PropertiesRe: General Topic Thread-To Discuss Anything And Everything in Building Construction by 44chux(m):
KolaShangOne:
Funny thing is that the Venturi principle tends to indicate that there is a reduced pressure at the intersection accompanied by a higher fluid velocity. So when water gushes out, it's more of a reduced pressure, high velocity than increased pressure, increased velocity. The Venturi principle is what the technique of reducing Cross-sectional area to improve flow is based on.

This will bring the question "are you saying pressure is inversely proportional to velocity?.
Yes (absolutely). The desired increased pressure is just to create a larger pd during flow which increases velocity. Static pressure is the equalised pressure in the system when no flow occurs (velocity=0). flow occurs, coz of a pressure drop across the pressurised tap and the unpressurised part discharging to the environment. According to bernoulli the pd is proportional to velocity head which is the flow we see. The venturri effect upstream adds RAM

(UPDATE:The best would be to run a bigger pipe into a manifold header with buffer e.g. 6" diameter 1meter long pipe @ house entry point for onward distribution. This would eliminate a lot of frictional loses that occur on the walls of the pipe during flow. The next best/most economical would be running something like 2" feeder line from tank to house entry point then reducing it b4 delivery to various consumers. This gives you all the other benefit at the least cost)
PropertiesRe: Aluminium or Stone coated Tiles? Things you should know before you roof ur house by 44chux(m): 8:11pm On Jul 25, 2016
KolaShangOne:
It used to be 2821, if you're buying over 200sqm,its 2677.. But then because of this Naira / dollar issue, new prices are released every week

Naira was 290 on Thursday, 24hrs later, it's 379.
Thanks

What is it with Wichtech? Nobody seems to remember then when it comes to roofing and plumbing. Any particular reason?
PropertiesRe: General Topic Thread-To Discuss Anything And Everything in Building Construction by 44chux(m): 10:21am On Jul 25, 2016
earthrealm:
the present discussion on water pressure issues on duplexes is an interesting topic, in my residence, the tan k is diecly placed on the roof, water pressures to the shower heads is inadequate, the LL installed 1 of those pressure pumps after much complaint from the residents, and it somewhat remedied the problem...albeit not satisfactorily....presently there is what i suspect to be internal leakage, as water is dripping from 1 of the walls outside.....also the main tap outside, once that one is turned on...water supply ceases totally on the first floor of the duplex

going forward, am about commencing my own build, also a duplex, and am worried about how to prevent such an issue from my build.
i also would prefer having the water tan k on the roof...if i can, the 2nd option am considering is making the security houise a 1 storey build and placing the water tan k there.

some plumber said the present practise of first dropping the supply from the tank to the ground first before sending it up again is wrong, that he prefers running the water supplypipes up in the ceiling/last blocks on the roof...and the dropping them down to the shower heads/water taps...ie the bathrooms....
has anyone tried this....what are the pros and cons?

also mny people recommended using 1 '' pipes to serve as supply from the overhead tank, am thinking 2'' should even work better is creating the differential needed for adequate flow,... am i right in this assumption?
i detest those pressure pumps, and i would want to totally avoid it in my build.

nice thread btw, hv been on ghost mode for a while
Sometime back on this thread we tried to discourage Agarawu from placing the tank on top of a building for good reason. You can read up on that. But if you must, then the top of the tank has to be on same level with the roof kingpost which would make the tank conspicuous.

Regarding your plumber's recommendations, I think it wouldn't be visually appealing, (same reason people dropdown and tunnel the utility power lines from the last pole via underground to their meter). Also rain will want to follow the piping to ur wall/ceiling. (Assuming the tank is not on top of the building. )

As per piping going down then up again, as long as you have minimum (ie 2, max 3) elbows, the drop will be insignificant

