nonso1992:Make it easier for peeps to decide, add the cost. |
Trippledots:After years of experimentation at his workshop in the Cornish village of Callington, Jackson's eureka moment came when he developed a new formula for the electrolyte that was neither poisonous nor caustic. 'I've drunk it when demonstrating it to investors, so I can attest to the fact that it's harmless,' Jackson says. I don't know why, but I don't take dailymail publication serious. ![]() |
These guys are engineering the heck outta their harsh nature. We, in Nigeria, are still praying for good roads. WTF! |
alphabbey1:Glad you got some positive experience out of the ugly situation. |
SolnergyPower:I guess since the 150w by 4 = 600w, at 80% efficiency, i.e 80% of 600w, we have 480w. Given that the system is 12v, at bulk charging stage you should have around 14.2v for gel battery. Therefore using the Ohms law, current (I) = 480w÷14.2v = 33.80A which I guess got approximated to 35A Edit: my bad, someone already answered it. ![]() |
Same girl that falsely accused a guy of rape on twitter? https://twitter.com/ynotes_/status/1183474827941892100 |
As if the APC is doing anything to take Nigeria out of the rot they are currently in. SMH! PDP failed Nigeria. APC is CURRENTLY FAILING Nigeria. |
Topmost11:The PV Vmp is 17.5v, you are good to go. Most PWM can take up to Vmp of 24v for a 12v battery system. The PV opencircuit voltage does not necessarily have to match 12v or 24v for either of the two. |
zynzyn: helinues:Strenuous exercise gives you the appearance of an older person. Dude is super fit and possible not a day above his stated age. I congratulated myself for running less than a quarter of what he did under one hour. Lol. |
charlsecy:For optimum performance on a long distance run in a flat terrain, each runner needs to follow their own optimum pace as opposed to a fluctuating pace. Randomly fluctuating pace consumes more energy for the same finish time. Keeping awareness of the current pace at any given point consumes mental energy which could be spent elsewhere. The relatively easiest method of sticking to a known pace is to follow a runner who is known or expected to concentrate on a specific pace known in advance |
itzmoni:Luminous is a good rugged Indian inverter. The only downside is the low charging current (~13 to 15A) which shouldn't be much of an issue since the battery you have is 150ah. |
Sultty:I thought I read where the hospitals are told to treat gunshot and other victims wounded by robbers without requesting for the useless police report. Or is it only applicable for some states? http://saharareporters.com/2018/05/16/police-order-hospitals-treat-gunshot-victims-without-police-report-or-face-jail-term Sad event. https://www.luminous.com.ng/wp-content/uploads/2018/11/Capture-d%E2%80%99e%CC%81cran-2018-11-07-a%CC%80-12.17.13-2.png www.nairaland.com/attachments/11278778_images7_jpeg_jpegc250b88d3a108a1e74e6c9bf7bb78252 |
mcTrinity:You can use that. Just make sure you use the right size. |
That's a paltry sum. Not that money could bring him back. But at least they should pay an amount that may help offset some bills and other things. Damn. This is beyond sad. |
carzola:Here's the attention you ordered
|
Owodiran1:Thanks. It takes very nice pictures. |
![]() |
Demrich:Heck, there's no way you can add solar panels and charge controller to the mix and the price will still be at 340k |
zellfoxx:One of the best inverter out there. I envy the buyer ![]() |
Topmost11:It'll pay if you can get a portable clamp meter so you can successfully measure what's going on in your system. I'll recommend Uni-t clamp meters. |
Beautiful pictures, abeg which camera did you use to shoot this? Awesome. |
akpota:You can send me PM.. |
TechCapon:No one can legally force hoteliers to install cctv, but if I have one I will install it to forestall spending so much in police. All you have to do is show police the footage and continue your business. Also, if criminals know you have one, they won't try to murder anyone in your hotel. The cost of the cctv will be paid if you do not have to shut down your business to enable our ineffective police to carry out "investigation" which will end with the owner coughing out large sums of money and losing money in the period the hotel will be shut down. |
TechCapon:There are cheap cctv that 60k can get one. You can always power these cctvs with inverter. That way you have something for the police in the event of a crime. If you cannot afford these, you are better off not running such business. |
Topmost11:That will be better than a 12v system considering you plan on acquiring more panels since there is the need to add a refrigerator to the mix. |
Topmost11:I'll recommend you get a 24v inverter system so you can push above 800w panel if you get your hands on a 60A MPPT Solar Charge Controller. 12v system heavily restricts you in the case of running any load greater than 100w. I always suggest you use a 12v system for extremely light loads especially bulbs and phone charging. To enable you run more solar panels you've got to think about getting off the 12v system. |
Topmost11:You can use an external charge controller on a hybrid inverter. All you have to do is to ignore connecting the PV wires to the inverter's PV slot but rather connect it to the external charge controller's slot. I still don't understand why you should connect the 4 panels in parallel, are you running a 12v system while using a PWM charge controller? If your inverter's capacity is up to 1.5kva, it can handle most fridge in the market that is 200w or less. I was banned by the anti-spam bot yesterday in this section for reasons best known to it. I'm back. |
It's all about the money for most of these "activists" |
olaolu11:I checked on the specs of the said inverter. I noticed it has a 50A PWM solar charge controller. I can only advice you try to match the solar panel's PV voltage to the battery voltage which for example about 17Vdc at max power for 12V systems or about 28Vdc for 24V systems. You can always get another four 150w panels to increase capacity to 1200w. But left for me, I'll rather get an MPPT controller and connect all four arrays in series. Goodluck. |
olaolu11:How many batteries do you plan to use and what is the capacity of the batteries? |
durumibaka:What do you mean by this "and when battery cable is removed from cc"? Why do you have to do this? |