Properties › Re: Building Of My Cheap Self Cons with Pics by Akerewe(m): 3:13pm On Aug 26, 2022 |
olukaygold: 16-20 headpans will lay 100_120 6"blocks. Ah! But what if we decided to use 12 headpans or less for one bag of cement for blocks setting, any advantage over the above ratio? |
Properties › Re: Building Of My Cheap Self Cons with Pics by Akerewe(m): 3:03pm On Aug 26, 2022 |
olukaygold: We budget 2000 blocks 20 bags of cements from foundation to the roofing level,German floor,window/door linted included. Pls how many deadpan's of sand ratio to one bag of cement to achieve this 20bags to 2000 blocks laying |
Properties › Re: Building Of My Cheap Self Cons with Pics by Akerewe(m): 2:58pm On Aug 26, 2022 |
olukaygold: Placing of the pre-cast linted. Ratio for the casting 4 headpan of sharp sand and 5headpam of gravel with 1 bag of cement gave us five pre-cast linted of 4ft while above casting ratio gave us three pre-cast linted of 7ft I think the gravel should be 6 or 7 headpans as u av used 4 headpans of Sand for one bag of cement |
Investment › Re: Treasury Bills In Nigeria by Akerewe(m): 8:10pm On Aug 25, 2022 |
Allschoolsinfo: a Same here, NTB 364 tenure meant to drop on Saturday, just dropped today. I mail them and dey promised to contact cscs and it dropped just now Thanks Man |
Investment › Re: Treasury Bills In Nigeria by Akerewe(m): 10:41am On Aug 25, 2022 |
August 2028 coupon payment delayed in disbursement? Is anybody experiencing the same? |
Investment › Re: Treasury Bills In Nigeria by Akerewe(m): 3:19pm On Aug 23, 2022 |
|
Properties › Re: Abeokuta Construction Gallery by Akerewe(m): 11:55am On Aug 20, 2022 |
Biztech05: Preparing for first floor loading..... Stay tuned! Pls what are the thickness of these steel? |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 11:26am On Aug 11, 2022 |
 rotecch77: For a good and appropriate height use 2 blocks course plus the beam under slab making the height 3….. which mean from lintel top you will have about 2.5ft which is ok
Same height was used here and after Pop ceiling I still have adequate room height ( pics attached)
For the column you asked if you are using Ratio 1:2:4 you will need 1.5 approx bag of cement Means the total 16 pillar will be 16*1.5bags =24bags Add waste like 2bags or so… =26bags of cement God bless you immensely for the breakdown analysis chief, Please like how many tons of granite and Sharp sand should I b looking at in casting 16 pillars of 9", inches and all the beams? Is soft Sand necessary in mixing concrete for pillars and beams? And also likely cement bags for the upper beams @ the mixing ratio above 1:2;4 |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 11:03am On Aug 11, 2022 |
rotecch77: For a good and appropriate height use 2 blocks course plus the beam under slab making the height 3….. which mean from lintel top you will have about 2.5ft which is ok
Same height was used here and after Pop ceiling I still have adequate room height ( pics attached)
For the column you asked if you are using Ratio 1:2:4 you will need 1.5 approx bag of cement Means the total 16 pillar will be 16*1.5bags =24bags Add waste like 2bags or so… =26bags of cement Thanks chief |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 2:39pm On Aug 10, 2022 |
diordaves: I prefer a minimum of three coaches but with the way POP designing is now been implemented, I will go for four coaches for a good headroom/tall ceiling. This gives the built a grand sense of optical space and elegance. Thanks chief |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 12:54pm On Aug 10, 2022*. Modified: 2:15pm On Aug 10, 2022 |
rotecch77: You are very correct, bravo you …. if you try manage your waste very well with 25mm joint … you can achieve like 60 blocks or so Good day house, Pls how many coaches of blocks is better after lintel for a storey building? Is it the normal 2 blocks coaches or 3 coaches of blocks before decking? Also in standard, how many bags of cement will do for casting of 16pillars of 9" inches columns. |
Business › Re: Quarry price granite supply by Akerewe(m): 12:44pm On Aug 09, 2022 |
CDG1: I supply granite 24/7 and can handle as much as 2,000 tons daily.
Materials available are: Boulder,Dust,1/2inch,stonebase,3/4,5/8(3/4down) and Hardcore.
Note: I accept payment on delivery or payment before supply,I don't supply for credit for new clients.
