drvalency: when can we begin?
Can i chat you via WhatsApp through the numbers on your signature? You can chat me |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 12:24pm On Dec 12, 2021 |
drvalency: Hi. I want to learn how to do a professional estimation and costing in electrical wiring and installations.
How much will it cost me to learn it from you?
Awaits your response. No problem but will prefer zoom training |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 12:06pm On Dec 12, 2021 |
KolaShangOne: 4mm Is widely used for cooker.. I think it can handle it, right? Yes it will , and these days people don't use electric cooker for long cooking like that because of power consumption |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 8:06pm On Dec 11, 2021 |
Ibk2020: Pls who can explain how we can pre-install kitchen heat extractor ventilator pipe?
No videos on YouTube for this Extractor fan or cooker hood ? If it is kitchen extractor fan, there different sizes but the common one for tye kitchen is 6inch or 9inch Procedure ; -If you are installing 6inch, get a short piece of 6incj PVC, -Bury it to the wall facing the outside or fence to allow the extracting the heat outside. -Let your electrician run a conduit to the pipe for electrical connection, you can allow the extractor running if your light is on by looping it to the nearest point if light or create a separate a gang switch to control it . -After screening you can now I stall your extractor fan. Same procedure for 9inch but instead of using 6inch pipe , you will get a carpenter to make square box of 300mmx300mm Then follow the other procedure above |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 6:15pm On Dec 11, 2021 |
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 3:22pm On Dec 11, 2021 |
Always at your service |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 8:25pm On Dec 10, 2021 |
rmx: Can’t import everything nah , buy stuffs locally too . Especially If I get good deals
Doing some calculations on the Ac , might buy locally
Also just concluded on pop boards locally thru an importer introduced by next
Must encourage local businesses too  Ooh okay sir, are you going for media AC sir , Maybe you need to visit their office at Ojota in Lagos for good deal .. |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 6:00pm On Dec 10, 2021 |
Call us today for your electrical installation
|
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 5:42pm On Dec 10, 2021 |
We are ready to deliver your goods
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 5:38pm On Dec 10, 2021 |
We are available
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 5:26pm On Dec 10, 2021 |
Our installation is second to none
|
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 5:00pm On Dec 10, 2021 |
rmx: You dint market this to me sha , why 
Placed order for importation , but you never can tell Sir, don't know you will buy light locally. This light is different from most of the china in the market. I have 2 of the 12W in my kitchen since 6years ago and It can withstand low voltage. |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 3:01pm On Dec 10, 2021 |
On going Conceal WC installation
|
Properties › Re: ABB Distribution Board And Schneider Distribution Board Our Choice by topsy23(op): 2:49pm On Dec 10, 2021 |
Call for your DB |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 12:21pm On Dec 10, 2021 |
Quality LED recessed light LIPER product made in Germany
Call and place order. 3-5years guaranty
|
Properties › Re: Nigerchin, Kabelmetal And Coleman Cables, by topsy23(op): 11:34am On Dec 10, 2021 |
Call us today |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 9:15am On Dec 10, 2021 |
Talkwisdom: will sure get back to you.
thanks Alright sir |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 9:13am On Dec 10, 2021 |
bayo2018: He said he’s using 2.5mm for socket ,AC,cooker,water heater
And that the load will be direct and the circuit will be 30Amps and it’s standing on its own sir.
And also he said that it is Full conduit pipe that’s being laid there that’s the reason the cable are much sir. The electrician is not getting it right . Protecting an appliance with 32A with wrong size of cable...hmmm each cable has their own current carrying capacity and each breaker has their own protective current as well Using 30A to protect AC it means if there is fault current somewhere and your breaker suppose to trip off, it won't and the next thing is to melt the cable since the breaker refuse to trip. |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 9:07am On Dec 10, 2021 |
bayo2018: He said he’s using 2.5mm for socket ,AC,cooker,water heater
And that the load will be direct and the circuit will be 30Amps and it’s standing on its own sir.