Finally by using 2" supply (feeder) line then reducing it closer to the consumer you create a venturri effect which improves flow
PropertiesRe: General Topic Thread-To Discuss Anything And Everything in Building Construction by 44chux(m): 11:18pm On Jul 24, 2016
abdulwastecx:
You just made remembered pipe network analysis.
Water demand is not a factor that reduce pressure head. Water demand will affect your storage capacity
Max water demand is the single greatest factor considered in pipe design (as well as in almost every other application sizing, the max demand is given the greatest consideration) .
Check Darcy–Weisbach equation.
Infact Serghide Explicit Equation or the Swamee-Jan equations is used in determining optimal (cost/benefit) pipe diameter for max flowrate to prevent excessive pd.
PropertiesRe: General Topic Thread-To Discuss Anything And Everything in Building Construction by 44chux(m): 5:46pm On Jul 24, 2016
EgunMogaji:
Ibi ayo lati ma ma ba oruko wa grin

I just finished my lintel using previously used wood that the carpenter supplied. That has proven to be the one single biggest mistake of my build. The money saved has now diminished in my eyes and any saving will be used up in extra plastering and chiping to make it work.

Now I know that your question was on decking and mine example was lintel work.

May god continue to bless all of our hustles.
The planks are of different types. The more expensive hard wood types (around NGN1,500/14ft)can be reused upto 5x while the cheap soft wood types (NGN1,000/14ft) can't coz the elements (sun & rain) destroys them rapidly. In fact I left this type in the open for just 2weeks b4 sheltering them for another 9week only to discover at the end that they were practically useless.
PropertiesRe: General Topic Thread-To Discuss Anything And Everything in Building Construction by 44chux(m): 4:53pm On Jul 24, 2016
battleaxe:
Just regular PVC pipes.

@Kola, you're right. It's 1 inch.

The height of the tank would not make a difference in this case since the plumber still dropped the feeder pipe to the bottom before distributing.

I still need ideas from people who don't have this issue in their builds- how did you resolve it?
Raising the tank stand height will make a load of difference by increasing the hydrostatic pressure available. Also increasing the diameter of the supply (feeder) line from the overhead tank to the house, then reducing just before it enters the house might help.
Also confirm if the difference in the pressure from the shower and from the wash hand bowl at the same floor is significant ie if the hand wash flows with good enough pressure.
PropertiesRe: WATCH THIS SPACE (Electrical Showcase & Review) by 44chux(m): 10:01pm On Jul 21, 2016
PropertiesRe: General Topic Thread-To Discuss Anything And Everything in Building Construction by 44chux(m): 5:39pm On Jul 21, 2016
mufutau55:
LOL!! My brother... na shakara jare. Where I go leave all these nice people go? "Edo Airways" nah to raise one leg, close eyes and land for oyibo land o.

Hajji M.
Whether na by Aircraft, Spacecraft or Witchcraft, flying na flying.

But me think he been wan say "Benin Airways" b4.
PropertiesRe: WATCH THIS SPACE (Electrical Showcase & Review) by 44chux(m): 5:07pm On Jul 21, 2016
allCopacetic:
Light Affairs
Which type are these
PropertiesRe: Aluminium or Stone coated Tiles? Things you should know before you roof ur house by 44chux(m):
KolaShangOne:
At Tower Aluminum factory
What's their current price for 0.55 metcoppo.
PropertiesRe: General Topic Thread-To Discuss Anything And Everything in Building Construction by 44chux(m): 8:58am On Jul 21, 2016
erico2k2:
Good luck at that, I do not envy you guys living in that part of the country
I school at Enugu ESUTH,the way that ground strong eh, any involving earth moving na major stress.Even our Timberlands hear am grin grin grin
Been to a part of Imo State where women beg for ur permission to dig out the boulders, after which they use hammer to manually crush it to size and sell it to crushed stone suppliers.
PropertiesRe: General Topic Thread-To Discuss Anything And Everything in Building Construction by 44chux(m): 12:24am On Jul 19, 2016
mufutau55:
The thing is that, I have long opened a fight thread and broadcasted here but nobody cares for it... except here where everyone is supposed to be learning. I will soon disappeared from Nairaland as whole anyway.

Hajji M.
Baba pls don't do that without handing over the barton. if you must, pls let me know so I will create a new moniker: "mufutau56" and continue in ur footsteps.
grin
PropertiesRe: General Topic Thread-To Discuss Anything And Everything in Building Construction by 44chux(m): 12:10am On Jul 19, 2016
EgunMogaji:
grin

There's no need for a step-down actually.