I can also get you a truck to convey the material to any location within Lagos, Abeokuta and Ijebu Ode.
price list:
Boulder =6500/ton
Dust =2200/ton
1/2inch =7000/ton
stonebase =6500/ton
Hardcore =6500/ton
3/4 = 7000/ton
5/8(3/4down) =7000/ton
For more information, you can reach me on
08126254470 (WhatsApp) 07026691840 (calls)
Looking forward to establish partnership with you, A referral will be appreciated. How much is 3/4 down of 10tons granite to Sagamu nd is it payment on delivery? |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 5:43pm On Aug 05, 2022 |
rotecch77: My Comrade we have seen a lot in this field, May God help us all. At times when you go for cement bag counting as charges … they are ready to waste your cement I.e when a slab required 10bags of cement they will make it like 13 bags or more in other to increase there payment at the end of the daily work. Someone need to be vigilant always. Confirm! More wisdom chief |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 3:57pm On Aug 05, 2022 |
rotecch77: You are very correct, bravo you …. if you try manage your waste very well with 25mm joint … you can achieve like 60 blocks or so Like someone said above, we need someone reliable to b around our project, imagine a bricklayer decided to measure 15 headpan of sand for 1 bag of cement for setting blocks contrary to 12 headpan of sand Instructed nd when confronted he refused to measure the stipulated portion claiming it's a standard until we change it for him big time nd treating to sack him before he heed to our instructions to measure 12headpan. We need to b around because these guys are foolish pple and are ready to do away with our materials if chanced. |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 1:18pm On Aug 05, 2022 |
rotecch77: Yes, the mix ratio is vey simple my “BABA LATI bricklayer SON even know this …. More so if the sharp sand is lighter in nature , go for ratio 1:5= 10 head pan.
It’s good to follow due process, building supposed to last btw 70-100yrs or more Of course yes, practically speaking, 12 headpan of sand to 1 bag of cement will set 55 numbers of 9" inch blocks |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 9:13pm On Aug 03, 2022 |
rotecch77: Plastering and rendering stage of this project is going on .
Professional Standard gauge / mixture ratio
10mm - 15mm thickness coupled with ratio 1:5 / 1:6 Same application to our block setting ..ratio 1:6 For the block settings, u mean 1:6 x 2 = 12 head pan of sand to 1 bag of cement in all |
Investment › Re: Treasury Bills In Nigeria by Akerewe(m): 10:30am On Jul 26, 2022 |
Good day all my Oga dem dem,
Pls I need a personal experienced advice on gtbank salary advance.
If I borrow 70k from gtbank salary advance for 5 days and liquidate it with repayment, how much will my total repayment be for 5 days?
It's said to b a minimum of 30days with 29% interest rate but I just need it for 5days, will my 29% interest be calculate for 5days or am still going to pay for 30days duration if I repay it in 5days?? |
Education › Re: National Open University Of Nigeria (NOUN) Students by Akerewe(m): 10:03am On Jul 21, 2022 |
Lasisi111: To be on a safer side go and do An affidavit relating to the names on your birth cert. and all other document, then you declare how you want to be using it. If it is two names or three names you want to be using. Go and do affidavit confirming your third name is yours, simple! |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 2:32pm On Jul 12, 2022 |
Aventures: [Good day, I see we are talking about columns only what about the foundation mat. By Rule of thumb 4 nos of 16mm is required for a starter bars but don't be surprised a proper design may show you that some columns can use 12mm sufficiently. What I see here is that there is no prior structural design in this project you are building on what people say and do within that vicinity. My piece of advice pause the project engage a good structural engineer and use the out put of the design for corrections. And ensure you go for TMT Brand of reinforcement at the least.quote author=Akerewe post=114625232]
D total structure is length is 30 by 50 and the there are 16 (sixteen) columns in total. The space in between them are likely to be 10 feet maximum to the next column. As for the numbers of floors, it's just a storey building. Currently, we did 5feets for the foundation and the total foundation casted is 3feet while the remaining 2feets are visible above the foundation for continuation. The sizes between rebars should be close to 12inch nd I was told to return it to 250mm henceforth. The column itself are all 9" inches wide.
Image attached below.
Thanks in anticipation of ur response Ok thanks, I will do the needful |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 8:28pm On Jul 11, 2022 |
erico2k2: meant to be a 16MM stop the work fast, This the simple reason building collapse. Ok thanks |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 12:44pm On Jul 11, 2022 |
Aforxzy: It's not about changing the size of the reinforcements bars but the load the columns will be expected to support. The size and numbers of rebars provided for each column is a function of the load and area.
You need to let us know the numbers of floor that will be supported by the column as well as the distance between each columns. This can be determined from the structural layout of each floor and roof.
You should also seek the services of a structural engineer for an on-site assessment.
