Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 1:38pm On Oct 15, 2016
OK informative enuf but how many times do u open this breaker? Once a yr? Once in two years? We need to innovate. smiley
mank1234:
The difference is majorly at the point of extinguishing the arc formed during closing and opening of the contact. With AC, the arc is of short duration since the current changes direction 50 times per second. In DC, current does not changes direction so the arc is longer. If you use AC in place of DC,as the components is not made to eextinguished long duration electric arc.

Arc in layman language is the fire or spark you see when you touch two wires together. It also happens inside the breaker but you won't notice it because it's immediately extinguished.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m):
U can use clamp to link the two breaker lever or use solid glue and a bar to link them together. Sincerely, I don't see anything between AC n DC breaker unless someone educate me. For now I use AC breakers n no lele grin
mank1234:
The link posted is for ac breaker. I actually have 2 DC circuit breakers, each is double pole with one terminal marked +ve the other terminal -ve. One is 32A, the other 63A. Was wondering if there's a way of linking the two to trip at the same time.

I'm using the 32A between solar and CC, 63A between battery and CC. From previous warnings, it's possible for the 63A to trip and destroy the CC. So I'm wondering if the two breakers can be made to trip simultaneously if there's fault.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 12:47pm On Oct 15, 2016
Whatsapp me....don't want to interfere with people's business grin
Monlo:
@Dmerciful,how much did u acquire this meter.I think i may need one to combine with my Epsolar mppt CC,so i can be seeing the input/output parameter at the same time.Tnks
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 12:45pm On Oct 15, 2016
I understand but how does the breaker differs apart from name? What happens if you use AC breakers for DC applications?
kiekie1:
DC circuit breaker, like their name suggests, is used for the protection of electrical devices that operate with direct current. The main difference between direct current and alternating current is that in DC the voltage output is constant, while in AC it cycles several times per second. smiley
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 11:40am On Oct 15, 2016
Would you be kind enuf to tell us the difference?
kiekie1:
Majority of 2 pole breakers are AC ... You can actually improvise by using ² DC breakers of same amperages.. Thanks !!
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 11:32am On Oct 15, 2016
Wish these clouds could disappear...affecting my harvest grin grin grin

Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 8:18am On Oct 15, 2016
They are available on aliexpress.com...just search for two pole breakers. You van also get multiple
https://www.aliexpress.com/item/FZ47LE-63-C63-AC-400V-63A-Two-Pole-On-Off-Switch-Mini-Circuit-Breaker-4000A/32332213418.html?spm=2114.01010208.3.102.4oxvv9&ws_ab_test=searchweb0_0,searchweb201602_4_10065_10056_10068_10055_10054_10069_10059_10078_10079_10073_10017_10080_10070_10082_10081_421_420_10060_10061_10052_10062_10053_10050_10051,searchweb201603_7&btsid=23ee2156-1dc8-431f-ad38-7efa937ad056
mank1234:
Thanks. How can I get the mechanical connector. I want to tie 2 2-pole circuit breaker together?
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 8:14am On Oct 15, 2016
I have seen up to 3 pole breaker. CC to battery on one breaker(one cable only preferable +ve) while PV to CC on the other breaker also one line only preferably the +ve. If one line in a two line circuit is disconnected, its enough to open d circuit
battleaxe:
Double pole breakers can be bought as is off the shelf. Not a regular item on the corner shop but you should be able to get if you ask around, maybe they buy it specially from you.

Dmerciful,
So if PV and battery are connected to either side of the DP breaker, where does the CC fit in? Thanks.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 6:17am On Oct 15, 2016
Double pole breakers are basically 2 breakers mechanically connected so they trip same time. So if one line of the PV circuit and one line of the battery circuit is connected to each breaker, they trip same time.
mank1234:
Please upload picture of an example of double pole breaker? I've been looking for it since and I'm confused if a DC breaker with +ve and -ve pole can be used in place by making positive pole for battery to inverter connection, negative pole for cc to solar array.

Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 6:41pm On Oct 14, 2016
Upgraded my panels from 750W to 1000W.....gradually I'm getting there. Green for life cheesy cheesy cheesy cheesy

Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 6:39pm On Oct 14, 2016
Learnt something now...double pole breakers ensures the PV and battery are disconnected simultaneously thus avoiding d risk I mentioned earlier which is battery side tripping and PV side still energised. This makes more sense.
GeorgeD1:
guys,

just a page from the morningstar mppt 60 manual:
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 12:10pm On Oct 13, 2016
You can install a surge protector just after the breaker btw the PV and CC. Depending on the height of ur installation u might install a lightning arester
azz19:
kindly help comment on this.
cc:kiekie1
battleaxe
Dmerciful
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 9:52am On Oct 13, 2016
Thanks...we are all learning. Green for life grin
dicksonadams:
I have e great respect for Dmerciful the guy Na scholar grin
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 9:50am On Oct 13, 2016
It could trip due to faulty breaker, someone can go there when you're not around. You urself can trip it mistakenly. The breaker btw CC and battery in reality offers no protection but risk!
The reason is that most of these CC are MOSFET powered and MOSFET have low tolerance of static charge. If the breaker for any reason trips and sunlight is present, there in no negative that would have acted as sink or path way for the voltage being generated. Same thing applies to some inverter, if a breaker must be installed it should have a pretty high amp rating so it doesn't trip when there is mains....your power MOSFET may fry
battleaxe:
Why would it trip during a sunny time as you mentioned above?