Since it's solar (sorry I didn't specify that initially) the inverter just needs to supply 110 to a whole house surge protector and then to the breaker box.
https://www.amazon.com/gp/aw/d/B00SIRD4I2/ref=pd_aw_sim_sbs_504_1?ie=UTF8&dpID=51t2qbdSC2L&dpSrc=sims&preST=_AC_UL100_SR100%2C97_&psc=1&refRID=EZW314QTYTXJR0J30568

Update: just wanted to show there are still split phase inverters. You won't appreciate this flexibility until a friend/relation brings you an expensive toy that can't be used until... coz itz 220v
PropertiesRe: General Topic Thread-To Discuss Anything And Everything in Building Construction by 44chux(m): 12:03am On Jul 19, 2016
3strikes:
Egun I dont see why this is not doable. Can one place the stepdown/ converter by the change over / Nepa room....so that way the voltage conversion is first done by converting 240v from the pole to the 120v needed in the house?




grin grin grin
It might be more efficient if he draws/connects to the public 11kv and steps it down to 110v. Although the utility comp will change a higher tarrif(industrial tarrif), but your power will be more available and stable enough to run sensitive equipment
PropertiesRe: General Topic Thread-To Discuss Anything And Everything in Building Construction by 44chux(m): 11:40pm On Jul 18, 2016
n3xt:
That's good to know. Can you be of assistance with the information required? I need current price of building materials for a multi-Dwelling project in that location.

Thanks bro.
Am disappointed. Is NTA RD. Mgbuoba, now within 20km radius of H52

brabus:
Sorry about that. I can imagine the cost of keeping your men on site without doing any work. Travel cost and the risks. I've been there before and I've placed a caveat on it. For now, my job is only limited to areas within 20km radius from H52.

Wishing you all the best!
PropertiesRe: General Topic Thread-To Discuss Anything And Everything in Building Construction by 44chux(m): 11:24pm On Jul 18, 2016
EgunMogaji:
Oh I have that part covered.

I'm looking for day to day life experience living with 110 in a 220 country.
Some corporate buildings in 9ja use the 110/220V split phase connection. There are wall sockets that have both and u can choose 110/220 by either horizontal/vertical positioning.

It will offer you flexibility
PhonesRe: Poor Samsung Mobile's Warranty Service by 44chux(op): 9:14pm On Jul 18, 2016
July 18th, yet to collect the phone till now. Always one story or another.

I wonder what I'll do with phone if I eventually collect it.
PropertiesRe: Best Of Price On Tiles,water Closet,pipes And Fitting Free Home Delivery by 44chux(m): 10:14pm On Jul 14, 2016
CrimeRe: Man Slaps Wife To Death In Owerri, Imo (picture) by 44chux(m): 3:12pm On Jun 19, 2016
Early morning Husband
woke up and ask his wife: "Would you like to join
me for jogging?"
Wife:
"Ohh. So you mean
to say I am fat?"
Hubby:
"No. Jogging is good
for health."
Wife:
"Oh.. that means I am sick."
Hubby:
"No no. If you don't
want to get up,
then it's OK."...
Wife:
"So now you think
I am lazy, ha?"
Hubby:
"Nooo. You are misunderstanding me.
I didn't mean...."
Wife:
"Aha! So I don't understand you
because I'm an illiterate, right?"
Hubby:
"Now look I didn't say that."
Wife:
"So am I lying? "
Hubby:
I beg you pls don't
stretch it in the morning"
Wife:
"Oh, now so I am a quarrelsome nag, abi?
HUBBY:
"Ok ok.. You go off to sleep. I am going jogging alone.. happy now?."
Wife:
"You always go alone everywhere and enjoy yourself."
Hubby:
"Pls, pls. I am feeling
giddy now "
Wife:
"See? You are so selfish. Always think of yourself alone. You never think of my health."
Grrrrrr...
Husband is sitting and thinking where he went wrong.