Safety first. D total structure is length is 30 by 50 and the there are 16 (sixteen) columns in total. The space in between them are likely to be 10 feet maximum to the next column. As for the numbers of floors, it's just a storey building. Currently, we did 5feets for the foundation and the total foundation casted is 3feet while the remaining 2feets are visible above the foundation for continuation. The sizes between rebars should be close to 12inch nd I was told to return it to 250mm henceforth. The column itself are all 9" inches wide. Image attached below. Thanks in anticipation of ur response
|
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 10:28pm On Jul 10, 2022 |
Enyinne: Pls dont continue as I believe 12mm is not the right one . My structural Engineer used 16mm from foundation for the same type of building and he used 12mm on the upper floor with some keep pillars using 16mm . Consult a good Engineer to avoid stories that touch Ok thanks no wahala, pls help me consult ur engineer if I can continue with 16mm because my engineer and everybody here said dat iron is ok nd thats what pple r buying as 12mm. Can I continue with 16mm |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 9:53pm On Jul 10, 2022 |
Gigaset: I'll advise you to seek another structural engineer advise before is too late Ok thanks |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 9:51pm On Jul 10, 2022 |
topsy23: Well, if the reading is still between 11.5mm - 11.7mm I believe is still okay. Since there is no regulatory body monitoring the manufacturing standard we will keep on having this issues .
That's just the truth Ok thanks, but can I continue from there with d normal/real 12mm size or higher size rod |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 6:20pm On Jul 10, 2022 |
topsy23: Did you involve engineer from the begining of the project? Because 12mm reinforcement is not the right iron for storey building. You might need to introduce another pillar using 16mm to support the existing one.
Building engineer and structural engineer are on this forum, they will throw more light on how you will go about it . Yes I involved an engineer nd I was told 12mm is ok but the welder collected money for 12mm nd got this type which 12mm was written on it's body but after d casting I decided to check d iron with caliper we discovered its below 12mm in size nd it's already casted. D engineer said that's d 12mm everyone is using but am still worried because d caliper show that it's not d full 12mm size but 12mm was written on it's body |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 6:03pm On Jul 10, 2022 |
topsy23: Are you taking the building to a storey building or the pillar is just to support the building load like parapet and roofing? To a 1 storey building (12mm was boldly written on it's body nd pple said it's what pple use everywhere for a storey building). Picture attached below. Pls advice me on if it's possible to continue with d full 12mm or preferably 16mm
|
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 1:20pm On Jul 10, 2022 |
Akerewe: Exactly what happened to me recently ooo. I paid one useless welder to buy me a 12mm rod for 5feet foundation pillars, believe me he actually bought a rod with 12mm inscription on it but after casting of the pillars am not pleased with the look of the iron Rod nd I went to that site with a caliper nd discovered that that iron is 10mm nd 12mm is written on it. Thanks to God I didn't give him the whole iron to buy for the whole beam and the long pillars. I later found out that is how they make their abnormal profits. Real 12mm is actually available, when they get to the store they demands for that to make more money. Hence forth till eternity I will buy all my iron rod myself nd always check them with a caliper b4 payment Good day engineers in the house, Pls i need professional insight as to know if I can extend or continue a building pillars with 16mm iron ROD having 12mm in the foundation after the initial error on the 12mm thickness as stated in the above write up. Thanks in anticipation of your earliest professional response |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 1:17pm On Jul 10, 2022 |
|
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 11:36am On Jul 02, 2022 |
topsy23: There is no regulatory body in this country. Reason why we are having all these.
Imported cables written 25mm if you measure it with caliper together with calculation involve , what you will get is 15.6mm .. Always tell my client that cables manufactured in Nigeria is always the best Confirm! |
Properties › Re: General Topic Thread-To Discuss Anything And Everything in Building Construction by Akerewe(m): 3:00pm On Jul 01, 2022 |
topsy23: 16mm measured 11.9mm. SON is not doing anything in this country. We don't have regulatory body Exactly what happened to me recently ooo. I paid one useless welder to buy me a 12mm rod for 5feet foundation pillars, believe me he actually bought a rod with 12mm inscription on it but after casting of the pillars am not pleased with the look of the iron Rod nd I went to that site with a caliper nd discovered that that iron is 10mm nd 12mm is written on it. Thanks to God I didn't give him the whole iron to buy for the whole beam and the long pillars. I later found out that is how they make their abnormal profits. Real12mm is actually available, when they get to the store they demands for that to make more money. Hence forth till eternity I will buy all my iron rod myself nd always check them with a caliper b4 payment |
Education › Re: National Open University Of Nigeria (NOUN) Students by Akerewe(m): 10:15pm On Jun 30, 2022 |
|
Education › Re: National Open University Of Nigeria (NOUN) Students by Akerewe(m): 3:00pm On Jun 30, 2022 |
Please is last semester 2022_1 results out? |