I'm assuming it's because of an increased production I.e. Current at that point in time.

If your breaker is correctly sized at or above the rated capacity of your CC; why would you not want it to trip when it's seeing more current than its rated for?

That's its job! Again, if properly sized, the benefits to having a breaker there outweigh the possible risks to not having it there.

We sometimes may never be able to comprehend what damage those 6k items save us from!

N.B.: Note taken that if you have a breaker between your PV and combiner, it possibly should have tripped already based on your scenario above so CC should be all safe.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 10:47pm On Oct 12, 2016
I still strongly recommend that the only breaker is btw the PV and the CC. Btw CC and battery should be straight connection. The risk is negligible but if you decide to introduce a breaker btw CC and battery thereby creating a new higher risk, don't blame anybody if for any reason it trios during sunny time cos ur CC will be damaged.
mank1234:
What should the breaker capacity be for a 1300W solar array, 24V system (CC is rated at 60A)?
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 10:41pm On Oct 12, 2016
What does the manual says about resetting the CC? The CC has inbuilt protection and from the battery to CC what surge could possible spring up? If the CC short circuited that means its already bad n the internal fuse will break. Its not in every case circuit breaker protects
mank1234:
He used the breaker as a disconnect switch between CC and battery, which also served for resetting the cc. In the absence of this, what hardware do you recommend that will do both and also avoid nuisance trip?
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 10:37pm On Oct 12, 2016
Why will the CC short circuit?'its an advance technology remember! Its has inbuilt protection
bigrovar:
The CC short circuiting?
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 7:21pm On Oct 12, 2016
Enlighten me of the risk cos I don't see what can cause a risk from CC to battery.
battleaxe:
.... Still...,
The benefits outweigh the risks/exposure in my opinion.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 3:20pm On Oct 12, 2016
The inadvertent trip I meant is if someone or you mistakenly trip it during the day then its similar to installing ur solar panels first to ur CC before installing ur batteries n the CC will positively fail.
battleaxe:
@Dmerciful,
Apologies for the Hmmnning.

I have read a few manuals and I have never come across a manufacturer advice not to install any electrical protection between CC and battery. On the contrary, all of them recommended this.

Secondly, while electrical protection offers you the added protection for your equipment in case of faults, it primarily also should be to protect you against fires resulting from overheating of your cables.

I would think that whatever fault you have downstream of your CC (I.e. Between your CC and battery) which causes your breaker to trip, is such that if you did not have that breaker there, would have wrecked further damage upstream to your CC and above.

I would rather have a tripped breaker with possible minor damage to CC electronic circuitry, than to have significant upstream damage or fire.

I'm open to rebuttals on the above!
Investment › Re: Treasury Bills In Nigeria by DMerciful(m): 2:06pm On Oct 12, 2016
TBills is far better than fixed deposits...infact comparing TB with fixed deposit is like comparing CNN with NTA grin
LaconicINC:
Here is something I also understood, please gurus in the house correct me if I am wrong, lets say I made a bid for 100,000 naira 13% 91 days tenor and it was successful, my interest will be 13,000 roughly, divide that my 3 months that gives me approximately #4,333.33 per month. compared this to fixed deposits, that gives you maximum of 10% per annum, I think T bills is far better. Am still learning sha, maybe am wrong. I just sent Stanbic a mail requesting the form and they just did, lemme fill and send back, I will keep us updated.
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 8:06pm On Oct 11, 2016
Thanks for looking out for me....but i will like to the error I made grin
GeorgeD1:
saipro & battleaxe,
you guys could just correct the error without humming and humming.
i'm sure dmerciful doesn't realize his mistake and seems it really is a honest one.
afterall, we all learn everyday. smiley
Satellite TV Technology › Re: Solar Energy, A Complement To FTA by DMerciful(m): 11:04pm On Oct 10, 2016
Super yes! grin its the surest way to damage ur CC. Infact never install a breaker between the CC and battery cos any inadvertent trip fries your CC grin. Happened to a friend recently.
mank1234:
A friend's morningstar ts-mppt-60 solar controller got damaged. He suppects that the damage might have been caused by accidental disconnection of battery power to the CC before the disconnection of the solar input.