Dedicated to all married men...
CrimeRe: Man Slaps Wife To Death In Owerri, Imo (picture) by 44chux(m): 3:10pm On Jun 19, 2016
PropertiesRe: General Topic Thread-To Discuss Anything And Everything in Building Construction by 44chux(m): 9:58am On May 18, 2016
n3xt:
Water Issue | Wrongly Sized Inspection Chamber

Here's another culprit found on a site I just diagnosed. Their fence is giving way and we found out that the inspection chamber is blocked and the water is pushing the fence.

I'll show you the fix later on this thread. I have a site inspection to carry out.
I am having something somewhat similar. My neighbours' inspection chamber is leaking and the water is flowing into mine from under the fence. Since its a commercial (tenant) house I would prefer to handle it from my side of the fence without involving my neighbours if its possible to.
PropertiesRe: General Topic Thread-To Discuss Anything And Everything in Building Construction by 44chux(m): 11:52pm On May 08, 2016
AZUH:
@abdulwatecx , the problem is this I didn't notice that the dpc of the house was low after plastering inside the house . I find out that was was coming inside each time there is little drop of rain . I talked to the engineer. He said he was sick and didn't know they only used one block for dpc . Now what should I do to stop the water entering into the rooms ? How can I increase the dpc of the house should I go for landscaping even if I know I have only one block left ?
There is this company in Lagos that claimed it could install some sort of elastomer insulation sheet to insulate my bathroom (and possibly dpc during construction) against moisture when I had the issue of moisture from adjacent bathroom wall causing peeling and discoloration of the paint in the next room.
Talk to them...

http://www.cambiellinigeria.com/
PropertiesRe: General Topic Thread-To Discuss Anything And Everything in Building Construction by 44chux(m): 7:48pm On May 08, 2016
Chekitaut:
Iron rod selling @ N125,000-130,000/ton
What would be the landing cost to Warri?
PropertiesRe: Aluminium or Stone coated Tiles? Things you should know before you roof ur house by 44chux(m): 8:40pm On May 07, 2016
pragmatistm:
Good. I'm interested in the 12V fridge. Is it available in Nigeria? How much? Can you link me up with a seller in Lagos? If possible I want to eliminate the use of my inverter and go totally DC as much as possible. If not for TV and other AC appliances, DC is just cheaper on solar in the long run.
I imagine a 12V/24V compressor on the fridge will require a bigger guage wire to prevent loses due to wire resistance. Except u get 48V+ compressor motor, it wouldn't be efficient.

Personally I prefer to import a high seer inverter a/c, fridge or washing machine unit from amazon. Start with 24 seer & You will be surprised on the efficiency
PropertiesRe: Construction/conversion Of A Bungalow Into A Duplex by 44chux(op): 8:32pm On May 07, 2016
,

PropertiesRe: Construction/conversion Of A Bungalow Into A Duplex by 44chux(op): 8:30pm On May 07, 2016
.

PropertiesRe: Construction/conversion Of A Bungalow Into A Duplex by 44chux(op): 8:28pm On May 07, 2016
,

PropertiesRe: Construction/conversion Of A Bungalow Into A Duplex by 44chux(op): 8:27pm On May 07, 2016
.

PropertiesRe: Construction/conversion Of A Bungalow Into A Duplex by 44chux(op): 2:47pm On May 07, 2016
EgunMogaji:
Okay then, good luck on your project Sir.
I crave ur indulgence, just curious to know if there is a desktop notification app that works on NL that am not aware of.
PropertiesRe: Construction/conversion Of A Bungalow Into A Duplex by 44chux(op): 2:38pm On May 07, 2016
smiley001:
Can you share the location of the project sir?
Warri Delta State
PropertiesRe: Construction/conversion Of A Bungalow Into A Duplex by 44chux(op): 2:37pm On May 07, 2016
EgunMogaji:
No a significant structure of importance or of historical significance, why wasn't it simply knocked down?
Professionals said they could save #4-5million with this.
Me: I never say NO where am not an expert.

Its a gamble shaa. Worse case I knock everything down before it gets to decking slab. So its either I save or lose 4-5mil.
PropertiesRe: Construction/conversion Of A Bungalow Into A Duplex by 44chux(op): 12:03am On May 07, 2016
johnson232:
are there no going to be pillars inside?
There will definitely be pillars according to the design.

I will upload pictures accordingly when pillars are casted