And also he said that it is Full conduit pipe that’s being laid there that’s the reason the cable are much sir. Don't allow road side electrician to give you wrong information . The rating of circuit breaker(MCB) or starblock as normally called by this road side technicians for each of the appliances are as follow: -10A MCB is for lighting -20A MCB is for AC(direct from DB to AC switch) -20A MCB is water heater (direct from DB to water heater switch) -30A MCB or 32A MCB is for socket( you can loop 5 or 6 socket to one MCB -32A/45A MCB is for cooker control unit. |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 8:23am On Dec 10, 2021 |
bayo2018: He said Coleman brand sir I’m thinking of cutix because I read here that it’s the best cable to use And he said 2.5mm for the AC. If you are in East cutix is okay . 2.5mm cable for AC? IEE standard says 4mm. Below are the recommended cable sizes for appliance by IEE regulation 1.5mm is lighting lighting 2.5mm is for socket 4mm is for AC and water heater 6mm is for cooker |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 12:36pm On Dec 09, 2021 |
Aforxzy: Our on going project. Almost completed.. Love this type of flat roof with the ceiling design |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 12:21pm On Dec 09, 2021 |
Talkwisdom: Please send to learnersng@gmail.com. please if you can include total labour cost, i will be grateful Mail sent sir |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 8:32pm On Dec 08, 2021 |
Our installation is to IEE standard
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 8:30pm On Dec 08, 2021 |
Installation of cable trays, isolator for outdoor AC for VRF system
|
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 10:51am On Dec 08, 2021 |
Talkwisdom: hello topsy23, I like your thread. how much will it cost to wire 8-bedroom flats with two bedrooms ,parlour, dinning and kitchen each for the 8- flats. just electrical wiring and TV points in all these flats. from quantitiy of pvc pipes,all conduit materials to be used and quantity of cables required. all conduits
Thank you in advance. Good morning sir, I will do a comprehensive bill of quantity . But where can I send it to ? |
Properties › Re: Re: What Size Of Plumbing Pipes Are Use For Residential Buildings by topsy23(m): 10:11am On Dec 08, 2021 |
Yanucar: Hello everyone, what to do if a pipe suddenly bursts and it leaks heavily? After all, while the plumber arrives, the apartment can be completely flooded. Try to lock all the valves to prevent inflow of water to the building |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 11:25am On Dec 06, 2021 |
rotecch77: New week quote”
When a customer complains, he is doing you a special favor; he is giving you another chance to serve him to his satisfaction. You will appreciate the importance of this opportunity when you consider that the customer’s alternative option was to desert you for a competitor.” Great quote |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 8:11pm On Dec 05, 2021 |
Amadikwa100: Hello,please how much will it cost to wire a 5 bedroom duplex For a standard 5 bedroom duplex with 2 number distribution boards below are the quantity of cables needed 1.5mm Red. 8 Black 7 Green 2 2.5mm for socket and water heater Red 5 Black 5 1.5mm Green 4mm for AC, cooker unit Red 3 Black 3, 2.5mm green 3 10mm for a 3-phase supply Red 2 If you have solar inverter DB 6mm 3-core flexible cable 70m |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 7:51pm On Dec 05, 2021*. Modified: 9:43am On Dec 06, 2021 |
Abudu2000: once one gets lucky to meet a client who understand quality jobs are expensive, na davido joliment  Na soo |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 5:39pm On Dec 05, 2021 |
Abudu2000: did a design for a client there since 3months ago, till now i never chop the money finish  That's a good client. |
Properties › Re: Contact Us For Your Electrical/mechanical(Plumbing) Design And Installation by topsy23(op): 3:55pm On Dec 05, 2021 |
Amadikwa100: Hello,please how much will it cost to wire a 5 bedroom duplex Good evening sir. Can you send me the plan so that I can send you breakdown. WhatsApp number 08033643191 |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by topsy23(m): 2:02pm On Dec 05, 2021 |
kopell: Imagine 200 million for land and we are still talking about generator, what a shame. What of banana island .700-850million naira |