His solar setup Voc is around 90V and his battery bank is 24V. Does a disconnect of battery before disconnecting solar damage morningstar mppt charge controller?
Sports › Re: West Ham Presents Jersey To Igwe Of Nnewi In Anambra by DMerciful(m): 8:33pm On Oct 08, 2016
If na in those days that jersey might equal to one slave grin grin grin
Politics › Re: Why Are My Igbo Brothers And Sisters Shamelessly Defending Corruption? by DMerciful(m): 7:54pm On Oct 08, 2016
Bubu is a fraud. Abacha did not steal-Bubu
Politics › Re: NBA Demands Release Of Detained Supreme Court Justices by DMerciful(m): 6:36pm On Oct 08, 2016
is DSS now into financial crimes? yeye dey smell undecided
doctokwus:
Raids are carried out by security agencies against judges,even in saner climes when evidence or even a whiff of corruption is found against even just a single judge,talkless of where the entire institution here has been corrupted.
Infact,sometimes even the security agencies pose as undercover agents and if a judge is recorded to as so much willing to accept a bribe or serve as a go between for any other judge,without even actually taking it,its a serious offence for which he/she is charged and prosecuted by d state.That is how highly demanding the integrity of judges in saner climes are.
What NBA shud ask for is speedy charging of the judges to court,not insisting that the security agencies cannot carry out their duties.They shud also voice out against any selectiveness,which is the hallmark of this govt.
A corrupt judge is a threat to national security,as evidenced in the happenings in Rivers state,so DSS is well within it's core mandate of protecting national security.
Politics › Re: NBA Demands Release Of Detained Supreme Court Justices by DMerciful(m): 6:32pm On Oct 08, 2016
the security agency like the police enforce the law after it has been interpreted by the judiciary. everybody is innocent until the judiciary says otherwise. everybody needs to study government till final yr...too many political illiterates in Naija
SuperS1Panther:
If you are corrupt and it has been well established, i careless about one stup1d warrant. When he was being corrupt, he did not need any warrant to be and when he is being arrested for his crime too, warrant is not required.
Politics › Re: Ogun LG Elections: Amosun And Wife Vote (Photos) by DMerciful(m): 6:06pm On Oct 08, 2016
Akintola in the making,loool
Politics › Re: Why We Arrested High Ranking Judges – DSS by DMerciful(m): 5:13pm On Oct 08, 2016
so u believe DSS even after being in this country since buhari came in? you nor try at all
Charly68:
I think we must face the reality here,whether executive ,judiciary or legislature,everybody must be under the rule of law. . The security has write to search anywhere but they must go there with their search warrant . Imagine the huge sum collected from the rogues ! Where for Christ's sake did they get over 93m naira excluding other foreign currency in the house . Not in their bank accounts for God's sake what type of businesses were they doing to get such a sum at home ? We must face the reality here. Until judges begin to go to jail,the mess in the judiciary won't stop. That place is the only hope for a common man who seek for justice.
Politics › Re: Why We Arrested High Ranking Judges – DSS by DMerciful(m): 5:07pm On Oct 08, 2016
Thats how you guys gave Buhari this false belief he can do anything until he dared the militants and he is looking to negotiate. everything is not force if not US would have attacked north korea and watch the korean penisula n los angeles dissolved by N.Korea
CecyAdrian:
Immunity does not give him the right to commit a federal offense that's if you even realize the gravity of what he did.
Politics › Re: Why We Arrested High Ranking Judges – DSS by DMerciful(m): 5:04pm On Oct 08, 2016
So u want DSS to have absolute power to do as they like? y are you being emotional like a kid?
seXytOhbAd:
I am always amused by the stupidity displayed by anti government nairalanders, especially TB. Let us all use our senses please. Our judiciary system is totally corrupt, to the point where a judge stupidly gave a judgement on frivolous grounds recently. Now you expect the DSS to get a warrant? Lmao. From where will they get it? Isn't it another judge who will sign it?And same judge will probably call his fellow man to give him a heads up. Please let us be growing up and using common sense. Judges are virtually untouchable in this great country, and we all know they are living lifestyles they cannot justify (notice my play on words?).

God bless Nigeria
God bless Nairaland
God bless the DSS cuz as they have fu¢ked with the judiciary now, they will have to go the extra mile in actually ensuring that their cases are airtight
God bless EFCC, always arresting and jailing yahoo boys, but failing to jail our kwarrupt leaders.
Finally God bless TB. You know who you are. God will give you some sense one day
Politics › Re: Why We Arrested High Ranking Judges – DSS by DMerciful(m): 5:02pm On Oct 08, 2016
you do not know how things work. a governor on a plater? undecided
CecyAdrian:
Because he knows what is at stake. That judge goes down, it will only take some months for Wike to go down with a loud thud. So many dumb brains commenting on this forum without reasoning are clapping and hailing him.

I just pity him. He just handed himself on a platter of gold to the vultures
Politics › Re: Why We Arrested High Ranking Judges – DSS by DMerciful(m): 4:58pm On Oct 08, 2016
You dont want rule of law again? grin. why did we return to democracy then? pls control ur emotion...contries are not run with emotions undecided
CecyAdrian:
Barca, warrant or no warrant, they are all guilty and should be rounded up in anyway possible. The same law has put us in this mess, it's high time FG wave it aside and do some necessary things.

1 2 3 4 5 6 7 8 ... 791 792 793 794 795 796 797 798 799 (of 827 pages)