100amps battery if lithium, or as 150amps if lead acid to ensure about 50%DOD. The rest is your choice and pocket. By the way, nothing says you cannot use car battery meanwhile before you gather your self for a good deep cycle battery. |
Battery type is not the first problem here. There is harvest versus usage disparity. Your panels will generate @ 600w/day under the best conditions. Yet you plan to use 500-700w/day. Chances are that the days in a year that you will meet your 10hours need will be few unless you change your calculations or expectations. manya: |
Hmmm. Sorotec. I have a 5.5kw unit (bought late last year) acting up. Displaying error 32. Manual says it's a communication failure between inverter and remote display. It will not connect to battery and when switched on by solar imput, will temporary display no battery mode before bringing out the error. I had to put back my backup 5kw Gennex while waiting for the resolution. My battery is 12kwh LiFePo4 and connected to the battery through positive and negative power cables only. |
ojesymsym:I beg to disagree. One day , at my business, the 5kva inverter kept tripping with overload fault showing. This was an inverter that had no issues with 1.5HP submersible pump and an 1HP AC together on a normal day. I will switch it back on, check the load (@700w) observe for a while, get back to my office and about 10mins later it will trip again. Out of frustration,i went to the DB and I started isolating the building, section by section until we found one area that anytime we switch it on, then the inverter trips. I then called my electrician who came, checked , and could not find the problem. Soon the same issues resurfaced somewhere else . So we searched socket by socket only to discover a useless phone charger was the culprit. One of my staff, oblivious to my dilemma, wanted to charge her phone . She will plug it, power will go, she will remove the charger use her phone awhile then plug it again when power comes. When i isolated a section of the building, she jejely moved to another part of the building to charge her phone . That day was not funny. I made sure i destroyed that charger that day before someone go give me heart attack |
luvlyoracle:The only potential problem is not the frequency. The capacity too. The capacity of that generator (1.0-1.1kw) to effectively power and charge through a 1.5kva is suspect. Charging puts additional burden on the generator and putting a stabilizer on it cannot correct that. |
Merry Christmas house, may the new coming year harbour better climes for RE. Clear sky's, brief heavy non-windy rains to keep the panels bright and clean, less static electricity etc etc And money enough to meet our needs and sane government in place! All in all , MERRY CHRISTMAS ONCE AGAIN!!!! |
And you equalize monthly? vta2008: |
Thinking back, I think my experience may have been affected by the capacity of the inbuilt CC which was 60amps. 60amps at 48v will only give about half the capacity of a 5kva inverter and about full capacity for a 3kva inverter. I however tested with 5kva inverters I will expect the inverter to remain on in the scenario you cited provided yield was sustained during the period of the surge demand. TechGeek777: |
Comment on "batteryless" inverters from direct use. They cannot function at full capacity without batteries irrespective of the panels yield. Also while in that mode, any surge demand ( fridge etc) may trip off the inverter. Also be ready for intermittent trips from cloud cover etc as it can only address present demand from solar yield. I ended up reserving that mode for emergencies only. TechGeek777: |
The simple answer is YES. How to connect it (2S = two in series etc) was what bigrovar was trying to explain. drizzypat: |
isangjohnson:Yes to the question. Also note that there is a reason National grid transmits long distances using HIGH voltage: there is less energy loss and also affording the use of thinner wires as the case may be. So I have a basic principle with high voltage hybrid inverters. I will ramp up the voltage as high as I can first before thinking of parallel setup. Just be careful you don't break the voltage ceiling. If you break the amp ceiling, the Cc will just cap it at its capacity and continue working. If you break the voltage ceiling, then................ In extremely maxing out the capacity of equipment just remember that most times, the benefits does not always outweigh the risks. |